Search NASA⌕ Search

Engineering topics

Sawant, A

Publications and source records attributed to Sawant, A.

At least 19 records

SU-D-207A-05: Investigating Sparse-Sampled MRI for Motion Management in Thoracic Radiotherapy

Purpose: Sparse sampling and reconstruction-based MRI techniques represent an attractive strategy to achieve sufficiently high image acquisition speed while maintaining image quality for the task of radiotherapy guidance. In this study, we examine rapid dynamic MRI using a sparse sampling sequence k-t BLAST in capturing motion-induced, cycle-to-cycle variations in tumor position. We investigate the utility of long-term MRI-based motion monitoring as a means of better characterizing respiration-induced tumor motion compared to a single-cycle 4DCT. Methods: An MRI-compatible, programmable, deformable lung motion phantom with eleven 1.5 ml water marker tubes was placed inside a 3.0 T whole-body MR scanner (Philips Ingenia). The phantom was programmed with 10 lung tumor motion traces previously recorded using the Synchrony system. 2D+t image sequences of a coronal slice were acquired using a balanced-SSFP sequence combined with k-t BLAST (accn=3, resolution=0.66×0.66×5 mm3; acquisition time = 110 ms/slice). kV fluoroscopic (ground truth) and 4DCT imaging was performed with the same phantom setup and motion trajectories. Marker positions in all three modalities were segmented and tracked using an opensource deformable image registration package, NiftyReg. Results: Marker trajectories obtained from rapid MRI exhibited <1 mm error compared to kv Fluoro trajectories in the presence of complex motion including baseline shifts and changes in respiratory amplitude, indicating the ability of MRI to monitor motion with adequate geometric fidelity for the purpose of radiotherapy guidance. In contrast, the trajectory derived from 4DCT exhibited significant errors up to 6 mm due to cycle-to-cycle variations and baseline shifts. Consequently, 4DCT was found to underestimate the range of marker motion by as much as 50%. Conclusion: Dynamic MRI is a promising tool for radiotherapy motion management as it permits for longterm, dose-free, soft-tissue-based monitoring of motion, yielding richer and more accurate information about tumor position and motion range compared to the current state-of-the-art, 4DCT. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

SU-F-T-256: 4D IMRT Planning Using An Early Prototype GPU-Enabled Eclipse Workstation

Purpose: True 4D IMRT planning, based on simultaneous spatiotemporal optimization has been shown to significantly improve plan quality in lung radiotherapy. However, the high computational complexity associated with such planning represents a significant barrier to widespread clinical deployment. We introduce an early prototype GPU-enabled Eclipse workstation for inverse planning. To our knowledge, this is the first GPUintegrated Eclipse system demonstrating the potential for clinical translation of GPU computing on a major commercially-available TPS. Methods: The prototype system comprised of four NVIDIA Tesla K80 GPUs, with a maximum processing capability of 8.5 Tflops per K80 card. The system architecture consisted of three key modules: (i) a GPU-based inverse planning module using a highly-parallelizable, swarm intelligence-based global optimization algorithm, (ii) a GPU-based open-source b-spline deformable image registration module, Elastix, and (iii) a CUDA-based data management module. For evaluation, aperture fluence weights in an IMRT plan were optimized over 9 beams,166 apertures and 10 respiratory phases (14940 variables) for a lung cancer case (GTV = 95 cc, right lower lobe, 15 mm cranio-caudal motion). Sensitivity of the planning time and memory expense to parameter variations was quantified. Results: GPU-based inverse planning was significantly accelerated compared to its CPU counterpart (36 vs 488 min, for 10 phases, 10 search agents and 10 iterations). The optimized IMRT plan significantly improved OAR sparing compared to the original internal target volume (ITV)-based clinical plan, while maintaining prescribed tumor coverage. The dose-sparing improvements were: Esophagus Dmax 50%, Heart Dmax 42% and Spinal cord Dmax 25%. Conclusion: Our early prototype system demonstrates that through massive parallelization, computationally intense tasks such as 4D treatment planning can be accomplished in clinically feasible timeframes. With further optimization, such systems are expected to enable the eventual clinical translation of higher-dimensional and complex treatment planning strategies to significantly improve plan quality. This work was partially supported through research funding from National Institutes of Health (R01CA169102) and Varian Medical Systems, Palo Alto, CA, USA.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-12: Head-To-Head Performance Characterization of Two Multileaf Collimator Tracking Algorithms for Radiotherapy

