Screening and Management of Asymptomatic Renal Stones in Astronauts

Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The true risk for renal stone formation in astronauts due to the space flight environment is unknown. Proper management of this condition is crucial to mitigate health and mission risks. The NASA Flight Medicine Clinic electronic medical record and the Lifetime Surveillance of Astronaut Health databases were reviewed. An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was also done. This work was used to develop a screening and management protocol for renal stones in astronauts that is relevant to the spaceflight operational environment. In the proposed guidelines all astronauts receive a yearly screening and post-flight renal ultrasound using a novel ultrasound protocol. The ultrasound protocol uses a combination of factors, including: size, position, shadow, twinkle and dispersion properties to confirm the presence of a renal calcification. For mission-assigned astronauts, any positive ultrasound study is followed by a low-dose renal computed tomography scan and urologic consult. Other specific guidelines were also created. A small asymptomatic renal stone within the renal collecting system may become symptomatic at any time, and therefore affect launch and flight schedules, or cause incapacitation during a mission. Astronauts in need of definitive care can be evacuated from the International Space Station, but for deep space missions evacuation is impossible. The new screening and management algorithm has been implemented and the initial round of screening ultrasounds is under way. Data from these exams will better define the incidence of renal stones in U.S. astronauts, and will be used to inform risk mitigation for both short and long duration spaceflights.

Reyes, David↗

Detection of Asymptomatic Renal Calcifications in Astronauts Using a Novel Ultrasound Protocol

Ultrasound (US) specifically looking for asymptomatic renal calcifications that may be renal stones is typically not done in the terrestrial setting. Standard abdominal US without a renal focus may discover incidental, mineralized renal material (MRM); however punctate solid areas of MRM is less than 3 mm are usually considered subclinical. Detecting these early calcifications before they become symptomatic renal stones is critical to prevent adverse medical and mission outcomes during spaceflight.

Garcia, Kathleen↗

Screening and Management of Asymptomatic Renal Stones in Astronauts

Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The true risk for renal stone formation in astronauts due to the space flight environment is unknown. Proper management of this condition is crucial to mitigate health and mission risks. The NASA Flight Medicine Clinic electronic medical record and the Lifetime Surveillance of Astronaut Health databases were reviewed. An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was also done. This work was used to develop a screening and management protocol for renal stones in astronauts that is relevant to the spaceflight operational environment. In the proposed guidelines all astronauts receive a yearly screening and post-flight renal ultrasound using a novel ultrasound protocol. The ultrasound protocol uses a combination of factors, including: size, position, shadow, twinkle and dispersion properties to confirm the presence of a renal calcification. For mission-assigned astronauts, any positive ultrasound study is followed by a low-dose renal computed tomography scan and urologic consult. Other specific guidelines were also created. A small asymptomatic renal stone within the renal collecting system may become symptomatic at any time, and therefore affect launch and flight schedules, or cause incapacitation during a mission. Astronauts in need of definitive care can be evacuated from the International Space Station, but for deep space missions evacuation is impossible. The new screening and management algorithm has been implemented and the initial round of screening ultrasounds is under way. Data from these exams will better define the incidence of renal stones in U.S. astronauts, and will be used to inform risk mitigation for both short and long duration spaceflights.

Reyes, David↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs and lower body negative pressure (LBNP) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure.

Ebert, Douglas↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, Douglas↗

Clinical Outcome Metrics for Optimization of Robust Training

The objective of this research is to develop and use clinical outcome metrics and training tools to quantify the differences in performance of a physician vs non‐physician crew medical officer (CMO) analogues during simulations.

