Characterization of a HPHT boron ion-implanted diamond X-ray mirror following high vacuum annealing
Not Available
Engineering topics
Publications and source records attributed to Sato, T..
Not Available
Not Available
Explore the source record for details and available documents.
We report the observation of photo-induced plasmon–phonon coupled modes in the group IV–VI semiconductor PbTe using ultrafast x-ray diffuse scattering at the Linac Coherent Light Source. We measure the near-zone-center excited-state dispersion of the heavily screened longitudinal optical (LO) phonon branch as extracted from differential changes in x-ray diffuse scattering intensity following above bandgap photoexcitation. We suggest that upon photoexcitation, the LO phonon-plasmon coupled (LOPC) modes themselves become coupled to longitudinal acoustic modes that drive electron band shifts via acoustic deformation potentials and possibly to low-energy single-particle excitations within the plasma and that these couplings give rise to displacement-correlations that oscillate in time with a period given effectively by the heavily screened LOPC frequency.
Not Available
Changing the flow rate of reactants being injected into a rotating detonation combustor (RDC) results in interesting behavior of the system. Prior studies have found that an increase in mass flow rate gradually increases the detonation wave speed before splitting the wave into multiple fronts. Here, the focus of this study is in understanding the physics of such behavior through a combination of experiments and numerical simulations. For this purpose, the axial air inlet-based RDC geometry is used. In the experiments, the wave velocity increased similar to prior studies. Corresponding full-scale simulations show that increase in mass flow rate by increasing pressure of the feed plenums shortens the recovery time of the injectors. This causes a more uniform fuel–air mixture to form prior to the arrival of the detonation wave. As a result, a more ideal detonation is observed, which leads to an increased wave velocity. Details of the detonation structure and variation with mass flow rate are analyzed. The presence and variation of the different deflagration zones in such non-premixed RDCs are also discussed.
The NuSTEC workshop held at the University of Pittsburgh in October 2019 brought theorists and experimentalists together to discuss the state of modeling and measurements related to pion production in neutrino-nucleus scattering in the kinematic region where pions are produced through both resonant and non-resonant mechanisms. Modeling of this region is of critical importance to the current and future accelerator- and atmospheric-based neutrino oscillation experiments. For the benefit of the community, links to the presentations are accompanied by annotations from the speakers highlighting significant points made during the presentations and resulting discussions.
In neutrino interactions with nucleons and nuclei, Shallow Inelastic Scattering (SIS) refers to processes, dominated by non-resonant contributions, in the kinematic region where $Q^2$ is small and the invariant mass of the hadronic system, $W$, is above the pion production threshold. The extremely rich science of this complex region, poorly understood both theoretically and experimentally, encompasses the transition from interactions described in terms of hadronic degrees of freedom to interactions with quarks and gluons described by perturbative QCD. Since a large fraction of events in NOvA and DUNE, and in atmospheric neutrino measurements such as IceCube-Upgrade, KM3NeT, Super- and Hyper-Kamiokande, are from this SIS region, there is a definite need to improve our knowledge of this physics. This LoI summarizes the current understandings of the SIS physics and a series of proposals for the path to forward.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Not Available
Not Available
Not Available
Here, this paper reports the first demonstration of high-intensity x-ray imaging using cadmium zinc telluride (CdZnTe) pixel detectors at a free electron laser (FEL). Prototype detectors were produced using the STFC large pixel detector (LPD) ASIC and sensors fabricated from a novel high-intensity-capable CdZnTe material produced by Redlen Technologies. Characterisation of the performance of this sensor material was completed at the Linac Coherent Light Source (LCLS) FEL. The detectors were operated at a frame rate of 1 MHz with 9.5 keV x-ray pulses delivered at a rate of 120 Hz. Measurements successfully demonstrated the linear response of the CdZnTe material to increasing numbers of x-rays up to a fluence of 8 GeV mm –2 per pulse, the limit of the dynamic range of the LPD ASIC.
Our understanding of radiation-induced cellular damage has greatly improved over the past few decades. Despite this progress, there are still many obstacles to fully understand how radiation interacts with biologically relevant cellular components, such as DNA, to cause observable end points such as cell killing. Damage in DNA is identified as a major route of cell killing. One hurdle when modeling biological effects is the difficulty in directly comparing results generated by members of different research groups. Multiple Monte Carlo codes have been developed to simulate damage induction at the DNA scale, while at the same time various groups have developed models that describe DNA repair processes with varying levels of detail. These repair models are intrinsically linked to the damage model employed in their development, making it difficult to disentangle systematic effects in either part of the modeling chain. These modeling chains typically consist of track-structure Monte Carlo simulations of the physical interactions creating direct damages to DNA, followed by simulations of the production and initial reactions of chemical species causing so-called “indirect” damages. After the induction of DNA damage, DNA repair models combine the simulated damage patterns with biological models to determine the biological consequences of the damage. To date, the effect of the environment, such as molecular oxygen (normoxic vs. hypoxic), has been poorly considered. We propose a new standard DNA damage (SDD) data format to unify the interface between the simulation of damage induction in DNA and the biological modeling of DNA repair processes, and introduce the effect of the environment (molecular oxygen or other compounds) as a flexible parameter. Such a standard greatly facilitates intermodel comparisons, providing an ideal environment to tease out model assumptions and identify persistent, underlying mechanisms. Through inter-model comparisons, this unified standard has the potential to significantly advance our understanding of the underlying mechanisms of radiation-induced DNA damage and the resulting observable biological effects when radiation parameters and/or environmental conditions change.
Recent studies confirmed that the materials used in the extreme UV and soft X-ray regime for precise characterization of intense free-electron laser pulses (e.g., Si 3 N 4 ) do not work efficiently in the hard X-ray regime, which is due to the fact that the impact of a hard X-ray photon is followed by a series of electron cascading processes. Following theoretical indication, we show that this limitation can be circumvented and the cascading time can be significantly reduced if the X-ray photon energy is double the ionization energy. We investigate an alternative material for pulse diagnostics, SnO 2 , using the Linac Coherent Light Source at photon energies of 5 keV and 9 keV. We prove the validity of the concept and show that it has a large potential for practical applications. In conclusion, by applying the proposed criteria, the temporal accuracy of the non-invasive pulse diagnostic tools can be improved in current and emerging hard X-ray facilities.