Purpose: Multi-leaf collimator (MLC) tracking is being clinically pioneered to continuously compensate for thoracic and abdominal motion during radiotherapy. The purpose of this work is to characterize the performance of two MLC tracking algorithms for cancer radiotherapy, based on a direct optimization and a piecewise leaf fitting approach respectively. Methods: To test the algorithms, both physical and in silico experiments were performed. Previously published high and low modulation VMAT plans for lung and prostate cancer cases were used along with eight patient-measured organ-specific trajectories. For both MLC tracking algorithm, the plans were run with their corresponding patient trajectories. The physical experiments were performed on a Trilogy Varian linac and a programmable phantom (HexaMotion platform). For each MLC tracking algorithm, plan and patient trajectory, the tracking accuracy was quantified as the difference in aperture area between ideal and fitted MLC. To compare algorithms, the average cumulative tracking error area for each experiment was calculated. The two-sample Kolmogorov-Smirnov (KS) test was used to evaluate the cumulative tracking errors between algorithms. Results: Comparison of tracking errors for the physical and in silico experiments showed minor differences between the two algorithms. The KS D-statistics for the physical experiments were below 0.05 denoting no significant differences between the two distributions pattern and the average error area (direct optimization/piecewise leaf-fitting) were comparable (66.64 cm2/65.65 cm2). For the in silico experiments, the KS D-statistics were below 0.05 and the average errors area were also equivalent (49.38 cm2/48.98 cm2). Conclusion: The comparison between the two leaf fittings algorithms demonstrated no significant differences in tracking errors, neither in a clinically realistic environment nor in silico. The similarities in the two independent algorithms give confidence in the use of either algorithm for clinical implementation.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-08: Swarm Intelligence-Based Personalized Respiratory Gating in Lung SAbR

Purpose: Respiratory gating is widely deployed as a clinical motion-management strategy in lung radiotherapy. In conventional gating, the beam is turned on during a pre-determined phase window; typically, around end-exhalation. In this work, we challenge the notion that end-exhalation is always the optimal gating phase. Specifically, we use a swarm-intelligence-based, inverse planning approach to determine the optimal respiratory phase and MU for each beam with respect to (i) the state of the anatomy at each phase and (ii) the time spent in that state, estimated from long-term monitoring of the patient’s breathing motion. Methods: In a retrospective study of five lung cancer patients, we compared the dosimetric performance of our proposed personalized gating (PG) with that of conventional end-of-exhale gating (CEG) and a previously-developed, fully 4D-optimized plan (combined with MLC tracking delivery). For each patient, respiratory phase probabilities (indicative of the time duration of the phase) were estimated over 2 minutes from lung tumor motion traces recorded previously using the Synchrony system (Accuray Inc.). Based on this information, inverse planning optimization was performed to calculate the optimal respiratory gating phase and MU for each beam. To ensure practical deliverability, each PG beam was constrained to deliver the assigned MU over a time duration comparable to that of CEG delivery. Results: Maximum OAR sparing for the five patients achieved by the PG and the 4D plans compared to CEG plans was: Esophagus Dmax [PG:57%, 4D:37%], Heart Dmax [PG:71%, 4D:87%], Spinal cord Dmax [PG:18%, 4D:68%] and Lung V13 [PG:16%, 4D:31%]. While patients spent the most time in exhalation, the PG-optimization chose end-exhale only for 28% of beams. Conclusion: Our novel gating strategy achieved significant dosimetric improvements over conventional gating, and approached the upper limit represented by fully 4D optimized planning while being significantly simpler and more clinically translatable. This work was partially supported through research funding from National Institutes of Health (R01CA169102) and Varian Medical Systems, Palo Alto, CA, USA.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-06: BEST IN PHYSICS (JOINT IMAGING-THERAPY): An MRI Compatible Externally and Internally Deformable Lung Motion Phantom for Multi-Modality IGRT