Ebert, Doug↗

Evalution of a DE-Identification Process for Ocular Imaging

Medical privacy of NASA astronauts requires an organized and comprehensive approach when data are being made available outside NASA systems. A combination of factors, including the uniquely small patient population, the extensive medical testing done on these individuals, and the relative cultural popularity of the astronauts puts them at a far greater risk to potential exposure of personal information than the general public. Therefore, care must be taken to ensure that the astronauts' identities are concealed. Magnetic Resonance Imaging (MRI) medical data is a recent source of interest to researchers concerned with the development of Visual Impairment due to Intracranial Pressure (VIIP) in the astronaut population. Each vision MRI scan of an astronaut includes 176 separate sagittal images that are saved as an "image series" for clinical use. In addition to the medical information these image sets provide, they also inherently contain a substantial amount of non-medical personally identifiable information (PII) such as-name, date of birth, and date of exam. We have shown that an image set of this type can be rendered, using free software, to give an accurate representation of the patient's face. This currently restricts NASA from dispensing MRI data to researchers in a deidentified format. Automated software programs, such as the Brain Extraction Tool, are available to researchers who wish to de-identify MRI sagittal brain images by "erasing" identifying characteristics such as the nose and jaw on the image sets. However, this software is not useful to NASA for vision research because it removes the portion of the images around the eye orbits, which is the main area of interest to researchers studying the VIIP syndrome. The Lifetime Surveillance of Astronaut Health program has resolved this issue by developing a protocol to de-identify MRI sagittal brain images using Showcase Premier, a DICOM (Digital Imaging and Communications in Medicine) software package. The software allows manual editing of one image from a patient's image set to be automatically applied to the entire image series. This new approach would allow a new level of access to untapped medical imaging data relating to VIIP that can be utilized by researchers while protecting the privacy of the astronauts. In the next step toward finalizing this technique, NASA clinical radiology consultants will test the images to verify removal of all metadata and PII.

LaPelusa, Michael B.↗

Optic Nerve Sheath Diameter: Translating a Terrestrial Focused Technique into a Clinical Monitoring Tool for Spaceflight

Ultrasonography is increasingly used to quickly measure optic nerve sheath diameter (ONSD) when increased intracranial pressure (ICP) is suspected. NASA Space and Clinical Operations Division has been using ground and on‐orbit ultrasound since 2009 as a proxy for ICP in non‐acute monitoring for space medicine purposes. In the terrestrial emergency room population, an ONSD greater than 0.59 cm is considered highly predictive of elevated intracranial pressure. However, this cut‐off limit is not applicable to the spaceflight setting since over 50% of US Operating Segment (USOS) astronauts have an ONSD greater than 0.60 cm even before launch. Crew Surgeon clinical decision‐making is complicated by the fact that many astronauts have history of previous spaceflights. Our data characterize the distribution of baseline ONSD in the astronaut corps, its longitudinal trends in long‐duration spaceflight, and the predictive power of this measure related to increased ICP outcomes.

Mason, Sara↗

Monitoring for Renal Stone Recurrence in Astronauts With History of Stone

After an initial stone episode persons are at increased risk for future stone formation. A systematic approach is required to monitor the efficacy of treatment and preventive measures, and to assess the risk of developing new stones. This is important for persons working in critical jobs or austere environments, such as astronauts. A literature review of the current standards of care for renal stone monitoring and imaging was done. Military and civil aviation standards were also reviewed, as well as the medical precedents from the space program. Additionally, a new, more effective, renal stone ultrasound protocol has been developed. Using this work, a monitoring algorithm was proposed that takes into consideration the unique mission and operational environment of spaceflight. The approach to imaging persons with history of renal stones varies widely in the literature. Imaging is often done yearly or biannually, which may be too long for mission critical personnel. In the proposed algorithm astronauts with a history of renal stone, who may be under consideration for assignment, are imaged by a detailed, physiciandriven, ultrasound protocol. Unassigned personnel are monitored by yearly ultrasound and urine studies. Any positive ultrasound study is then followed by low-dose renal computed tomography scan. Other criteria are also established. The proposed algorithm provides a balanced approach between efficacy and reduced radiation exposure for the monitoring of astronauts with a renal stone history. This may eventually allow a transition from a risk-averse, to a risk-modifying approach that can enable continued service of individuals with history of renal stone that have adequately controlled risk factors.

