Search NASASearch

Engineering topics

Sankaran, Sankara N.

Publications and source records attributed to Sankaran, Sankara N..

Portable Microleak-Detection System

The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

Rivers, H. Kevin

Honeycomb Core Permeability Under Mechanical Loads

A method for characterizing the air permeability of sandwich core materials as a function of applied shear stress was developed. The core material for the test specimens was either Hexcel HRP-3/16-8.0 and or DuPont Korex-1/8-4.5 and was nominally one-half inch thick and six inches square. The facesheets where made of Hercules' AS4/8552 graphite/epoxy (Gr/Ep) composites and were nominally 0.059-in. thick. Cytec's Metalbond 1515-3M epoxy film adhesive was used for co-curing the facesheets to the core. The permeability of the specimens during both static (tension) and dynamic (reversed and non-reversed) shear loads were measured. The permeability was measured as the rate of air flow through the core from a circular 1-in2 area of the core exposed to an air pressure of 10.0 psig. In both the static and dynamic testing, the Korex core experienced sudden increases in core permeability corresponding to a core catastrophic failure, while the URP core experienced a gradual increase in the permeability prior to core failure. The Korex core failed at lower loads than the HRP core both in the transverse and ribbon directions.

Glass, David E.

Hydrogen transport behavior of Timetal-21S alloy

Use is made of the thermogravimetric-analysis method to ascertain the hydrogen-transport characteristics of the Timetal-21S beta-Ti alloy, at pressures of up to 50 torr over the 400-800 C temperature range. Hydrogen solubility is found to be high; the equilibrium hydrogen concentration is noted to deviate from Sievert's law at higher pressures. These deviations are likely associated with hydrogen-induced microstructural changes in the alloy, and the kinetics of hydrogen uptake reflect these changes.

Sankaran, Sankara N.

Oxidation characteristics of Ti-25Al-10Nb-3V-1Mo intermetallic alloy

Static oxidation kinetics of the super-alpha 2 titanium-aluminide alloy Ti-25Al-10Nb-3V-1Mo (at. percent) were investigated in air over the temperature range of 650 to 1000 C using thermogravimetric analysis. The oxidation kinetics were complex at all exposure temperatures and displayed up to three distinct oxidation rates. Breakaway oxidation occurred after long exposure times at high temperatures. Oxidation products were determined using x ray diffraction techniques, electron microprobe analysis, and energy dispersive x ray analysis. Oxide scale morphology was examined by scanning electron microscopy of the surfaces and cross sections of oxidized specimens. The oxides during the parabolic stages were compact and multilayered, consisting primarily of TiO2 doped with Nb, a top layer of Al2O3, and a thin bottom layer of TiN. The transition between the second and third parabolic stage was found to be linked to the formation of a TiAl layer at the oxide-metal interface. Porosity was formed during the third stage, causing degradation of the oxide and the beginning of breakaway oxidation.

Wallace, Terryl A.

Oxidation characteristics of Ti-14Al-21Nb ingot alloy

Static oxidation kinetics of Ti14Al21Nb (wt pct) ingot alloy were studied in air over the temperature interval of 649 to 1093 C in a thermogravimetric apparatus. The oxidation products were characterized by x ray diffraction, electron microprobe analysis, energy dispersive x ray analysis, and Auger electron spectroscopy. Cross-sections of the oxidized samples were also examined using light and scanning electron microscopy. The oxidation rate was substantially lower than the conventional alloys of titanium, but the kinetics displayed a complex behavior involving two or more oxidation rates depending on the temperature and duration of exposure. The primary oxide formed was TiO2, but this oxide was doped with Nb. Small amounts of Al2O3 and TiN were also present in the scale. Diffusion of oxygen into the alloy was observed and the diffusivity seemed to be dependent on the microstructure of the metal. A model was presented to explain the oxidation behavior of the alloy in terms of the reduction in the oxygen diffusivity in the oxide caused by the modification of the defect structure of TiO2 by Nb ions.

Sankaran, Sankara N.