Purpose: MRI has become an attractive tool for tumor motion management. Current MR-compatible phantoms are only capable of reproducing translational motion. This study describes the construction and validation of a more realistic, MRI-compatible lung phantom that is deformable internally as well as externally. We demonstrate a radiotherapy application of this phantom by validating the geometric accuracy of the open-source deformable image registration software NiftyReg (UCL, UK). Methods: The outer shell of a commercially-available dynamic breathing torso phantom was filled with natural latex foam with eleven water tubes. A rigid foam cut-out served as the diaphragm. A high-precision programmable, in-house, MRI-compatible motion platform was used to drive the diaphragm. The phantom was imaged on a 3T scanner (Philips, Ingenia). Twenty seven tumor traces previously recorded from lung cancer patients were programmed into the phantom and 2D+t image sequences were acquired using a sparse-sampling sequence k-t BLAST (accn=3, resolution=0.66×0.66×5mm3; acquisition-time=110ms/slice). The geometric fidelity of the MRI-derived trajectories was validated against those obtained via fluoroscopy using the on board kV imager on a Truebeam linac. NiftyReg was used to perform frame by frame deformable image registration. The location of each marker predicted by using NiftyReg was compared with the values calculated by intensity-based segmentation on each frame. Results: In all cases, MR trajectories were within 1 mm of corresponding fluoroscopy trajectories. RMSE between centroid positions obtained from segmentation with those obtained by NiftyReg varies from 0.1 to 0.21 mm in the SI direction and 0.08 to 0.13 mm in the LR direction showing the high accuracy of deformable registration. Conclusion: We have successfully designed and demonstrated a phantom that can accurately reproduce deformable motion under a variety of imaging modalities including MRI, CT and x-ray fluodoscopy, making it an invaluable research tool for validating novel motion management strategies. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP1-01: Variable-Beam Fractionation for SAbR

Purpose: In current conventionally-fractionated as well as hypofractionated 3D conformal radiotherapy (CRT), the same beam arrangement is employed from fraction to fraction. We challenge this notion and postulate that by varying the beam arrangement between fractions we can achieve greater sparing of organs at risk (OARs) while maintaining PTV coverage. We use an inverse planning strategy using a swarm intelligence-based global optimization algorithm to exploit the additional degree of freedom represented by inter-fractional variation in beam angles. Methods: To evaluate our variable-beam fractionation (VBF) method, a 10-beam ITV-based conformal stereotactic ablative radiotherapy (CRT-SAbR) plan was optimized. In the clinical plan, 54 Gy was delivered to a 41cc lung tumor over 3 fractions. In VBF, each original clinically-assigned beam was multiplied to a bundle of n α-degree-spaced beams, n being number of fractions. Selection of α was a compromise between retaining similar tumor irradiation and separating inline OAR sub-regions. We optimized the beam fluence weights setting an upper limit for beam delivery duration (and implicitly, monitor units) along with clinical organ-based dose-volume constraints. Zero weights were allowed so that the optimization algorithm could remove unnecessary beams. All fractions in final plan had to deliver identical monitor units (MU) while satisfying a soft constraint on having no more than one beam from every n-beam bundle in each fraction. α was 10 degrees and the dose rate was 600 MU/min. Results: The VBF plan achieved significantly superior OAR sparing compared to the clinical internal target volume (ITV)-based plan. Setting maximum beam delivery duration to 13 seconds (well within breath-hold range), Esophagus Dmax, Heart Dmax, Spinal cord Dmax and Lung V13 were improved by 25%, 81%, 0% and 27%, respectively. Conclusion: We investigated a simple approach to inter-fractional VBF planning and demonstrated its potential in reducing dose to OARs. This work was partially supported through research funding from National Institutes of Health (R01CA169102) and Varian Medical Systems, Palo Alto, CA, USA.

60 APPLIED LIFE SCIENCES↗

TH-AB-202-08: A Robust Real-Time Surface Reconstruction Method On Point Clouds Captured From a 3D Surface Photogrammetry System

Purpose: Surface photogrammetry (e.g. VisionRT, C-Rad) provides a noninvasive way to obtain high-frequency measurement for patient motion monitoring in radiotherapy. This work aims to develop a real-time surface reconstruction method on the acquired point clouds, whose acquisitions are subject to noise and missing measurements. In contrast to existing surface reconstruction methods that are usually computationally expensive, the proposed method reconstructs continuous surfaces with comparable accuracy in real-time. Methods: The key idea in our method is to solve and propagate a sparse linear relationship from the point cloud (measurement) manifold to the surface (reconstruction) manifold, taking advantage of the similarity in local geometric topology in both manifolds. With consistent point cloud acquisition, we propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, building the point correspondences by the iterative closest point (ICP) method. To accommodate changing noise levels and/or presence of inconsistent occlusions, we further propose a modified sparse regression (MSR) model to account for the large and sparse error built by ICP, with a Laplacian prior. We evaluated our method on both clinical acquired point clouds under consistent conditions and simulated point clouds with inconsistent occlusions. The reconstruction accuracy was evaluated w.r.t. root-mean-squared-error, by comparing the reconstructed surfaces against those from the variational reconstruction method. Results: On clinical point clouds, both the SR and MSR models achieved sub-millimeter accuracy, with mean reconstruction time reduced from 82.23 seconds to 0.52 seconds and 0.94 seconds, respectively. On simulated point cloud with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent performance despite the introduced occlusions. Conclusion: We have developed a real-time and robust surface reconstruction method on point clouds acquired by photogrammetry systems. It serves an important enabling step for real-time motion tracking in radiotherapy. This work is supported in part by NIH grant R01 CA169102-02.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-07: Prediction of High Dimensional State Subject to Respiratory Motion: A Manifold Learning Approach