Reyes, David P.↗

Facial Soft Tissue Measurement in Microgravity-induces Fluid Shifts

Fluid shifts are a well‐known phenomenon in microgravity, and one result is facial edema. Objective measurement of tissue thickness in a standardized location could provide a correlate with the severity of the fluid shift. Previous studies of forehead tissue thickness (TTf) suggest that when exposed to environments that cause fluid shifts, including hypergravity, head‐down tilt, and high‐altitude/lowpressure, TTf changes in a consistent and measurable fashion. However, the technique in past studies is not well described or standardized. The International Space Station (ISS) houses an ultrasound (US) system capable of accurate sub‐millimeter measurements of TTf. We undertook to measure TTf during long‐duration space flight using a new accurate, repeatable and transferable technique. Methods: In‐flight and post‐flight B‐mode ultrasound images of a single astronaut's facial soft tissues were obtained using a Vivid‐q US system with a 12L‐RS high‐frequency linear array probe (General Electric, USA). Strictly mid‐sagittal images were obtained involving the lower frontal bone, the nasofrontal angle, and the osseo‐cartilaginous junction below. Single images were chosen for comparison that contained identical views of the bony landmarks and identical acoustical interface between the probe and skin. Using Gingko CADx DICOM viewing software, soft tissue thickness was measured at a right angle to the most prominent point of the inferior frontal bone to the epidermis. Four independent thickness measurements were made. Conclusions: Forehead tissue thickness measurement by ultrasound in microgravity is feasible, and our data suggest a decrease in tissue thickness upon return from microgravity environment, which is likely related to the cessation of fluid shifts. Further study is warranted to standardize the technique with regard to the individual variability of the local anatomy in this area.

Marshburn, Thomas↗

Optic Nerve Sheath Diameter: Translating a Terrestrial Focused Technique Into a Clinical Monitoring Tool for Space Flight

Emergency medicine physicians recently adopted the use of ultrasonography to quickly measure optic nerve sheath diameter (ONSD) as concomitant with increased intracranial pressure. NASA Space and Clinical Operations Division has been using ground and on-orbit ultrasound capabilities since 2009 to consider this anatomical measure as a proxy for intracranial pressure in the microgravity environment. In the terrestrial emergency room population, an ONSD greater than 0.59 cm is considered highly predictive of elevated intracranial pressure. However, this cut-off limit is not applicable to the spaceflight setting since over 50% of US Operating Segment (USOS) astronauts have an ONSD greater than 0.60 cm even before missions. Crew Surgeon clinical decision-making is complicated by the fact that many astronauts have history of previous spaceflights. Data will be presented characterizing the distribution of baseline ONSD in the astronaut corps, longitudinal trends in-flight, and the predictive power of this measure related to increased intracranial pressure outcomes.

Mason, Sara S.↗

Smart Ultrasound Remote Guidance Experiment (SURGE)- Concept of Operations Evaluation for Using Remote Guidance Ultrasound for Planetary Space Flight

Introduction Use of remote guidance (RG) techniques aboard the International Space Station (ISS) has enabled astronauts to collect diagnostic-level ultrasound images. Exploration class missions will require this cohort of (typically) non-formally trained sonographers to operate with greater autonomy given the longer communication delays (2 seconds for ISS vs. >6 seconds for missions beyond the Moon) and communication blackouts. To determine the feasibility and training requirements for autonomous ultrasound image collection by non-expert ultrasound operators, ultrasound images were collected from a similar cohort using three different image collection protocols: RG only, RG with a computer-based learning tool (LT), and autonomous image collection with LT. The groups were assessed for both image quality and time to collect the images. Methods Subjects were randomized into three groups: RG only, RG with LT, and autonomous with LT. Each subject received 10 minutes of standardized training before the experiment. The subjects were tasked with making the following ultrasound assessments: 1) bone fracture and 2) focused assessment with sonography in trauma (FAST) to assess a patient s abdomen. Human factors-related questionnaire data were collected immediately after the assessments. Results The autonomous group did not out-perform the two groups that received RG. The mean time for the autonomous group to collect images was less than the RG groups, however the mean image quality for the autonomous group was less compared to both RG groups. Discussion Remote guidance continues to produce higher quality ultrasound images than autonomous ultrasound operation. This is likely due to near-instant feedback on image quality from the remote guider. Expansion in communication time delays, however, diminishes the capability to provide this feedback, thus requiring more autonomous ultrasound operation. The LT has the potential to be an excellent training and coaching component for autonomous ultrasound image collection during exploration missions.

