Search NASA⌕ Search

Engineering topics

Sandler, H.

Publications and source records attributed to Sandler, H..

At least 37 records · Page 2

Effects of horizontal body casting on the baroreceptor reflex control of heart rate

The purpose of this study was to investigate the effects of long-term horizontal body position on baroreceptor reflex control of heart rate. Six male rhesus monkeys (6.2-9.4 kg) were given bolus injections of 4.0 microgram/kg, phenylephrine during each of the following conditions: awake, anesthetized (10 mg/kg ketamine HCl), and after beta-blockade (1 mg/kg propranolol HCl) before, 7, 14, and 28 days after being placed in a horizontal body cast. R-R interval vs. systolic arterial pressure was plotted, and the slope was determined by least-squares-fit linear regression. Baroreceptor slope was significantly reduced by 7 days of horizontal body position and remained attenuated throughout the 28-day restraint period both before and after beta-receptor blockade. These data are consistent with the thesis that prolonged exposure to a zero-gravity environment impairs autonomic reflex regulation of the cardiovascular system.

Billman, G. E.↗

Induced venous pooling and cardiorespiratory responses to exercise after bed rest

Venous pooling induced by a specially constructed garment is investigated as a possible means for reversing the reduction in maximal oxygen uptake regularly observed following bed rest. Experiments involved a 15-day period of bed rest during which four healthy male subjects, while remaining recumbent in bed, received daily 210-min venous pooling treatments from a reverse gradient garment supplying counterpressure to the torso. Results of exercise testing indicate that while maximal oxygen uptake endurance time and plasma volume were reduced and maximal heart rate increased after bed rest in the control group, those parameters remained essentially unchanged for the group undergoing venous pooling treatment. Results demonstrate the importance of fluid shifts and venous pooling within the cardiovascular system in addition to physical activity to the maintenance of cardiovascular conditioning.

Convertino, V. A.↗

The effects of horizontal body casting on blood volume, drug responsiveness, and +Gz tolerance in the rhesus monkey

To simulate the weightless condition, eight rhesus monkeys, instrumented with solid-state pressure transducers, were horizontally restrained in body casts for 28 days. Blood volume decreased an average of 13% after 14 days of restraint, due mainly to a drop in plasma volume. Aortic pressure and heart rate responses to norepinephrine and phenylephrine decreased after 14 days of restraint. The monkeys did not show a statistically significant decreased tolerance to a 90 deg sudden upright tilt after horizontal restraint. During the fifth week of casting, four animals were subjected to +Gz acceleration tests on a centrifuge. The acceleration tolerance of the casted monkeys was significantly reduced compared to four similarly instrumented control animals. These findings indicate that the cardiovascular deconditioning associated with simulated weightlessness results from an inability to maintain central blood volume during orthostatic stress.

Dickey, D. T.↗

Low-G simulation in mammalian research

After a review of space-flight research concerning the effects of weightlessness on mammals, the paper reviews various methods of low-G simulation. Consideration is given to water immersion; bed rest, chair rest, and confinement; immobilization; and partial body-support systems. Countermeasures to offset the effects of weightlessness are also discussed.

Sandler, H.↗

Changes in blood volume and response to vaso-active drugs in horizontally casted primates

Experiments were performed on horizontally casted primates (male rhesus monkeys) in order to note changes in blood volume caused by horizontal restraint, to compare orthostatic tolerance before and after casting using the responses to upright tilting, to begin to uncover the cardiovascular and neural mechanisms involved in deconditioning, and to compare the data with that obtained from bed-rested human subjects and from humans exposed to weightlessness. Bolus injections of norepinephrine of 2.0 microgram/kg, phenylephrine of 4.0 microgram/kg, and nitroprusside of 2.0 microgram/kg were administered; and aortic pressure and heart rate were recorded during the injections. The results indicate that the horizontally casted primate is a valid animal model for studying the effects of simulated zero-G on the human cardiovascular system.

