Search NASA⌕ Search

Engineering topics

Sato, M

Publications and source records attributed to Sato, M.

At least 19 records

SU-F-J-131: Reproducibility of Positioning Error Due to Temporarily Indwelled Urethral Catheter for Urethra-Sparing Prostate IMRT

Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostate at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by post-indwelled CT images.

60 APPLIED LIFE SCIENCES↗

SU-F-T-479: Estimation of the Accuracy in Respiratory-Gated Radiotherapy

Purpose: Irregular respiratory patterns affects dose outputs in respiratorygated radiotherapy and there is no commercially available quality assurance (QA) system for it. We designed and developed a patient specific QA system for respiratory-gated radiotherapy to estimate irradiated output. Methods: Our in-house QA system for gating was composed of a personal computer with the USB-FSIO electronic circuit connecting to the linear accelerator (ONCOR-K, Toshiba Medical Systems). The linac implements a respiratory gating system (AZ-733V, Anzai Medical). During the beam was on, 4.2 V square-wave pulses were continually sent to the system. Our system can receive and count the pulses. At first, our system and an oscilloscope were compared to check the performance of our system. Next, basic estimation models were generated when ionization-chamber measurements were performed in gating using regular sinusoidal wave patterns (2.0, 2.5, 4.0, 8.0, 15 sec/cycle). During gated irradiation with the regular patterns, the number of the pulses per one gating window was measured using our system. Correlation between the number of the pulses per one gating and dose per the gating window were assessed to generate the estimation model. Finally, two irregular respiratory patterns were created and the accuracy of the estimation was evaluated. Results: Compared to the oscilloscope, our system worked similarly. The basic models were generated with the accuracy within 0.1%. The results of the gated irradiations with two irregular respiratory patterns show good agreement within 0.4% estimation accuracy. Conclusion: Our developed system shows good estimation for even irregular respiration patterns. The system would be a useful tool to verify the output for respiratory-gated radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-J-86: Functional Conformal Planning for Stereotactic Body Radiation Therapy with CT-Pulmonary Ventilation Imaging

Purpose: To evaluate the functional planning using CT-pulmonary ventilation imaging for conformal SBRT. Methods: The CT-pulmonary ventilation image was generated using the Jacobian metric in the in-house program with the NiftyReg software package. Using the ventilation image, the normal lung was split into three lung regions for functionality (high, moderate and low). The anatomical plan (AP) and functional plan (FP) were made for ten lung SBRT patients. For the AP, the beam angles were optimized with the dose-volume constraints for the normal lung sparing and the PTV coverage. For the FP, the gantry angles were also optimized with the additional constraint for high functional lung. The MLC aperture shapes were adjusted to the PTV with the additional 5 mm margin. The dosimetric parameters for PTV, the functional volumes, spinal cord and so on were compared in both plans. Results: Compared to the AP, the FP showed better dose sparing for high- and moderate-functional lungs with similar PTV coverage while not taking care of the low functional lung (High:−12.9±9.26% Moderate: −2.0±7.09%, Low: +4.1±12.2%). For the other normal organs, the FP and AP showed similar dose sparing in the eight patients. However, the FP showed that the maximum doses for spinal cord were increased with the significant increment of 16.4Gy and 21.0Gy in other two patients, respectively. Because the beam direction optimizer chose the unexpected directions passing through the spinal cord. Conclusion: Even the functional conformal SBRT can selectively reduce high- and moderatefunctional lung while keeping the PTV coverage. However, it would be careful that the optimizer would choose unexpected beam angles and the dose sparing for the other normal organs can be worse. Therefore, the planner needs to control the dose-volume constraints and also limit the beam angles in order to achieve the expected dose sparing and coverage.

60 APPLIED LIFE SCIENCES↗

SU-E-T-423: Fast Photon Convolution Calculation with a 3D-Ideal Kernel On the GPU

Purpose: The calculation time is a trade-off for improving the accuracy of convolution dose calculation with fine calculation spacing of the KERMA kernel. We investigated to accelerate the convolution calculation using an ideal kernel on the Graphic Processing Units (GPU). Methods: The calculation was performed on the AMD graphics hardware of Dual FirePro D700 and our algorithm was implemented using the Aparapi that convert Java bytecode to OpenCL. The process of dose calculation was separated with the TERMA and KERMA steps. The dose deposited at the coordinate (x, y, z) was determined in the process. In the dose calculation running on the central processing unit (CPU) of Intel Xeon E5, the calculation loops were performed for all calculation points. On the GPU computation, all of the calculation processes for the points were sent to the GPU and the multi-thread computation was done. In this study, the dose calculation was performed in a water equivalent homogeneous phantom with 150{sup 3} voxels (2 mm calculation grid) and the calculation speed on the GPU to that on the CPU and the accuracy of PDD were compared. Results: The calculation time for the GPU and the CPU were 3.3 sec and 4.4 hour, respectively. The calculation speed for the GPU was 4800 times faster than that for the CPU. The PDD curve for the GPU was perfectly matched to that for the CPU. Conclusion: The convolution calculation with the ideal kernel on the GPU was clinically acceptable for time and may be more accurate in an inhomogeneous region. Intensity modulated arc therapy needs dose calculations for different gantry angles at many control points. Thus, it would be more practical that the kernel uses a coarse spacing technique if the calculation is faster while keeping the similar accuracy to a current treatment planning system.

