Search NASA⌕ Search

Engineering topics

Sarlioglu, Bulent

Publications and source records attributed to Sarlioglu, Bulent.

At least 19 records

Electric Motor Thermal Management

The poster reports the accomplishments of EDT-Electric Motor Thermal Management consortium project for 2024 VTO Annual Merit Review (AMR). The overall aims of the project are to support research enabling compact, reliable, low-cost, and efficient electric machines aligned with roadmap research areas; to collaborate with ORNL, Ames, and SNL to provide motor thermal analysis support, reliability evaluation, and material measurements on related motor research at national laboratories; and collaborate with university partners including Georgia Institute of Technology and University of Wisconsin Madison to support university-led motor thermal management research efforts.

ADVANCED PROPULSION SYSTEMS↗

PWM for Simultaneous Minimization of Switching Losses and CM Voltage in Current Source Inverters

This article proposes a new pulsewidth modulation (PWM) scheme that reduces common-mode (CM) voltage and switching losses simultaneously in CSI. The proposed PWM [i.e., reduced voltages PWM (RVM)] reduces CM voltages and switching losses by selecting the optimal zero current vector and PWM sequence based on the CSI output voltage conditions. This article also proves the proposed RVM achieves both objectives (i.e., reduced CM voltage and switching losses) simultaneously for all CSI operating conditions without compromising the other objective. The proposed RVM inherently achieves zero-voltage switching (ZVS) conditions during the zero current vector transitions, further reducing the switching losses. Experimental results demonstrate significant reductions in CM voltage, reaching up to approximately 95%, accompanied by an increase of up to about 5.5% in CSI efficiency across a wide operating range compared to alternative PWM methods, confirming the predicted advantages of the proposed RVM.

42 ENGINEERING↗

Comprehensive Comparative Analysis: VSI-based vs. CSI-based Motor Drive Systems with Sinusoidal Output Voltage

The emergence of wide-bandgap (WBG) power devices opens opportunities for current source inverters (CSIs) to provide a promising alternative drive configuration for motor drive applications. The sinusoidal output voltage of CSI offers significant advantages for numerous motor drive applications, including reducing the risks associated with motor terminal overvoltages and bearing discharge currents. This paper compares the performance of CSIs and voltage source inverters (VSIs) with the same performance capabilities. More specifically, sine filters are added to the VSI output terminals to match the CSI performance, and a front-end boost converter is added to the VSI to match the CSI’s voltage-boost capability. The results show that the CSI active components require 48% less volume than the VSI, combined with other performance advantages that make it an appealing candidate for some future motor drive applications.

current source inverter, motor drive system, passi↗

Electric Motor Thermal Management

During FY 2022, NREL efforts focused on supporting collaborations with external research partners within the Electric Drive Technologies research consortium. The poster highlights collaborations with SNL, ORNL, and Georgia Tech. The collaboration with SNL utilized NREL's experimental capabilities to mechanically characterize SNL-provided material samples for motor applications. The collaboration with ORNL supported efforts to refine the design of a high-speed, non-heavy-rare-earth outer-rotor motor. The collaboration with Georgia Tech focused on a novel cooling technique for electric machines. NREL supported the effort by leading the thermal analysis and design of advanced machines.

ADVANCED PROPULSION SYSTEMS↗

Design and Comparison of Surface Inset Permanent Magnet Machine and Surface Permanent Magnet Machine without Heavy Rare Earth Magnets for Traction Applications

This paper presents two machine designs: a surface inset permanent magnet (SIPM) machine and a surface permanent magnet (SPM) machine, both without heavy rare-earth magnets, that achieve 50 kW/L active power density and a constant-power speed ratio of 3 for EV traction applications. Compared to surface PM machines, SIPM machines do not require a special containment sleeve to hold the magnets in place at high speeds, provided that the rotor laminations are carefully designed together with the magnet mounting configuration to ensure the rotor’s structural integrity. Comparisons between the SPM and SIPM machines sharing the same stator, same current level, and same power speed envelope are presented. Both deliver very similar performance characteristics, but the SIPM machine’s simpler magnet containment configuration may give it an advantage in terms of reduced material and manufacturing costs.