Purpose: The development of high dimensional imaging systems (e.g. volumetric MRI, CBCT, photogrammetry systems) in image-guided radiotherapy provides important pathways to the ultimate goal of real-time volumetric/surface motion monitoring. This study aims to develop a prediction method for the high dimensional state subject to respiratory motion. Compared to conventional linear dimension reduction based approaches, our method utilizes manifold learning to construct a descriptive feature submanifold, where more efficient and accurate prediction can be performed. Methods: We developed a prediction framework for high-dimensional state subject to respiratory motion. The proposed method performs dimension reduction in a nonlinear setting to permit more descriptive features compared to its linear counterparts (e.g., classic PCA). Specifically, a kernel PCA is used to construct a proper low-dimensional feature manifold, where low-dimensional prediction is performed. A fixed-point iterative pre-image estimation method is applied subsequently to recover the predicted value in the original state space. We evaluated and compared the proposed method with PCA-based method on 200 level-set surfaces reconstructed from surface point clouds captured by the VisionRT system. The prediction accuracy was evaluated with respect to root-mean-squared-error (RMSE) for both 200ms and 600ms lookahead lengths. Results: The proposed method outperformed PCA-based approach with statistically higher prediction accuracy. In one-dimensional feature subspace, our method achieved mean prediction accuracy of 0.86mm and 0.89mm for 200ms and 600ms lookahead lengths respectively, compared to 0.95mm and 1.04mm from PCA-based method. The paired t-tests further demonstrated the statistical significance of the superiority of our method, with p-values of 6.33e-3 and 5.78e-5, respectively. Conclusion: The proposed approach benefits from the descriptiveness of a nonlinear manifold and the prediction reliability in such low dimensional manifold. The fixed-point iterative approach turns out to work well practically for the pre-image recovery. Our approach is particularly suitable to facilitate managing respiratory motion in image-guide radiotherapy. This work is supported in part by NIH grant R01 CA169102-02.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-04: 4π Dynamic Conformal Arc Therapy Dynamic Conformal Arc Therapy (DCAT) for SBRT

Purpose: To develop an efficient and effective trajectory optimization methodology for 4π dynamic conformal arc treatment (4π DCAT) with synchronized gantry and couch motion; and to investigate potential clinical benefits for stereotactic body radiation therapy (SBRT) to breast, lung, liver and spine tumors. Methods: The entire optimization framework for 4π DCAT inverse planning consists of two parts: 1) integer programming algorithm and 2) particle swarm optimization (PSO) algorithm. The integer programming is designed to find an optimal solution for arc delivery trajectory with both couch and gantry rotation, while PSO minimize a non-convex objective function based on the selected trajectory and dose-volume constraints. In this study, control point interaction is explicitly taken into account. Beam trajectory was modeled as a series of control points connected together to form a deliverable path. With linear treatment planning objectives, a mixed-integer program (MIP) was formulated. Under mild assumptions, the MIP is tractable. Assigning monitor units to control points along the path can be integrated into the model and done by PSO. The developed 4π DCAT inverse planning strategy is evaluated on SBRT cases and compared to clinically treated plans. Results: The resultant dose distribution of this technique was evaluated between 3D conformal treatment plan generated by Pinnacle treatment planning system and 4π DCAT on a lung SBRT patient case. Both plans share the same scale of MU, 3038 and 2822 correspondingly to 3D conformal plan and 4π DCAT. The mean doses for most of OARs were greatly reduced at 32% (cord), 70% (esophagus), 2.8% (lung) and 42.4% (stomach). Conclusion: Initial results in this study show the proposed 4π DCAT treatment technique can achieve better OAR sparing and lower MUs, which indicates that the developed technique is promising for high dose SBRT to reduce the risk of secondary cancer.