Dickey, D. T.↗

Cardiovascular responses of the chronically instrumented monkey during simulated space flight

A pod enclosure system designed by the Environmental Physiology Laboratory at the University of California at Berkeley is found to be eminently suitable for work with monkeys. The pattern of cardiovascular activity is found to vary. In the first half of the exposure, the hourly mean values suggest an initial period of instability, most marked for heart rate, beginning at 'launch.' In the second half of the exposure, the final three days, the responses appear much more ordered, with a stable phase relationship between circadian shifts in heart rate and mean aortic pressure. Since the latter stability is more normal, the assumption is made that the animal had become adjusted to its situation. Imposition of a daily lower body negative pressure (LBNP) stress shows characteristic responses.

Mccutcheon, E. P.↗

Influences of horizontal hypokinesia on performance and circadian physiological rhythms in female humans

Eight females from 35-45 yr of age were subjected to seven days of ambulatory control, seven days of bed rest, and a five day recovery period, with 30 min of centrifugation on day seven of bedrest to determine the effects of weightlessness on the circadian rhythms of females in that age group. Heart rate and rectal temperature (RT) were monitored and each subject was tested in a flight simulator twice a day in conditions of varying levels of turbulence. The flight simulations were run during the morning and acrophase of the circadian RT and performance errors wery monitored for 6 min. No significant differences were detected in the group performance data pre-, during, and post-bedrest, although better performance in the simulator was observed after the centrifuge exposure. An RT phase shift was statistically significant between pre- and during bedrest stages.

Winget, C. M.↗

Telemetry methods for monitoring physiological parameters

The use of telemetry to monitor various physiological functions is discussed. The advantages of the technique and the parameters that it can monitor are assessed, and the main telemetry systems, including pressure telemetry, flow telemetry, and multichannel telemetry, are detailed. Human applications of implanted flow transducers, total implant versus backpack telemetry, the use of power sources and integrated circuits in telemetry, and the future prospects of the technique in hypertension treatment and research are discussed.

Fryer, T. B.↗

Effects of antiorthostatic bedrest on the cardiorespiratory responses to exercise

The cardiorespiratory changes in exercise performance induced by horizontal and antiorthostatic bed rest are compared in order to determine the physiological changes occurring in the antiorthostatic position and their degree of similarity to those observed in weightlessness. Systolic and diastolic pressures, heart rates, maximum oxygen uptake, ventilation volume during and following 5 min of submaximal exercise in the supine position and body weight and composition were determined in subjects before and following 7 days of bed rest in the horizontal or 6-deg head-down positions. Bed rest is found to result in a general decrease in exercise tolerance as indicated by cardiorespiratory parameters in both groups, with the 6-deg head-down treatment causing greater cardiovascular deconditioning. When compared with space flight data, the antiorthostatic position is shown to simulate the effects of weightlessness more effectively than horizontal bed rest

Convertino, V. A.↗

Cardiovascular regulatory response to lower body negative pressure following blood volume loss

An attempt is made to explain the cardiovascular regulatory responses to lower body negative pressure (LBNP) stress, both in the absence of and following blood or plasma volume loss, the latter being factors regularly observed with short- or long-term recumbency or weightlessness and associated with resulting cardiovascular deconditioning. Analytical expressions are derived for the responses of mean venous pressure and blood volume pooled in the lower body due to LBNP. An analysis is presented for determining the HR change due to LBNP stress following blood volume loss. It is concluded that the reduced orthostatic tolerance following long-term space flight or recumbency can be mainly attributed to blood volume loss, and that the associated cardiovascular responses characterizing this orthostatic intolerance is elicited by the associated central venous pressure response.

Shimizu, M.↗

Physiological responses of women to simulated weightlessness: A review of the first female bed-rest study

Subjects were exposed to centrifugation, to lower body negative pressure (LBNP), and to exericse stress both before and after bed rest. Areas studied were centrifugation tolerance, fluid electrolyte changes and hematology, tolerance to LBNP, physical working capacity, biochemistries, blood fibrinolytic activity, female metabolic and hormonal responses, circadian alterations, and gynecology. Results were compared with the responses observed in similarly bed-rested male subjects. The bed-rested females showed deconditioning responses similar to those of the males, although with some differences. Results indicate that women are capable of coping with exposure to weightlessness and, moreover, that they may be more sensitive subjects for evaluating countermeasures to weightlessness and developing criteria for assessing applicants for shuttle voyages.