42 ENGINEERING↗

Thermal Analysis of Liquid and Air Cooling of High-Power-Density Integrated Motor Drives

Thermal management is a crucial aspect in the design of motor and drive systems. This paper introduces a coordinated cooling approach utilizing both liquid and air to enhance the integrated motor drive's power density. The proposed solution incorporates a shared water jacket to cool both the machine and power electronics, combined with forced air ventilation for the end windings and rotor. This approach is structurally simpler, less expensive, and more effective than conventional non-interacting cooling schemes. The paper addresses the modeling of key thermal features and nonlinearities including material anisotropy, contact thermal resistance, and uneven winding loss distributions. In addition, this study utilizes a more detailed model of the loss distribution among the winding turns in each slot that delivers a higher level of accuracy. Finite Element Analysis (FEA) results demonstrate the effectiveness of the integrated cooling system for efficiently cooling the designed integrated motor drive system.

42 ENGINEERING↗

Comprehensive Efficiency Analysis of Seven-Switch Current-Source Inverter Based on Voltage-Boost Function and Genetic Algorithm

This paper investigates the voltage-boost features of the emerging seven-switch current-source inverter (H7-CSI) to improve the efficiency of the CSI-based motor drive system. The switching transient and power loss model of the H7-CSI topology during voltage-boost operation are analyzed in detail. The effects of the boost function on the switching and conduction loss of the H7-CSI topology are investigated. A genetic algorithm has been introduced that makes it possible to optimize the H7-CSI’s modulation index to minimize its power loss. Experimental results for the H7-CSI unit show that this optimization can reduce the power loss by 10.6%.

42 ENGINEERING↗

Alternative Vector PWM for CSI Common-Mode Voltage Reduction During Voltage-Boost Operation with Low Modulation Index

This paper proposes a new pulse-width modulation (PWM) scheme named alternative vector PWM (AVM) algorithm that reduces the common-mode voltage (vCM) generated by a 3-phase current source inverter (CSI) during operation within a portion of its voltage-boost regime when the CSI’s modulation index is below 1/3–√(=0.5774). Three different active current vector pairs (one conventional pair with adjacent active current vectors and two proposed pairs with non-adjacent active current vectors) are used to reduce vCM based on the CSI’s output voltage conditions. Experimental results confirm significant reductions in major vCM spectral components by up to approx. 85% between the 3rd harmonic of the fundamental frequency and the CSI’s PWM frequency, validating the advantages of the proposed AVM algorithm over the conventional PWM.

42 ENGINEERING↗

Topological Equivalence of VSI and CSI Commutation Cells and Its Application to Switching Resonance Analysis and Damper Design

This paper proposes the concept of the topological equivalence between the commutation cells of a voltage source inverter (VSI) and a current source inverter (CSI) using duality and equivalent circuit transformation techniques. A switching resonance of CSI is analyzed and an effective three-phase RC damper is derived from the dc-link RC damper of VSIs based on the topological equivalence of the VSI and CSI commutation cells. Furthermore, a new three-phase RC damper design framework utilizing the topological equivalence is proposed. Here, experimental results verify that the proposed three-phase RC damper design for CSI significantly reduces the switching resonance and improves the CSI’s output waveform total harmonics distortions (THDs).

42 ENGINEERING↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

ADVANCED PROPULSION SYSTEMS↗

Balanced current-source inverter

A switching circuit for a current source inverter includes a first inverter leg, a second inverter leg, and a controller. The first inverter leg includes a first reverse-voltage-blocking (RB) switch, a second RB switch, and a third RB switch that are connected in series between a first bus line and a second bus line. The second inverter leg includes a fourth RB switch, a fifth RB switch, and a sixth RB switch are connected in series between the first bus line and the second bus line. The controller is configured to control a switch between an on-state and an off-state for each RB switch. When in the on-state, a reverse voltage is blocked by a respective RB switch, and a current with a positive polarity is conducted through the respective RB switch. When in the off-state, a voltage and the current are blocked by the respective RB switch.