60 APPLIED LIFE SCIENCES↗

Electron density measurement of cesium seeded negative ion source by surface wave probe

Electron density measurements of a large-scaled negative ion source were carried out with a surface wave probe. By comparison of the electron densities determined with the surface wave probe and a Langmuir probe, it was confirmed that the surface wave probe is highly available for diagnostic of the electron density in H{sup -} ion sources. In addition, it was found that the ratio of the electron density to the H{sup -} ion density dramatically decreases with increase of a bias voltage and the H{sup -} ions become dominant negative particles at the bias voltage of more than 6 V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial distribution of the charged particles and potentials during beam extraction in a negative-ion source

We report on the characteristics of the electronegative plasma in a large-scale hydrogen negative ion (H{sup -}) source. The measurement has been made with a time-resolved Langmuir probe installed in the beam extraction region. The H{sup -} density is monitored with a cavity ring-down system to identify the electrons in the negative charges. The electron-saturation current decreases rapidly after starting to seed Cs, and ion-ion plasma is observed in the extraction region. The H{sup -} density steps down during the beam extraction and the electron density jumps up correspondingly. The time integral of the decreasing H{sup -} charge density agrees well with the electron charge collected with the probe. The agreement of the charges is interpreted to indicate that the H{sup -} density decreasing at the beam extraction is compensated by the electrons diffusing from the driver region. In the plasmas with very low electron density, the pre-sheath of the extraction field penetrates deeply inside the plasmas. That is because the shielding length in those plasmas is longer than that in the usual electron-ion plasmas, and furthermore the electrons are suppressed to diffuse to the extraction region due to the strong magnetic field.

43 PARTICLE ACCELERATORS↗

Precision spectroscopy of kaonic {sup 3}He X-rays at J-PARC

We will measure the X-rays from kaonic {sup 3}He 3d {yields} 2p transition with a precision below 2 eV. It can provide crucial information on the kaon-nucleus strong interaction. The experiment (J-PARC E17) will be performed as Day-1, which is one of the first experiments in the J-PARC hadron facility in the year 2011. An overview and the present status of the J-PARC E17 experiment are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Spectroscopy of Kaonic Helium-3 X-rays at J-PARC

We will measure the x-rays from kaonic {sup 3}He and {sup 4}He 3d{yields}2p transition by using silicon drift detectors. Our precision goal is set to 1 eV to provide crucial information on the kaon-nucleus strong interaction in the low energy limit. The experiment is to be performed as one of the first experiment in the J-PARC hadron facility (J-PARC E17). An overview and the present status of the experiment are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Electron Density near Plasma Grid of Large-scaled Negative Ion Source by Means of Millimeter-Wave Interferometer

A millimeter-wave interferometer with the frequency of 39 GHz ({lambda} 7.7 mm) was newly installed to a large-scaled negative ion source. The measurable line-integrated electron density (n{sub e}l) is from 2x10{sup 16} to 7x10{sup 18} m{sup -2}, where n{sub e} and l represent an electron density and the plasma length along the millimeter-wave path, respectively. Our interest in this study is behavior of negative ions and reduction of electron density in the beam extraction region near the plasma grid. The first results show the possibility of the electron density measurement by the millimeter-wave interferometer in this region. The line-averaged electron density increases proportional to the arc power under the condition without cesium seeding. The significant decrease of the electron density and significant increase of the negative ion density were observed just after the cesium seeding. The electron density measured with the interferometer agrees well with that observed with a Langmuir probe. The very high negative ion ratio of n{sub H-}/(n{sub e}+n{sub H-}) = 0.85 was achieved within 400 min. after the cesium seeding.