60 APPLIED LIFE SCIENCES↗

SU-C-BRA-07: Virtual Bronchoscopy-Guided IMRT Planning for Mapping and Avoiding Radiation Injury to the Airway Tree in Lung SAbR

Purpose: Post-treatment radiation injury to central and peripheral airways is a potentially important, yet under-investigated determinant of toxicity in lung stereotactic ablative radiotherapy (SAbR). We integrate virtual bronchoscopy technology into the radiotherapy planning process to spatially map and quantify the radiosensitivity of bronchial segments, and propose novel IMRT planning that limits airway dose through non-isotropic intermediate- and low-dose spillage. Methods: Pre- and ∼8.5 months post-SAbR diagnostic-quality CT scans were retrospectively collected from six NSCLC patients (50–60Gy in 3–5 fractions). From each scan, ∼5 branching levels of the bronchial tree were segmented using LungPoint, a virtual bronchoscopic navigation system. The pre-SAbR CT and the segmented bronchial tree were imported into the Eclipse treatment planning system and deformably registered to the planning CT. The five-fraction equivalent dose from the clinically-delivered plan was calculated for each segment using the Universal Survival Curve model. The pre- and post-SAbR CTs were used to evaluate radiation-induced segmental collapse. Two of six patients exhibited significant segmental collapse with associated atelectasis and fibrosis, and were re-planned using IMRT. Results: Multivariate stepwise logistic regression over six patients (81 segments) showed that D0.01cc (minimum point dose within the 0.01cc receiving highest dose) was a significant independent factor associated with collapse (odds-ratio=1.17, p=0.010). The D0.01cc threshold for collapse was 57Gy, above which, collapse rate was 45%. In the two patients exhibiting segmental collapse, 22 out of 32 segments showed D0.01cc >57Gy. IMRT re-planning reduced D0.01cc below 57Gy in 15 of the 22 segments (68%) while simultaneously achieving the original clinical plan objectives for PTV coverage and OAR-sparing. Conclusion: Our results indicate that the administration of lung SAbR can Result in significant injury to bronchial segments, potentially impairing post-SAbR lung function. To our knowledge, this is the first investigation of functional avoidance based on mapping and minimizing dose to individual bronchial segments. The presenting author receives research funding from Varian Medical Systems, Elekta, and VisionRT.

60 APPLIED LIFE SCIENCES↗

SU-E-P-13: Quantifying the Geometric Error Due to Irregular Motion in Four-Dimensional Computed Tomography (4DCT)

Purpose: Respiratory correlated 4DCT images are generated under the assumption of a regular breathing cycle. This study evaluates the error in 4DCT-based target position estimation in the presence of irregular respiratory motion. Methods: A custom-made programmable externally-and internally-deformable lung motion phantom was placed inside the CT bore. An abdominal pressure belt was placed around the phantom to mimic clinical 4DCT acquisitio and the motion platform was programmed with a sinusoidal (±10mm, 10 cycles per minute) motion trace and 7 motion traces recorded from lung cancer patients. The same setup and motion trajectories were repeated in the linac room and kV fluoroscopic images were acquired using the on-board imager. Positions of 4 internal markers segmented from the 4DCT volumes were overlaid upon the motion trajectories derived from the fluoroscopic time series to calculate the difference between estimated (4DCT) and “actual” (kV fluoro) positions. Results: With a sinusoidal trace, absolute errors of the 4DCT estimated markers positions vary between 0.78mm and 5.4mm and RMS errors are between 0.38mm to 1.7mm. With irregular patient traces, absolute errors of the 4DCT estimated markers positions increased significantly by 100 to 200 percent, while the corresponding RMS error values have much smaller changes. Significant mismatches were frequently found at peak-inhale or peak-exhale phase. Conclusion: As expected, under conditions of well-behaved, periodic sinusoidal motion, the 4DCT yielded much better estimation of marker positions. When an actual patient trace is used 4DCT-derived positions showed significant mismatches with the fluoroscopic trajectories, indicating the potential for geometric and therefore dosimetric errors in the presence of cycle-to-cycle respiratory variations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-06: 4D Particle Swarm Optimization to Enable Lung SBRT in Patients with Central And/or Large Tumors

