Effects of rehydration on +Gz tolerance after 14-days' bed rest.

Investigation of the magnitude of reduction in human tolerance to centrifugation following 2 weeks of bed rest with moderate daily exercise. The degree of hypovolemia associated with these exposures is assessed, and the possibility to improve or to return to control levels the tolerance to acceleration forces acting in the head-to-foot direction through rehydration prior to acceleration is explored.

Greenleaf, J. E.↗

Advance techniques for monitoring human tolerance to positive Gz accelerations

Tolerance to positive g accelerations was measured in ten normal male subjects using both standard and advanced techniques. In addition to routine electrocardiogram, heart rate, respiratory rate, and infrared television, monitoring techniques during acceleration exposure included measurement of peripheral vision loss, noninvasive temporal, brachial, and/or radial arterial blood flow, and automatic measurement of indirect systolic and diastolic blood pressure at 60-sec intervals. Although brachial and radial arterial flow measurements reflected significant cardiovascular changes during and after acceleration, they were inconsistent indices of the onset of grayout or blackout. Temporal arterial blood flow, however, showed a high correlation with subjective peripheral light loss.

Pelligra, R.↗

Use of implantable telemetry systems for study of cardiovascular phenomena.

Preliminary observations of cardiovascular function have been made in four chimpanzees using multichannel implantable units. Measurements of right- and left-sided pressures were periodically made in these animals over a four-month period, including continuous observations for selected 24-hour periods. Pressures recorded with animals in an awake, unanesthetized, unrestrained state were much lower than pressures reported for restrained animals in similar situations. Diurnal variations of pressure tended to occur, but were not as clear-cut as those reported to occur for humans. The ability to implant a transmitter chronically and receive useful multichannel information in the chimpanzee encourages the future use of such implant devices as part of the control system for an artificial heart or directly for use in man.

Sandler, H.↗

An ingestible temperature-transmitter

Pill-sized transmitter measures deep body temperature in studies of circadian rhythm and indicates general health. Ingestible device is a compromise between accuracy, circuit complexity, size and transmission range.

Pope, J. M.↗

Heart catheter cable and connector

Ultraminiature catheter cables that are stiff enough for intravenous insertion yet flexible at the tip, sterilizable, and economical are fabricated entirely from commercially available parts. Assembly includes air passageway for reference pressures and coaxial cable for transmission of signals from the tip of catheter.

Harrison, D. R.↗

The use of computer graphic techniques for the determination of ventricular function.

Description of computer techniques employed to increase the speed, accuracy, reliability, and scope of angiocardiographic analyses determining human heart dimensions. Chamber margins are traced with a Calma 303 digitizer from projections of the angiographic films. The digitized margins of the ventricular images are filed in a computer for subsequent analysis. The margins can be displayed on the television screen of a graphics unit for individual study or they can be viewed in real time (or at any selected speed) to study dynamic changes in the chamber outline. The construction of three dimensional images of the ventricle is described.

Sandler, H.↗

Splanchnic blood flow and plus or minus Gx acceleration.

Experimental data show that there is a neurogenic response to acceleration stress in the front to back direction and that this response is intensified during higher accelerative forces. The afferent limb of this response is unknown but possibilities are suggested. The integrated response at high acceleration levels might serve to conserve oxygen during the stress time. The effector limb is the constriction of less critical vascular beds to preserve blood flow to the heart and brain. The concomitant increase in vagal activity causes a slowing down of the heart.

Stone, H. L.↗

+Gz tolerance after 14 days bed rest and the effects of rehydration.

Measurement of the reduction in centrifugation tolerance after two weeks of bedrest with moderate daily exercise, with an attempt to determine if rehydration improves +Gz tolerance. There were significant reductions in +Gz tolerance during bedrest periods at three acceleration levels. Rehydration resulted in a significant increase in tolerance at 2.1G but it did not restore tolerance to control levels. Rehydration did not affect tolerance at 3.2G and 3.8G.

Greenleaf, J. E.↗

Advance techniques for monitoring human tolerance to +Gz accelerations.

Standard techniques for monitoring the acceleration-stressed human subject have been augmented by measuring (1) temporal, brachial and/or radial arterial blood flow, and (2) indirect systolic and diastolic blood pressure at 60-sec intervals. Results show that the response of blood pressure to positive accelerations is complex and dependent on an interplay of hydrostatic forces, diminishing venous return, redistribution of blood, and other poorly defined compensatory reflexes.

Pelligra, R.↗

A multichannel electromagnetic flowmeter telemetry system.

An eight-channel biomedical telemetry system provides four channels of blood flow measurements in addition to blood-pressure and EKG data. Emphasis is placed on the amplifiers and signal conditioning circuitry required for interfacing of the electromagnetic flow transducers with the transmission and modulation subsystems. The large number of data channels permits measurement of flow distribution as well as total cardiac output. The batteries and electronics for four channels (blood flow) weigh about 500 g and have a volume of 250 cu cm.

Fryer, T. B.↗

Single and multichannel implanted telemetry systems.

Description of improved single-channel and multichannel telemetry systems designed for measurements of single and multiple physiological parameters, respectively, with adequate accuracy. The systems include a single-channel biopotential transmitter, a temperature transmitter, a pressure transmitter, and a multichannel transmitter for implant telemetric applications.

Sandler, H.↗