43 PARTICLE ACCELERATORS↗

Stability of High Power Beam Injection in Negative-Ion-Based LHD-NBI

We describe the characteristic of stable beam injection in a neutral beam injector (NBI) for Large Helical Device (LHD) in high injection power of more than 6 MW. In the NBI, it takes a week after starting Cs seeding to finish the pre-injection conditioning. The injection starts with the beam power {approx}6.2 MW, and the maximum power reaches {approx}7 MW. The Cs-seeding rate affects the beam stability in such high power injections. By optimizing the rate to 0.65 mg/shot, the success ratio, which is defined as a ratio of actual pulse duration to setting one, increases to 85-90% in the power and energy range of more than 6.2 MW and 185 keV, respectively. The weights of Cs adsorbed on several surfaces in the ion sources of the NBI are measured by means of Inductively-Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), and averaged surface densities are calculated by dividing with the several surface areas. The seeded Cs of 99.5% is condensed in the plasma generator, and very tiny amount of Cs reaches the surfaces of the accelerator grids. This very low amount of Cs on the grids is interpreted that most of the Cs atom evaporated from the inner walls is ionized during the arc discharges, and repelled to the source plasmas by the electrostatic field for H- extraction.

43 PARTICLE ACCELERATORS↗

Effects of quartz particle size and water-to-solid ratio on hydrothermal synthesis of tobermorite studied by in-situ time-resolved X-ray diffraction

Hydrothermal synthesis process of tobermorite (5CaO.6SiO{sub 2}.5H{sub 2}O) has been investigated by in-situ X-ray diffraction using high-energy X-rays from a synchrotron radiation source in combination with a purpose-build autoclave cell. Dissolution rates of quartz were largely affected by its particle size distribution in the starting mixtures. However, the composition (Ca/Si) of non-crystalline C-S-H at the start of tobermorite formation was identical regardless of the quartz dissolution rate. An effect of water-to-solid ratio (w/s) was investigated for samples using fine particle quartz. Tobermorite did not occur with w/s of 1.7 but occurred with w/s higher than 3.0. Surprisingly, however, the dissolution curves of quartz were nearly identical for all samples with w/s from 1.7 to 9, indicating that the dissolution rate is predominated by surface area. Possible reaction mechanism for tobermorite formation will be discussed in terms of Ca and/or silicate ion concentration in the liquid phase and distribution of Ca/Si in non-crystalline C-S-H. - Graphical abstract: Time-resolved XRD data set was obtained at up to 190 deg. C under a saturated steam pressure. Tobermorite (5CaO.6SiO{sub 2}.5H{sub 2}O) formation reaction was investigated in detail for several different starting materials. Highlights: > Hydrothermal formation of tobermorite was monitored by in-situ XRD. > Ca/Si of C-S-H at the start time of tobermorite formation was determined. > The Ca/Si value was identical regardless of the quartz particle size in the starting mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRIGONOMETRIC PARALLAX OF W51 MAIN/SOUTH

We report measurement of the trigonometric parallax of W51 Main/South using the Very Long Baseline Array. We measure a value of 0.185 {+-} 0.010 mas corresponding to a distance of 5.41{sup +0.31}{sub -0.28} kpc. W51 Main/South is a well-known massive star-forming region near the tangent point of the Sagittarius spiral arm of the Milky Way. Our distance to W51 yields an estimate of the distance to the Galactic center of R{sub 0} = 8.3 {+-} 0.46 (statistical) {+-}1.0 (systematic) kpc by simple geometry. Combining the parallax and proper motion measurements for W51, we obtained the full-space motion of this massive star-forming region. We find W51 is in a nearly circular orbit about the Galactic center. The H{sub 2}O masers used for our parallax measurements trace four powerful bipolar outflows within a 0.4 pc size region, some of which are associated with dusty molecular hot cores and/or hyper- or ultra-compact H II regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Characteristics of 80 keV positive ion source for Large Helical Device

An additional beamline, BL5, equipped with four positive ion sources will be installed on Large Helical Device (LHD) in 2010. The performance of an ion source which generates 80 keV deuterium and 60 keV hydrogen beams was investigated. The structure of the ion source is based on that of a BL4 ion source on LHD. The main differences between the ion sources for the BL4 and BL5 are the acceleration voltages and the materials of plasma electrodes: copper and molybdenum, respectively. The molybdenum plasma electrode for BL5 has better performance than the copper plasma electrode of BL4. The integrated performance of the ion source for BL5 reached a value equivalent to {approx}58 A in the beam current of hydrogen positive ion at 60 keV in the beam energy.

43 PARTICLE ACCELERATORS↗

Beamlet characteristics in the accelerator with multislot grounded grid

Characteristics of multibeamlets are investigated by means of beamlet monitoring technique. The beamlets are extracted from an accelerator with multislot grounded grid and the profiles are observed as infrared images of temperature distributions on a cold isostatic pressed graphite plate exposed by H-beamlets. The optimal horizontal and vertical divergence angles of single beamlet are estimated at 4.1 and 6.1 mrad, respectively.