Hurst, Victor, IV↗

Smart Ultrasound Remote Guidance Experiment (SURGE) Preliminary Findings

To date, diagnostic quality ultrasound images were obtained aboard the International Space Station (ISS) using the ultrasound of the Human Research Facility (HRF) rack in the Laboratory module. Through the Advanced Diagnostic Ultrasound in Microgravity (ADUM) and the Braslet-M Occlusion Cuffs (BRASLET SDTO) studies, non-expert ultrasound operators aboard the ISS have performed cardiac, thoracic, abdominal, vascular, ocular, and musculoskeletal ultrasound assessments using remote guidance from ground-based ultrasound experts. With exploration class missions to the lunar and Martian surfaces on the horizon, crew medical officers will necessarily need to operate with greater autonomy given communication delays (round trip times of up to 5 seconds for the Moon and 90 minutes for Mars) and longer periods of communication blackouts (due to orbital constraints of communication assets). The SURGE project explored the feasibility and training requirements of having non-expert ultrasound operators perform autonomous ultrasound assessments in a simulated exploration mission outpost. The project aimed to identify experience, training, and human factors requirements for crew medical officers to perform autonomous ultrasonography. All of these aims pertained to the following risks from the NASA Bioastronautics Road Map: 1) Risk 18: Major Illness and Trauna; 2) Risk 20) Ambulatory Care; 3) Risk 22: Medical Informatics, Technologies, and Support Systems; and 4) Risk 23: Medical Skill Training and Maintenance.

Hurst, Victor↗

Second Harmonic Imaging improves Echocardiograph Quality on board the International Space Station

Ultrasound (US) capabilities have been part of the Human Research Facility (HRF) on board the International Space Station (ISS) since 2001. The US equipment on board the ISS includes a first-generation Tissue Harmonic Imaging (THI) option. Harmonic imaging (HI) is the second harmonic response of the tissue to the ultrasound beam and produces robust tissue detail and signal. Since this is a first-generation THI, there are inherent limitations in tissue penetration. As a breakthrough technology, HI extensively advanced the field of ultrasound. In cardiac applications, it drastically improves endocardial border detection and has become a common imaging modality. U.S. images were captured and stored as JPEG stills from the ISS video downlink. US images with and without harmonic imaging option were randomized and provided to volunteers without medical education or US skills for identification of endocardial border. The results were processed and analyzed using applicable statistical calculations. The measurements in US images using HI improved measurement consistency and reproducibility among observers when compared to fundamental imaging. HI has been embraced by the imaging community at large as it improves the quality and data validity of US studies, especially in difficult-to-image cases. Even with the limitations of the first generation THI, HI improved the quality and measurability of many of the downlinked images from the ISS and should be an option utilized with cardiac imaging on board the ISS in all future space missions.

Garcia, Kathleen↗

Development and Operation of a Modern Information Portal for the ISS Medical Groups

This viewgraph presentation begins with a review of some of the problems inherent in running medical services for the International Space Station. Part of the solution for the problems is the development of the information portal for the ISS medical groups. The presentation shows the tools that have been developed to assist in collaboration for the medical services, the security system and the capabilities of the portal.

Damann, V.↗

Evaluating Trauma Sonography for Operational Use in the Microgravity Environment

Sonography is the only medical imaging modality aboard the ISS, and is likely to remain the leading imaging modality in future human space flight programs. While trauma sonography (TS) has been well recognized for terrestrial trauma settings, the technique had to be evaluated for suitability in space flight prior to adopting it as an operational capability. The authors found the following four-phased evaluative approach applicable to this task: 1) identifying standard or novel terrestrial techniques for potential use in space medicine; 2) developing and testing these techniques with suggested modifications on the ground (1g) either in clinical settings or in animal models, as appropriate; 3) evaluating and refining the techniques in parabolic flight (0g); and 4) validating and implementing for clinical use in space. In Phase I of the TS project, expert opinion and literature review suggested TS to be a potential screening tool for trauma in space. In Phase II, animal models were developed and tested in ground studies, and clinical studies were carried out in collaborating trauma centers. In Phase III, animal models were flight-tested in the NASA KC-135 Reduced Gravity Laboratory. Preliminary results of the first three phases demonstrated potential clinical utility of TS in microgravity. Phase IV studies have begun to address crew training issues, on-board imaging protocols, and data transfer procedures necessary to offer the modified TS technique for space use.

Kirkpatrick, Andrew W.↗