Search NASA⌕ Search

Engineering topics

Savukov, Igor

Publications and source records attributed to Savukov, Igor.

Sensitivity of ultralight axion dark matter search with optical quantum sensors

An optical quantum sensor (OQS) based on lasers and alkali-metal atoms is a sensitive ambient-temperature magnetometer that can be used in axion dark matter search with an inductor-capacitor (LC) circuit at kHz and MHz frequencies. We have previously investigated the sensitivity of an LC circuit-OQS axion detector to ultralight axion dark matter that could be achieved using a fT-noise OQS constructed in our lab. In this paper, we investigate the sensitivity that could be potentially reached by an OQS performing close to the fundamental quantum noise levels of 10 aT / $\sqrt{Hz}$. To take advantage of the quantum-limited OQS, the LC circuit has to be made of a superconductor and cooled to low temperature of a few K. After considering the intrinsic noise of the advanced axion detector and characterizing possible background noises, we estimate that such an experiment could probe benchmark QCD axion models in an unexplored mass range near 10 neV. Reaching such a high sensitivity is a difficult task, so we have conducted some preliminary experiments with a large-bore magnet and a prototype axion detector consisting of a room-temperature LC circuit and a commercial OQS unit. In conclusion, this paper describes the prototype experiment and its projected sensitivity to axions in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands

Here, we demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with 87 Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/ √ Hz with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth’s field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Broadband Ultra-Sensitive Adiabatic Magnetometer

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. In conclusion, we experimentally conducted alkali-metal density measurements, as an example of applications.

adiabatic magnetometer↗

Application of saturation absorption spectroscopy to study the hyperfine structure of 235U and accurate 235U/238U isotope ratio determinations at 861.031 nm

The uranium transition 5f 3 6d7s 2 ( 5 L 6 ) → 5f 3 7s 2 7p ( 5 K 5 ) at 861.031 nm was studied using saturation absorption spectroscopy. The hyperfine structure of the 235 U isotope was determined by measuring the Doppler-suppressed absorption spectrum, and the hyperfine structure constants were obtained by employing transition-specific line strength theory and spectral fitting. The magnetic-dipole and electric-quadrupole constants were determined to be A = -3.2887 ± 0.1957 mK and B = 31.8712 ± 8.0789 mK for the upper state 5f 3 7s 2 7p ( 5 K 5 ). A theoretical calculation for the hyperfine structure constants of the 235 U isotope was also carried out by the relativistic configuration-interaction (RCI) method, and the obtained values were found to be in agreement with the measured values. In addition, the line profile of 238 U was experimentally investigated for different excitation intensities and modeled using the RCI method for estimating the transition probability and oscillator strength, with various residual broadening mechanisms considered beyond the radiative decay. Finally, we show that these results allow us to make improvements on the precision of spectral measurements using our previously developed technique for isotope ratio determinations in atomic beams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