Sandler, H.↗

Multichannel implantable telemetry system

Multiplexed biotelemetry system for animal research combines several power-saving features. Implantable sensor measures up to eight parameters simultaneously, including blood flow. Microamp transistors, switching circuits, and CMOS technology are used to lower power requirements. However, when blood flow is monitored, these measures are insufficient to reduce power enough for long-term operation from implantable primary battery.

Fryer, T. B.↗

A review of animal flight experiments

Extensive experience with biologic systems was obtained with a variety of vertebrate species over the past 18 years. Subhuman primates were precursors to man in the American space flight program; dogs and mice were animals of choice for the Soviet program. Recent attempts to use heavily instrumented animals for observations of long-term physiological effects indicate problems which must be corrected in future experiments for monitoring the effects of environmental stresses over the longer periods required for accomplishing meaningful habitation in near-Earth orbit or for travel to nearby planets.

Sandler, H.↗

Cardiovascular studies in the rhesus monkey

Criteria are given for selecting the macaca mulatta as the analogue of the human in the study of cerebral circulation, particularly the control of the cerebral vascular bed during normal and stressful conditions. Topics discussed include surgical preparation of subject; responses to changes in arterial pressure, oxygen, and carbon dioxide; innervation of cerebral vessels; cerebral flow response to acceleration; and cerebral blood flow and cerebellar stimulation.

Stone, H. L.↗

An objective determination of +Gz acceleration tolerance

Until recently, human +Gz acceleration tolerance has relied solely on subjective criteria relating to loss of vision. By use of newly developed noninvasive instrumentation using a transcutaneous Doppler flow system, objective end point criteria have been developed based on measured blood flow to the head. The system consists of miniature 8 MHz Doppler sensors (2 x 1 x 0.5 cm) placed on the forehead over both frontal branches of the temporal arteries to detect blood flow velocity from back scattered ultrasound. Its use has allowed for correlation of altered, decreased and actual reversal of eye level blood flow with subsequent central light loss. Over 100 subjects have now been studied during more than 2,000 centrifuge runs. Objective changes in temporal artery flow velocity consistently preceded visual degradation for each subject during all acceleration profiles. No subject has gone unconscious without first exhibiting a minimum 6 sec of total flow cessation. Retrograde flow followed by complete flow cessation always preceded central light loss. Results indicate that this method can be successfully used with a wide variety of tasks during exposure to +Gz acceleration. It is recommended for use during evaluation of protective maneuvers or devices on the centrifuge or during actual flight in high performance aircraft. It may also serve as a potential safety monitor during space Shuttle re-entry if there is doubt about a passenger's cardiovascular status.

Unconsciousness/prevention & control↗

Tolerance of females to +Gz centrifugation before and after bedrest

Because women may be included as passengers in the proposed Space Shuttle System, experiments were conducted on 12 female subjects aged 24-35 yr to investigate the +Gz tolerance of women and the possible degradation of this tolerance after a period of weightlessness as simulated by bedrest. Over a 1-week period, each subject was exposed to +Gz levels starting at +2 Gz and increasing by 0.5 Gz increments to a gray-out point. This point was determined by peripheral vision loss with a standard lightbar and by reverse blood flow in the temporal artery. Ultimately, each woman was subjected to three runs at the +3 Gz level for about 55 min long each, separated by 5-min rest periods. Eight subjects with the best tolerance times were selected for 14 days of bedrest in a horizontal position; the other four being ambulatory controls. Tests before bedrest, immediately following, and 5 d later showed that average +Gz tolerance decreased by 67% after bedrest.

Newsom, B. D.↗

An objective determination of /+/G-sub z acceleration tolerance

The paper describes a method for objective determination of (+)G-sub z (head-to-foot) acceleration tolerance. Using noninvasive instrumentation based on a transcutaneous Doppler flow system, objective end point criteria have been developed based on measured blood flow to the head. The system consists of miniature 8 MHz Doppler sensors placed on the forehead over both frontal branches of the temporal arteries to detect blood flow velocity from backscattered ultrasound. Over 100 subjects have been studied during more than 2000 centrifuge runs

Sandler, H.↗