Search NASA⌕ Search

Engineering topics

Sarychev, Michael

Publications and source records attributed to Sarychev, Michael.

D0 Decommissioning: Storage of depleted uranium modules inside D0 calorimeters after the termination of D0 experiment

Dzero liquid Argon calorimeters contain hadronic modules made of depleted uranium plates. After the termination of D0 detector's operation, liquid Argon will be transferred back to Argon storage Dewar, and all three calorimeters will be warmed up. At this point, there is no intention to disassemble the calorimeters. The depleted uranium modules will stay inside the cryostats. Depleted uranium is a by-product of the uranium enrichment process. It is slightly radioactive, emits alpha, beta and gamma radiation. External radiation hazards are minimal. Alpha radiation has no external exposure hazards, as dead layers of skin stop it; beta radiation might have effects only when there is a direct contact with skin; and gamma rays are negligible - levels are extremely low. Depleted uranium is a pyrophoric material. Small particles (such as shavings, powder etc.) may ignite with presence of Oxygen (air). Also, in presence of air and moisture it can oxidize. Depleted uranium can absorb moisture and keep oxidizing later, even after air and moisture are excluded. Uranium oxide can powder and flake off. This powder is also pyrographic. Uranium oxide may create health problems if inhaled. Since uranium oxide is water soluble, it may enter the bloodstream and cause toxic effects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

D0 Silicon Detector Moisture Injection

The system is designed to increase water content in dry air used to purge DO silicon detector. Moisture will not be added to fiber tracker purge. Currently, the air is dried to -85 deg. C (-120 deg. F). The goal is to increase Dew point of the air to about -40 C to -20 C range. This is done by redirecting a portion of dry air (about 10%) through a bubbler, and then return it to main stream. Air is taken upstream of PRV-6231-I pressure regulator (90 psi) and going to the bubbler (BU-6404-I) through the flow regulator, permitting controlled moisture addition. Water separator (FI-6411-I) and auto drain (MV-6412-I) prevent water break-trough in case of bubbler's overflowing. Moist air (saturated with water) is returned to main flow of purge air downstream of PRV-6231-I (55 psi). Water is taken from DO LCW system. Initial pressure of 110 psi is reduced to 60 psi (PRV-6421-I); expected fill rate is 1 Umin. with 55 psi in the bubbler.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