Purpose: Patients presenting with large and/or centrally-located lung tumors are currently considered ineligible for highly potent regimens such as SBRT due to concerns of toxicity to normal tissues and organs-at-risk (OARs). We present a particle swarm optimization (PSO)-based 4D planning technique, designed for MLC tracking delivery, that exploits the temporal dimension as an additional degree of freedom to significantly improve OAR-sparing and reduce toxicity to levels clinically considered as acceptable for SBRT administration. Methods: Two early-stage SBRT-ineligible NSCLC patients were considered, presenting with tumors of maximum dimensions of 7.4cm (central-right lobe; 1.5cm motion) and 11.9cm (upper-right lobe; 1cm motion). In each case, the target and normal structures were manually contoured on each of the ten 4DCT phases. Corresponding ten initial 3D-conformal plans (Pt#1: 7-beams; Pt#2: 9-beams) were generated using the Eclipse planning system. Using 4D-PSO, fluence weights were optimized over all beams and all phases (70 and 90 apertures for Pt1&2, respectively). Doses to normal tissues and OARs were compared with clinicallyestablished lung SBRT guidelines based on RTOG-0236. Results: The PSO-based 4D SBRT plan yielded tumor coverage and dose—sparing for parallel and serial OARs within the SBRT guidelines for both patients. The dose-sparing compared to the clinically-delivered conventionallyfractionated plan for Patient 1 (Patient 2) was: heart Dmean = 11% (33%); lung V20 = 16% (21%); lung Dmean = 7% (20%); spinal cord Dmax = 5% (16%); spinal cord Dmean = 7% (33%); esophagus Dmax = 0% (18%). Conclusion: Truly 4D planning can significantly reduce dose to normal tissues and OARs. Such sparing opens up the possibility of using highly potent and effective regimens such as lung SBRT for patients who were conventionally considered SBRT non-eligible. Given the large, non-convex solution space, PSO represents an attractive, parallelizable tool to successfully achieve a globally optimal solution for this problem. This work was supported through funding from the National Institutes of Health and Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-500: Initial Implementation of GPU-Based Particle Swarm Optimization for 4D IMRT Planning in Lung SBRT

Purpose 4D-IMRT planning, combined with dynamic MLC tracking delivery, utilizes the temporal dimension as an additional degree of freedom to achieve improved OAR-sparing. The computational complexity for such optimization increases exponentially with increase in dimensionality. In order to accomplish this task in a clinically-feasible time frame, we present an initial implementation of GPU-based 4D-IMRT planning based on particle swarm optimization (PSO). Methods The target and normal structures were manually contoured on ten phases of a 4DCT scan of a NSCLC patient with a 54cm3 right-lower-lobe tumor (1.5cm motion). Corresponding ten 3D-IMRT plans were created in the Eclipse treatment planning system (Ver-13.6). A vendor-provided scripting interface was used to export 3D-dose matrices corresponding to each control point (10 phases × 9 beams × 166 control points = 14,940), which served as input to PSO. The optimization task was to iteratively adjust the weights of each control point and scale the corresponding dose matrices. In order to handle the large amount of data in GPU memory, dose matrices were sparsified and placed in contiguous memory blocks with the 14,940 weight-variables. PSO was implemented on CPU (dual-Xeon, 3.1GHz) and GPU (dual-K20 Tesla, 2496 cores, 3.52Tflops, each) platforms. NiftyReg, an open-source deformable image registration package, was used to calculate the summed dose. Results The 4D-PSO plan yielded PTV coverage comparable to the clinical ITV-based plan and significantly higher OAR-sparing, as follows: lung Dmean=33%; lung V20=27%; spinal cord Dmax=26%; esophagus Dmax=42%; heart Dmax=0%; heart Dmean=47%. The GPU-PSO processing time for 14940 variables and 7 PSO-particles was 41% that of CPU-PSO (199 vs. 488 minutes). Conclusion Truly 4D-IMRT planning can yield significant OAR dose-sparing while preserving PTV coverage. The corresponding optimization problem is large-scale, non-convex and computationally rigorous. Our initial results indicate that GPU-based PSO with further software optimization can make such planning clinically feasible. This work was supported through funding from the National Institutes of Health and Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-03: Quantifying Patient Motion During Deep-Inspiration Breath-Hold Using the ABC System with Simultaneous Surface Photogrammetry