43 PARTICLE ACCELERATORS↗

TRIGONOMETRIC PARALLAXES OF MASSIVE STAR-FORMING REGIONS. VI. GALACTIC STRUCTURE, FUNDAMENTAL PARAMETERS, AND NONCIRCULAR MOTIONS

We are using the Very Long Baseline Array and the Japanese VLBI Exploration of Radio Astronomy project to measure trigonometric parallaxes and proper motions of masers found in high-mass star-forming regions across the Milky Way. Early results from 18 sources locate several spiral arms. The Perseus spiral arm has a pitch angle of 16 deg. {+-} 3 deg., which favors four rather than two spiral arms for the Galaxy. Combining positions, distances, proper motions, and radial velocities yields complete three-dimensional kinematic information. We find that star-forming regions on average are orbiting the Galaxy {approx}15 km s{sup -1} slower than expected for circular orbits. By fitting the measurements to a model of the Galaxy, we estimate the distance to the Galactic center R {sub 0} = 8.4 {+-} 0.6 kpc and a circular rotation speed {theta}{sub 0} = 254 {+-} 16 km s{sup -1}. The ratio {theta}{sub 0}/R {sub 0} can be determined to higher accuracy than either parameter individually, and we find it to be 30.3 {+-} 0.9 km s{sup -1} kpc{sup -1}, in good agreement with the angular rotation rate determined from the proper motion of Sgr A*. The data favor a rotation curve for the Galaxy that is nearly flat or slightly rising with Galactocentric distance. Kinematic distances are generally too large, sometimes by factors greater than 2; they can be brought into better agreement with the trigonometric parallaxes by increasing {theta}{sub 0}/R {sub 0} from the IAU recommended value of 25.9 km s{sup -1} kpc{sup -1} to a value near 30 km s{sup -1} kpc{sup -1}. We offer a 'revised' prescription for calculating kinematic distances and their uncertainties, as well as a new approach for defining Galactic coordinates. Finally, our estimates of {theta}{sub 0} and {theta}{sub 0}/R{sub 0}, when coupled with direct estimates of R {sub 0}, provide evidence that the rotation curve of the Milky Way is similar to that of the Andromeda galaxy, suggesting that the dark matter halos of these two dominant Local Group galaxy are comparably massive.

99 GENERAL AND MISCELLANEOUS↗

Multi-antenna RF Ion Source at a High RF Power Level

A multi-antenna radio-frequency ion source with a Faraday shield is newly tested at a high RF power level in a large area negative ion source of 1/5th scale of the Large Helical Device-NNBI ion source. Inductively coupled dense hydrogen plasmas were generated uniformly over an area of 25x25 cm{sup 2} at an RF input power up to 300 kW for a 10 ms pulse duration. A large negative plasma potential for the non-Faraday shielded antenna was remarkably reduced by introducing a Faraday shield. The positive ion saturation current density measured by Langmuir probe reached 148 mA/cm{sup 2} at 174 kW around the center of the plasma. The optimal hydrogen filling pressure ranged around 0.13 Pa- 0.4 Pa for the positive ions. Ion beam extraction with a single hole ({phi} 0.5 cm) extractor has been studied systematically. A maximum H{sup -} ion beam current density of 1.6 mA/cm{sup 2} was obtained preliminarily. It was confirmed that the plasma profile was controllable by both the number and configuration of the antennas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent Progress in the Negative-Ion-Based Neutral Beam Injectors in Large Helical Device

Negative-ion-based neutral beam injection (negative-NBI) system has been operated for 10 years in Large Helical Device (LHD). The injection power has been increased year by year, according to the improvement of the negative ion sources. Up to now, every injector achieves the designed injection energy and power of 180 keV-5 MW with hydrogen beams, and the total injection power exceeds 16 MW with three injectors. In the multi-round aperture grounded grid (GG), the diameter of a round aperture has been enlarged for higher GG transparency. Then, the GG heat load is reduced, as well as in the multi-slotted GG, and the voltage holding ability in the beam acceleration was improved. As a result, the beam energy is raised and the injection power is increased. To improve the anisotropic property of the beamlet convergence condition between the perpendicular and the parallel directions to the slots in the multi-slotted GG, a round-shape aperture of the steering grid (SG) has been changed to a racetrack shape. As a result, the difference of the beamlet conversion condition is much mitigated, and the injection efficiency (port-transmission efficiency) is improved, leading to 188 keV-6.4 MW injection. The Cs consumption is observed to be proportional to the tungsten evaporation from filaments. The Cs behavior is investigated with optical emission spectroscopy. During the beam extraction, the Cs recycling is dominated by Cs on the backplate, which is evaporated into the plasma by the backstreaming positive ions, and the wall surfaces should be loss regions for the supplied Cs.

43 PARTICLE ACCELERATORS↗