Search NASA⌕ Search

Engineering topics

Sanyal, Oishi

Publications and source records attributed to Sanyal, Oishi.

A Self‐Consistent Model for Sorption and Transport in Polyimide‐Derived Carbon Molecular Sieve Gas Separation Membranes

Abstract Demand for energy‐efficient gas separations exists across many industrial processes, and membranes can aid in meeting this demand. Carbon molecular sieve (CMS) membranes show exceptional separation performance and scalable processing attributes attractive for important, similar‐sized gas pairs. Herein, we outline a mathematical and physical framework to understand these attributes. This framework shares features with dual‐mode transport theory for glassy polymers; however, physical connections to CMS model parameters differ from glassy polymer cases. We present evidence in CMS membranes for a large volume fraction of microporous domains characterized by Langmuir sorption in local equilibrium with a minority continuous phase described by Henry's law sorption. Using this framework, expressions are provided to relate measurable parameters for sorption and transport in CMS materials. We also outline a mechanism for formation of these environments and suggest future model refinements.

Sanyal, Oishi↗

Envisioned role of slit bypass pores in physical aging of carbon molecular sieve membranes

Carbon molecular sieve (CMS) hollow fibers remain a special class of rigid, molecular sieving membranes with unique scalability and excellent separation properties for challenging gas-pairs. These high-performing membranes are subject to moderate productivity losses and selectivity gains over time via a phenomenon typically referred to as physical aging. This article considers the role of slit bypass pores in physical aging as sensed by membrane property changes of CMS derived from aromatic polyimide precursors. Such pores are thought to be edge imperfections between adjacent ultramicroporous plates that may tighten over time, causing a reduction in penetrant diffusion coefficients. The envisioned mechanism leading to such slit bypass pores and their effects on penetrant transport are considered here from a fundamental perspective. Significantly, these slit bypass pores can be manipulated to suppress physical aging in CMS hollow fiber membranes, therefore enabling attractive long-term separation properties for multiple challenging applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Molecular Sieve Membrane Preparation by Economical Coating and Pyrolysis of Porous Polymer Hollow Fibers

Abstract Dip coating and pyrolysis processes are used to create multi‐layer asymmetric carbon molecular sieve (CMS) hollow fiber membranes with excellent gas separation properties. Coating of an economical engineered support with a high‐performance polyimide to create precursor fibers with a dense skin layer reduces material cost by 25‐fold compared to monolithic precursors or ceramic supports. CMS permeation results with CO 2 /CH 4 (50:50) mixed gas feed show attractive CO 2 /CH 4 selectivity of 58.8 and CO 2 permeance of 310 GPU at 35 °C.

Cao, Yuhe↗

Carbon Molecular Sieve Membrane Preparation by Economical Coating and Pyrolysis of Porous Polymer Hollow Fibers

Dip coating and pyrolysis processes are needed to create multi-layer asymmetric carbon molecular sieve (CMS) hollow fiber membranes with excellent gas separation properties. Coating of an economical engineered support with a high-performance polyimide to create precursor fibers with a dense skin layer reduces material cost by 25-fold compared to monolithic precursors or ceramic supports. CMS permeation results with CO 2 /CH 4 (50:50) mixed gas feed reflect attractive CO 2 /CH 4 selectivity of 58.8 and CO 2 permeance of 310 GPU at 35 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New insights into structural evolution in carbon molecular sieve membranes during pyrolysis

Carbon molecular sieve (CMS) membranes separate penetrants using size and shape-selective pores. Here, we report pyrolysis of a 6FDA:BPDA-DAM polyimide precursor between 500 and 800 °C and measure gas evolution during the CMS structural development. The CMS materials were then characterized using combined transport properties, porosimetry, FTIR, Raman spectroscopy, TGA-FTIR, WARD, and elemental analysis measurements to assess their resulting physical and chemical properties. The results support a previous vision that fragmentation of the polyimide precursor occurs to form aromatic strands that provide building blocks for the overall CMS cell structure. This fact notwithstanding, these new findings determine that constituent strands appear to be more complicated than previously suggested. An ordering process of such strands can generate a bimodal morphology comprising larger micropores with irregular cell walls containing ultramicropores. Permeability and permselectivity of the CMS for the C 2 H 4 /C 2 H 6 pair are also correlated with CMS structures based on the above characterizations. The results of this work suggest that molecular probe-based transport measurements are by far the most useful tools to study these complex, amorphous materials for molecular separation applications.

36 MATERIALS SCIENCE↗

Cause and effects of hyperskin features on carbon molecular sieve (CMS) membranes

This article considers a previously overlooked feature in carbon molecular sieve (CMS) membranes that we term a “hyperskin” present at the outermost region of dense CMS selective layers. Such a feature with much lower permeability, but similar selectivity compared to the bulk of the skin, reduces CMS hollow fiber permeance below that predicted from corresponding dense films. Effects of the hyperskin are considered for CMS hollow fibers with low skin thicknesses based on two polyimide precursors – Matrimid® and 6FDA:BPDA-DAM. Although the fundamental formation mechanism for the hyperskin feature suggests its existence on virtually all CMS membranes, its impact on transport properties is shown to differ dramatically, depending on the detailed characteristic properties of the specific CMS membrane. Indeed, for hollow fibers with very low nominal resistance (i.e. $\frac {\text{Selective layer thickness determined by SEM}}{\text{Intrinsic permeability of thick dense CMS films}}$), the observed permeance only reaches a small fraction of the predicted permeance. The selectivity between different gas penetrants, however, is not altered by the presence of this hyperskin. While identifying this issue is the major focus of this article, strategies to address this limitation, without compromising the molecular sieving properties of CMS membranes are briefly discussed.

42 ENGINEERING↗