Search NASA⌕ Search

Engineering topics

Saunders, A.

Publications and source records attributed to Saunders, A..

At least 19 records

Demonstration of sub-micron UCN position resolution using room-temperature CMOS sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

10B nanometer thin film↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. In this work, the new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magnetogravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the HIBEAM/NNBAR experiment at the European Spallation Source

The violation of baryon number, , is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the Universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron–antineutron oscillation () via mixing, neutron–antineutron oscillation via regeneration from a sterile neutron state (), and neutron disappearance (n → n′); the effective process of neutron regeneration () is also possible. The program can be used to discover and characterize mixing in the neutron, antineutron and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis and the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental observations of exploding bridgewire detonator function

Exploding bridgewire detonators are an industry standard technology used for over 75 years and valued for their precise timing and safety characteristics. Despite widespread use, their functional mechanism remains controversial with both shock and non-shock mechanisms attributed. In this work, we re-examine bridgewire detonator function with a suite of modern diagnostics and compare these observations with the existing literature. Traditional detonator observations consisted of voltage applied to the bridgewire and time dependent current, integral response measurements such as case motion and more recently Schlieren imaging of the detonator surface. In this work, we add visible light emission, X-ray transmission, proton radiography, and temperature measurements during detonator function in addition to voltage, current, and function times. The addition of in-situ observations of light emission, temperature, and density gives us new insight into the mechanisms of explosive bridgewire detonator function. We see a distinct separation in time, location, symmetry, and velocity of bridgewire output and detonation onset. During the time between bridgewire burst and the initiation of detonation, we observe a temperature ramp in the input pellet. In this paper, we present the suite of measurements and comparisons with the literature on integral response measurements.

42 ENGINEERING↗

Dark field proton radiography

A pre- and post-collimation scheme has been applied to high energy proton radiography to establish a dark field condition, which defaults to a state of no transmission until a scatterer is placed at the object plane. This technique, dark field proton radiography, provides two additional capabilities to a standard proton radiography setup. First, protons with a high degree of angular dispersion are removed from the beam, reducing the effects of chromatic aberrations and decreasing noise. Second, protons below the same threshold are removed from the beam downstream of the objects, effectively making the transmission highly sensitive to small amounts of scatter at the object plane. Finally, initial results indicate that the system is highly sensitive to the presence of thinner materials and improves sensitivity to subtle areal density variations in thick objects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved limits on Fierz interference using asymmetry measurements from the Ultracold Neutron Asymmetry (UCNA) experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the β-decay asymmetry parameter, A 0 , for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their β-decay electrons are detected with ≈4π acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to b n , the Fierz interference term in the neutron β-decay rate. In this work, we determine bn from the energy dependence of A 0 using the data taken during the UCNA 2011–2013 run. In addition, we present the same type of analysis using the earlier 2010 A dataset. Furthermore, motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new b n measurement using the weighted average of our asymmetry dataset fits, to obtain b n = 0.066 ± 0.041 stat ± 0.024 syst which corresponds to a limit of -0.012 < b n < 0.144 at the 90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo simulations of trapped ultracold neutrons in the UCN τ experiment

We report that in the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trapping mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN—whose dynamics can be described by Hamiltonian mechanics—do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trapping in the UCNτ magnetogravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase-space evolution of neutrons observed in the UCNτ experiment. Lastly, we will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$\alpha$0$\gamma$)$^7$Li (6%) and $^{10}$B(n,$\alpha$1$\gamma$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $\alpha$, $^7$Li and $\gamma$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for the Neutron Decay n → X + γ , Where X is a Dark Matter Particle

Fornal and Grinstein recently proposed that the discrepancy between two different methods of neutron lifetime measurements, the beam and bottle methods, can be explained by a previously unobserved dark matter decay mode, n→X+γ. We perform a search for this decay mode over the allowed range of energies of the monoenergetic γ ray for X to be dark matter. A Compton-suppressed high-purity germanium detector is used to identify γ rays from neutron decay in a nickel-phosphorous-coated stainless-steel bottle. A combination of Monte Carlo and radioactive source calibrations is used to determine the absolute efficiency for detecting γ rays arising from the dark matter decay mode. Lastly, we exclude the possibility of a sufficiently strong branch to explain the lifetime discrepancy with 97% confidence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for dark matter decay of the free neutron from the UCNA experiment: n → χ + e + e –