Purpose: Active breathing control (ABC) has been used to reduce treatment margin due to respiratory organ motion by enforcing temporary breath-holds. However, in practice, even if the ABC device indicates constant lung volume during breath-hold, the patient may still exhibit minor chest motion. Consequently, therapists are given a false sense of security that the patient is immobilized. This study aims at quantifying such motion during ABC breath-holds by monitoring the patient chest motion using a surface photogrammetry system, VisionRT. Methods: A female patient with breast cancer was selected to evaluate chest motion during ABC breath-holds. During the entire course of treatment, the patient’s chest surface was monitored by a surface photogrammetry system, VisionRT. Specifically, a user-defined region-of-interest (ROI) on the chest surface was selected for the system to track at a rate of ∼3Hz. The surface motion was estimated by rigid image registration between the current ROI image captured and a reference image. The translational and rotational displacements computed were saved in a log file. Results: A total of 20 fractions of radiation treatment were monitored by VisionRT. After removing noisy data, we obtained chest motion of 79 breath-hold sessions. Mean chest motion in AP direction during breath-holds is 1.31mm with 0.62mm standard deviation. Of the 79 sessions, the patient exhibited motion ranging from 0–1 mm (30 sessions), 1–2 mm (37 sessions), 2–3 mm (11 sessions) and >3 mm (1 session). Conclusion: Contrary to popular assumptions, the patient is not completely still during ABC breath-hold sessions. In this particular case studied, the patient exhibited chest motion over 2mm in 14 out of 79 breath-holds. Underestimating treatment margin for radiation therapy with ABC could reduce treatment effectiveness due to geometric miss or overdose of critical organs. The senior author receives research funding from NIH, VisionRT, Varian Medical Systems and Elekta.

60 APPLIED LIFE SCIENCES↗

WE-G-BRD-02: Characterizing Information Loss in a Sparse-Sampling-Based Dynamic MRI Sequence (k-T BLAST) for Lung Motion Monitoring

Purpose: Rapid MRI is an attractive, non-ionizing tool for soft-tissue-based monitoring of respiratory motion in thoracic and abdominal radiotherapy. One big challenge is to achieve high temporal resolution while maintaining adequate spatial resolution. K-t BLAST, sparse-sampling and reconstruction sequence based on a-priori information represents a potential solution. In this work, we investigated how much “true” motion information is lost as a-priori information is progressively added for faster imaging. Methods: Lung tumor motions in superior-inferior direction obtained from ten individuals were replayed into an in-house, MRI-compatible, programmable motion platform (50Hz refresh and 100microns precision). Six water-filled 1.5ml tubes were placed on it as fiducial markers. Dynamic marker motion within a coronal slice (FOV: 32×32cm{sup 2}, resolution: 0.67×0.67mm{sup 2}, slice-thickness: 5mm) was collected on 3.0T body scanner (Ingenia, Philips). Balanced-FFE (TE/TR: 1.3ms/2.5ms, flip-angle: 40degrees) was used in conjunction with k-t BLAST. Each motion was repeated four times as four k-t acceleration factors 1, 2, 5, and 16 (corresponding frame rates were 2.5, 4.7, 9.8, and 19.1Hz, respectively) were compared. For each image set, one average motion trajectory was computed from six marker displacements. Root mean square error (RMS) was used as a metric of spatial accuracy where measured trajectories were compared to original data. Results: Tumor motion was approximately 10mm. The mean(standard deviation) of respiratory rates over ten patients was 0.28(0.06)Hz. Cumulative distributions of tumor motion frequency spectra (0–25Hz) obtained from the patients showed that 90% of motion fell on 3.88Hz or less. Therefore, the frame rate must be a double or higher for accurate monitoring. The RMS errors over patients for k-t factors of 1, 2, 5, and 16 were.10(.04),.17(.04), .21(.06) and.26(.06)mm, respectively. Conclusions: K-t factor of 5 or higher can cover the high frequency component of tumor respiratory motion, while the estimated error of spatial accuracy was approximately.2mm.

60 APPLIED LIFE SCIENCES↗

TH-A-9A-02: BEST IN PHYSICS (THERAPY) - 4D IMRT Planning Using Highly- Parallelizable Particle Swarm Optimization

