Search NASA⌕ Search

Engineering topics

Sameer Kulkarni

Publications and source records attributed to Sameer Kulkarni.

Calibration of a V-Cone for Low Mass Flows For Small Core Compressor Research

Advancements in core compressor technologies are necessary for next generation, high Overall Pressure Ratio (OPR) turbofan engines. High pressure compressors (HPCs) for future engines are being designed with exit corrected mass flow rates less than 2.25 kg/s (5 lbm/s). In order to accurately measure the performance of these advanced designs, high accuracy measurements are needed in test facilities. The W7 High Speed Multistage Axial Compressor Facility at NASA Glenn Research Center has been used to acquire data for advanced compressor designs. This facility utilizes an advanced differential pressure flow meter called a V-Cone. The facility has historically tested components with physical mass flow rates in the range of 27 to 45 kg/s (60 to 100 lbm/s). As such, when the V-Cone was calibrated prior to installation, the calibrations focused on higher mass flow rates, and uncertainties in that regime range from 0.5% to 0.85%. However, for low mass flow rates under 9 kg/s (20 lbm/s), expected in tests of advanced high OPR HPCs rear stages, the uncertainties of the V-Cone exceed 2.5%. To address this, using a method similar to that utilized by the National Institute of Standards and Technology, an array of Critical Flow Venturi Nozzles (CFVs) was installed in the W7 test section and used to calibrate the V-Cone in 0.5 kg/s (1 lbm/s) increments up to 10.5 kg/s (23 lbm/s). This effort details the measurements and uncertainties associated with this calibration which resulted in a final uncertainty of the V-Cone measurements under 1%.

Measurement Uncertainty↗

Clearance Sensitivity Mitigation in Small Core Compressors

As future aircraft become lighter and more aerodynamically efficient, thrust requirements will decrease, reducing the core size of the engine. Furthermore, in the pursuit of improved fuel burn, engine overall pressure ratio and bypass ratio will increase, further driving down engine core size. These drivers together mean that the core size, or corrected mass flow rate at the compressor exit, for future single-aisle aircraft applications will shrink below 3.0 lbm/s. Traditionally, this small core compressor size is in the domain of axi-centrifugal designs, machines that are typically less efficient and limited to pressure ratios of ~25 due to stress and thermomechanical fatigue in the centrifugal impeller. In this light, NASA, Pratt & Whitney and the Raytheon Technologies Research Center embarked upon a program to develop technologies to enable an all-axial high-pressure compressor with a core size below 3.0 lbm/s and an overall pressure ratio greater than 50. One of the challenges with an all-axial high-pressure compressor at this core size is the small span at the rear of the compressor. As core size is scaled down, the rotor tip clearances do not scale with span, leading to significant efficiency penalties. This paper documents a numerical and experimental effort to mitigate this penalty through design optimization and technology insertion, enabling an estimated 5 to 10% fuel burn reduction relative to 2020 best-in-class. The experimental program consisted of two builds of a high-speed rig: a baseline build and a second build to insert technology to manage large rotor tip gap/span ratios. The results demonstrated a reduction in the sensitivity of the compressor to large clearance ratios, which would be likely at the end-of-life of a small core application. The test campaign demonstrated that, with the insertion of technology, small core compressors can maintain a similar efficiency to current best-in-class large core size compressors. In addition to advancing the state-of-the-art of technology, the program also advanced the modeling standards for multistage compressors with large clearance-to-span ratios. The validation of this approach is described in the paper.

Axial Compressors↗

Clearance Sensitivity Mitigation in Small Core Compressors

As future aircraft become lighter and more aerodynamically efficient, thrust requirements will decrease, reducing the core size of the engine. Furthermore, in the pursuit of improved fuel burn, engine overall pressure ratio and bypass ratio will increase, further driving down engine core size. These drivers together mean that the core size, or corrected mass flow rate at the compressor exit, for future single-aisle aircraft applications will shrink below 3.0 lb/s. Traditionally, this small core compressor size is in the domain of axi-centrifugal designs, machines that are typically less efficient and limited to pressure ratios of ~25 due to stress and thermomechanical fatigue in the centrifugal impeller. In this light, NASA, Pratt & Whitney and the Raytheon Technologies Research Center embarked upon a program to develop technologies to enable an all-axial high-pressure compressor with a core size below 3.0 lb/s and an overall pressure ratio greater than 50. One of the challenges with an all-axial high-pressure compressor at this core size is the small span at the rear of the compressor. As core size is scaled down, the rotor tip clearances do not scale with span, leading to significant efficiency penalties. This paper documents a numerical and experimental effort to mitigate this penalty through design optimization and technology insertion, enabling an estimated 5 to 10% fuel burn reduction relative to 2020 best-in-class. The experimental program consisted of two builds of a high-speed rig: a baseline build and a second build to insert technology to manage large rotor tip gap/span ratios. The results demonstrated a reduction in the sensitivity of the compressor to large clearance ratios, which would be likely at the end-of-life of a small core application. The test campaign demonstrated that, with the insertion of technology, small core compressors can maintain a similar efficiency to current best-in-class large core size compressors. In addition to advancing the state-of-the-art of technology, the program also advanced the modeling standards for multistage compressors with large clearance-to-span ratios. The validation of this approach is described in the paper.

Axial Compressors↗