Jahns, Thomas Merlin↗

Comparative Investigation of Current-Source Inverters using SiC Discrete Devices and Power Modules

The purpose of this paper is to investigate the impact of the SiC device packages on the commutation performance characteristics of current-source inverters (CSIs). The parasitic components in the CSI current commutation loop between the two-phase legs and output capacitors have a significant impact on the high-frequency performance of the SiC devices. To meet the elevated current requirements of high-power CSIs, it is often necessary to connect multiple discrete devices in parallel which increases the current commutation loop length. The selection of compact high-power SiC MOSFET and Schottky diode modules instead of discrete devices can be highly desirable to reduce the loop inductance and improve the system performance and power density. Two CSI benchtop prototype units, one with SiC discrete devices and the other with power modules, have been designed and tested, and the performances of the two CSIs are compared. The CSI with SiC power modules significantly reduces the inverter volume and lowers the parasitic inductance by 60% and the voltage ripple amplitude by 20% compared to the CSI unit with discrete devices.

42 ENGINEERING↗

A High-Accuracy Power Loss Model of SiC MOSFETs in Current Source Inverter Considering Current Commutation and Parasitic Parameters

Power loss estimation of power electronic devices is important to the efficiency optimization of motor drives used in many applications. However, most existing simplified power loss models of silicon carbide (SiC) MOSFETs are not sufficiently accurate due to their neglect of parasitic parameters in the current commutation loop. In addition, the loss model of the voltage source inverter (VSI) cannot be directly applied to the current source inverter (CSI) because of differences between their commutation loops. First, the commutation processes for VSIs and CSIs are compared. The voltage and current trajectories of SiC MOSFETs in the switching transition of a CSI-based motor drive system are analyzed in detail. Based on these results, the conduction and switching losses of SiC MOSFETs in CSIs are modeled considering the current commutation details. In addition, the proposed analytical model includes parasitic inductances and capacitances in the current commutation loop. Experimental results have verified that the proposed power loss model delivers higher accuracy loss predictions than the conventional loss model.

current commutation, current source inverter, powe↗

Thermal Stress Reduction in Power Switching Devices Using Distributed Loss PWM Concept for Current Source Inverters

A new modulation scheme is proposed for current source inverters (CSIs) that reduces the variation and peak junction temperature in the CSIs' power devices. The distributed loss pulse-width modulation (DLM) concept is introduced and applied to traditional space vector modulation methods to develop modified modulation schemes that reduce the thermal stress on power devices. The device junction temperatures resulting from conventional and DLM schemes are compared. Simulation and experimental results confirm that the proposed DLM concept reduces thermal stress on the devices while maintaining the same high output current waveform quality compared to traditional CSI modulation schemes. The CSI power device lifetime (i.e., the number of cycles to failure) are estimated using the simulation and experimental results. The proposed DLM significantly increases the device lifetime (by 5 to 6 times) by reducing the junction temperature variation compared to the conventional modulations.

42 ENGINEERING↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Current source inverter with bi-directional switches

A switching circuit includes a diode, a semiconductor switch, and a first bidirectional switch. The semiconductor switch is configured to conduct a first current from a second terminal to a third terminal of the semiconductor switch when a first on-state signal is sent to a first terminal of the semiconductor switch. An anode of the diode is connected to the second terminal of the semiconductor switch, and a cathode of the diode is connected to the third terminal of the semiconductor switch. The first bidirectional switch includes a first terminal, a second terminal connected to the anode of the diode, and a third terminal and is configured to conduct a second current from the second terminal to the third terminal or from the third terminal to the second terminal when a second on-state signal is sent to the first terminal of the first bidirectional switch.

Dai, Hang↗