It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle (χ) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single χ along with an e + e – pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with ~4π acceptance using a pair of detectors that observe a volume of stored ultracold neutrons. The summed kinetic energy (E e + e – ) from such events is used to set limits, as a function of the χ mass, on the branching fraction for this decay channel. For χ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at >>5σ level for 100 < E e + e – < 644keV. In conclusion, if the χ+e + e – final state is not the only one, we set limits on its branching fraction of <10 –4 for the above E e + e – range at >90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New result for the neutron β -asymmetry parameter A 0 from UCNA

Background: The neutron β-decay asymmetry parameter A 0 defines the angular correlation between the spin of the neutron and the momentum of the emitted electron. Values for A 0 permit an extraction of the ratio of the weak axial-vector to vector coupling constants, λ≡g A /g V , which under assumption of the conserved vector current hypothesis (g V =1) determines g A . Precise values for g A are important as a benchmark for lattice QCD calculations and as a test of the standard model. Purpose: The UCNA experiment, carried out at the Ultracold Neutron (UCN) source at the Los Alamos Neutron Science Center, was the first measurement of any neutron β-decay angular correlation performed with UCN. This article reports the most precise result for A 0 obtained to date from the UCNA experiment, as a result of higher statistics and reduced key systematic uncertainties, including from the neutron polarization and the characterization of the electron detector response. Methods: UCN produced via the downscattering of moderated spallation neutrons in a solid deuterium crystal were polarized via transport through a 7 T polarizing magnet and a spin flipper, which permitted selection of either spin state. The UCN were then contained within a 3-m long cylindrical decay volume, situated along the central axis of a superconducting 1 T solenoidal spectrometer. With the neutron spins then oriented parallel or anti-parallel to the solenoidal field, an asymmetry in the numbers of emitted decay electrons detected in two electron detector packages located on both ends of the spectrometer permitted an extraction of A 0 . Results: The UCNA experiment reports a new 0.67% precision result for A 0 of A 0 = -0.12054(44) stat (68) syst , which yields λ=g A /g V = -1.2783(22). Combination with the previous UCNA result and accounting for correlated systematic uncertainties produces A 0 = -0.12015(34) stat (63) syst and λ=g A /g V = -1.2772(20).Conclusions: This new result for A 0 and g A /g V from the UCNA experiment has provided confirmation of the shift in values for g A /g V that has emerged in the published results from more recent experiments, which are in striking disagreement with the results from older experiments. Individual systematic corrections to the asymmetries in older experiments (published prior to 2002) were >10%, whereas those in the more recent ones (published after 2002) have been of the scale of <2%. Finally, the impact of these older results on the global average will be minimized should future measurements of A 0 reach the 0.1% level of precision with central values near the most recent results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment

We report the ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the design and performance of the upgraded LANL UCN source. Measurements of the cold neutron spectrum and UCN density are presented and compared to Monte Carlo predictions. The source is shown to perform as modeled. The UCN density measured at the exit of the biological shield was 184(32) UCN / cm 3 , a fourfold increase from the highest previously reported. Finally, the polarized UCN density stored in an external chamber was measured to be 39(7) UCN / cm 3 , which is sufficient to perform an experiment to search for the nonzero neutron electric dipole moment with a one-standard-deviation sensitivity of σ(d n ) = 3 × 10 -27 e cm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First direct constraints on Fierz interference in free-neutron β decay

Precision measurements of free-neutron β decay have been used to precisely constrain our understanding of the weak interaction. However, the neutron Fierz interference term b n , which is particularly sensitive to beyond-standard-model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding b n =0.067±0.005 stat $+0.090\atop{-0.061}$ sys , consistent with the standard model. Lastly, the uncertainty is dominated by absolute energy reconstruction and the linearity of the β spectrometer energy response.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FY17 LLNL Omega Experimental Programs

The Capseed campaign goal is to measure shock front velocity non-uniformities in Inertial Confinement Fusion (ICF) ablator materials and quantify the level of non-uniformity caused by intrinsic effects. This is done using the Omega High Resolution Velocimeter (OHRV) to obtain velocity maps of the optically reflecting shock front following release of the ablator material into either PMMA for the warm experiments or cryogenic deuterium for the cryo experiments. For the three half-days in FY17 the focus was twofold: complete measurements on the impact of oxygen heterogeneity and oxygen mitigation layers for glow discharge polymer (GDP), and begin measuring velocity non-uniformities on deep release from Be, GDP, and highdensity carbon (HDC) into D2 with improved velocity sensitivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