Purpose: We present a particle swarm optimization (PSO)-based 4D IMRT planning technique designed for dynamic MLC tracking delivery to lung tumors. The key idea is to utilize the temporal dimension as an additional degree of freedom rather than a constraint in order to achieve improved sparing of organs at risk (OARs). Methods: The target and normal structures were manually contoured on each of the ten phases of a 4DCT scan acquired from a lung SBRT patient who exhibited 1.5cm tumor motion despite the use of abdominal compression. Corresponding ten IMRT plans were generated using the Eclipse treatment planning system. These plans served as initial guess solutions for the PSO algorithm. Fluence weights were optimized over the entire solution space i.e., 10 phases × 12 beams × 166 control points. The size of the solution space motivated our choice of PSO, which is a highly parallelizable stochastic global optimization technique that is well-suited for such large problems. A summed fluence map was created using an in-house B-spline deformable image registration. Each plan was compared with a corresponding, internal target volume (ITV)-based IMRT plan. Results: The PSO 4D IMRT plan yielded comparable PTV coverage and significantly higher dose—sparing for parallel and serial OARs compared to the ITV-based plan. The dose-sparing achieved via PSO-4DIMRT was: lung Dmean = 28%; lung V20 = 90%; spinal cord Dmax = 23%; esophagus Dmax = 31%; heart Dmax = 51%; heart Dmean = 64%. Conclusion: Truly 4D IMRT that uses the temporal dimension as an additional degree of freedom can achieve significant dose sparing of serial and parallel OARs. Given the large solution space, PSO represents an attractive, parallelizable tool to achieve globally optimal solutions for such problems. This work was supported through funding from the National Institutes of Health and Varian Medical Systems. Amit Sawant has research funding from Varian Medical Systems, VisionRT Ltd. and Elekta.

60 APPLIED LIFE SCIENCES↗

SU-C-BRF-05: Design and Geometric Validation of An Externally and Internally Deformable, Programmable Lung Motion Phantom

Purpose: Most clinically-deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating, tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are rigid-exterior+rigid-interior or rigid-exterior+deformable-interior. Neither class adequately represents the human anatomy, which is deformable internally as well as externally. We describe the construction and experimental validation of a more realistic, externally- and internally-deformable, programmable lung phantom. Methods: The outer shell of a commercially-available lung phantom (RS- 1500, RSD Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A 3-axis platform was programmed with sinusoidal and six patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam ‘diaphragm’ that compressed/decompressed the phantom interior. Experimental characterization comprised of mapping the superior-inferior (SI) and anterior-posterior (AP) trajectories of external and internal radioopaque markers with kV x-ray fluoroscopy and correlating these with optical surface monitoring using the in-room VisionRT system. Results: The phantom correctly reproduced the programmed motion as well as realistic effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.4 mm RMS error for internal as well as external markers. The motion trajectories of internal and external markers as measured by fluoroscopy were found to be highly correlated (R=0.97). Furthermore, motion trajectories of arbitrary points on the deforming phantom surface, as recorded by the VisionRT system also showed a high correlation with respect to the fluoroscopically-measured trajectories of internal markers (R=0.92). Conclusion: We have developed a realistic externally- and internally-deformable lung phantom that will serve as a valuable tool for clinical QA and motion management research. This work was supported through funding from the NIH and VisionRT Ltd. Amit Sawant has research funding from Varian Medical Systems, VisionRT and Elekta.

60 APPLIED LIFE SCIENCES↗

SU-E-J-170: Beyond Single-Cycle 4DCT: Maximum a Posteriori (MAP) Reconstruction-Based Binning-Free Multicycle 4DCT for Lung Radiotherapy

Purpose: Thoracic motion changes from cycle-to-cycle and day-to-day. Conventional 4DCT does not capture these cycle to cycle variations. We present initial results of a novel 4DCT reconstruction technique based on maximum a posteriori (MAP) reconstruction. The technique uses the same acquisition process (and therefore dose) as a conventional 4DCT in order to create a high spatiotemporal resolution cine CT that captures several breathing cycles. Methods: Raw 4DCT data were acquired from a lung cancer patient. The continuous 4DCT was reconstructed using MAP algorithm which uses the raw, time-stamped CT data to reconstruct images while simultaneously estimating deformation in the subject's anatomy. This framework incorporates physical effects such as hysteresis and is robust to detector noise and irregular breathing patterns. The 4D image is described in terms of a 3D reference image defined at one end of the hysteresis loop, and two deformation vector fields (DVFs) corresponding to inhale motion and exhale motion respectively. The MAP method uses all of the CT projection data and maximizes the log posterior in order to iteratively estimate a timevariant deformation vector field that describes the entire moving and deforming volume. Results: The MAP 4DCT yielded CT-quality images for multiple cycles corresponding to the entire duration of CT acquisition, unlike the conventional 4DCT, which only yielded a single cycle. Variations such as amplitude and frequency changes and baseline shifts were clearly captured by the MAP 4DC Conclusion: We have developed a novel, binning-free, parameterized 4DCT reconstruction technique that can capture cycle-to-cycle variations of respiratory motion. This technique provides an invaluable tool for respiratory motion management research. This work was supported by funding from the National Institutes of Health and VisionRT Ltd. Amit Sawant receives research funding from Varian Medical Systems, Vision RT and Elekta.

60 APPLIED LIFE SCIENCES↗