Engineering topics
Salvatores, M.
Publications and source records attributed to Salvatores, M..
Measurements of effective actinides neutron capture cross sections in a cadmium-filtered epithermal neutron spectrum
In this work, a total of 20 actinide samples were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL): 233 U (1), 235 U (1), 236 U (1), 238 U (1), 237 Np (2), 239 Pu (1), 240 Pu (1), 242 Pu (2), 244 Pu (2), 241 Am (2), 243 Am (2), 244 Cm (2), and 248 Cm (2). The samples were loaded in a basket containing a 1.1-mm thick cadmium filter. The presence of the filter drastically changes the neutron spectrum in the samples and accentuates the reaction rates in the resonance region. Isotopic ratios were determined using Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) that allowed inferring effective capture cross sections. Detailed best-estimate MCNP models of the experiment using ENDF/B-VII.0 nuclear data were developed to calculate the effective neutron cross sections and, subsequently, compare them with the cross sections inferred from experimental results.
Overview of the OECD-NEA Working Party on International Nuclear Data Evaluation Cooperation (WPEC)
The OECD Nuclear Energy Agency (NEA) Working Party on International Nuclear Data Evaluation Cooperation (WPEC) was established in 1989 to facilitate collaboration in nuclear data activities. Over its thirty year history, different Subgroups have been created to address topics in nearly every aspect of nuclear data, including: experimental measurements, evaluation, validation, model development, quality assurance of databases and the development of software tools. WPEC has recently completed activities on fission yield evaluation, the general nuclear database structure (GNDS) to replace the ENDF-6 format, methods to provide feedback to evaluation, studies of specific capture cross sections, new methods in thermal scattering kernel evaluation and the Collaborative International Evaluated Library Organisation (CIELO) Pilot Project. Ongoing activities in GNDS application programming interface (API) development, methods for covariance evaluation and quality assurance in nuclear data validation using the International Criticality Safety Benchmark Evaluation Project (ICSBEP) database are complemented by the work of two Expert Groups that oversee the High-Priority Request List (HPRL) for Nuclear Data and the continuous development of the GNDS. New activities on the use of integral experiments for nuclear data validation and adjustment, as well as the use of the Shielding Integral Benchmark Archive and Database (SINBAD) for validation have begun and will be coordinated alongside future Subgroups. After three decades we will review the status of WPEC, how it integrates other collections and activities organised by the NEA and how it dovetails with the initiatives of the IAEA and other bodies to effectively coordinate international activities in nuclear data.
Production and use of nuclear parameter covariance data: an overview of challenging cross cutting scientific issues
Nuclear data users’ requirements for uncertainty data started already in the seventies, when several fast reactor projects did use extensively “statistical data adjustments” to meet data improvement for core and shielding design. However, it was only ~20–30 years later that a major effort started to produce scientifically based covariance data and in particular since ~2005. Most work has been done since then with spectacular achievements and enhanced understanding both of the uncertainty evaluation process and of the data utilization in V&V. This paper summarizes some key developments and still open challenges.
Laser Ablation Positive-Ion AMS of Neutron Activated Actinides
At Argonne we have enhanced the AMS capabilities of the Argonne Tandem Linac Accelerator System (ATLAS) to attempt to minimize crosstalk between samples and to quickly move from one (M/Q) setting to another in order to make measurements on a large number of samples provided by the MANTRA (Measurement of Actinide Neutron Transmutation Rates by Accelerator mass spectrometry) project. Those improvements include the use of a picosecond laser to ablate actinide material into the source, a new 20- sample holder that can switch samples within 1-2 minutes, and a number of accelerator configuration improvements that allow quick and precise switching between species. In principle, AMS can provide production yields of actinide isotopes produced during the irradiation period at a sensitivity exceeding other mass spectrometry techniques. A total of 27 irradiated samples of a variety of actinides have been provided for measurement. We discuss our experience with these facility improvements and how well we have met our performance goals. In addition, we present preliminary results on a number of the irradiated actinide samples with this approach and compare those results to Multi- Collector ICPMS measurements.
CIELO Collaboration Summary Results: International Evaluations of Neutron Reactions on Uranium, Plutonium, Iron, Oxygen and Hydrogen
The CIELO collaboration has studied neutron cross sections on nuclides that significantly impact criticality in nuclear technologies - 235,238 U, 239 Pu, 56 Fe, 16 O and 1 H - with the aim of improving the accuracy of the data and resolving previous discrepancies in our understanding. This multi-laboratory pilot project, coordinated via the OECD/NEA Working Party on Evaluation Cooperation (WPEC) Subgroup 40 with support also from the IAEA, has motivated experimental and theoretical work and led to suites of new evaluated libraries that accurately reflect measured data and also perform well in integral simulations of criticality. This report summarizes our results on cross sections and preliminary work on covariances, and outlines plans for the next phase of this collaboration.
A Versatile Coupled Test Reactor Concept
A Versatile Coupled Test Reactor (VCTR) is a highly reconfigurable, sodium-cooled, coupled fast and thermal spectrum test reactor, which provides (1) a fast flux irradiation environment prototypical of potential fast reactor designs, (2) thermal and epithermal flux irradiation environments complementary to those of ATR and HFIR, and (3) other possibilities, including beam tubes for scientific experiments, irradiation vehicles for isotope production, etc. The ongoing design of a new versatile coupled thermal-fast test reactor at INL that can accommodate both fast and thermal irradiation, technology and safety features tests is described in this paper. A coupled reactor is defined as a reactor with two distinct spectral zones (Fast and Thermal), which are neutronically coupled to each other: some neutrons born in zone F cause fission in zone T and vice-versa. Only fast neutrons are allowed to go from one zone to the other, which is assured by a thermal neutron filter. A distinction of coupling can be made depending on the main purpose of using fuel assemblies with some level of neutron moderation (thermal zone) together with fuel assemblies with as little moderation as possible (fast zone). It can be used mainly to minimize the core power and fissile inventory, or it can be used mainly to provide additional control of the irradiation conditions in the thermal zone. The steady-state neutronics calculations were performed using the three-dimensional continuous-energy Monte Carlo reactor physics burnup calculation code Serpent2. Although, a few changes were necessary to support the Serpent code in calculating the coupling coefficients. Steady state and transient thermal analyses were performed with RELAP5-3D. RELAP5-3D is the latest in the RELAP5 code series developed at INL. One of the core configurations using only low enriched uranium fuel could provide both a high fast neutron flux and a high thermal neutron flux—respectively 3.5E15 n/s.cm2 and 1E15 n/s.cm2—in large volumes while maintaining core power below 300 MW. The use of plutonium in the fast zone provides more flexibility in fuel assembly design than when low enriched uranium is used, the designer has more degrees of freedom to work with; in particular it could provide additional control of the irradiation conditions in the thermal zone. The results showed that the current design fulfills most R&D needs requirements providing high thermal and fast fluxes and wide possibilities for diversified future reactor features test in appropriate loops, both in steady state and during transients.