Search NASA⌕ Search

Engineering topics

Scartezzini, Jean-Louis

Publications and source records attributed to Scartezzini, Jean-Louis.

Quantifying the impacts of climate change and extreme climate events on energy systems

Climate induced extreme weather events and weather variations will affect both the demand of energy and the resilience of energy supply systems. The specific potential impact of extreme events on energy systems has been difficult to quantify due to the unpredictability of future weather events. In this work, we develop a stochastic-robust optimization method to consider both low impact variations and extreme events. Applications of the method to 30 cities in Sweden, by considering 13 climate change scenarios, reveal that uncertainties in renewable energy potential and demand can lead to a significant performance gap (up to 34% for grid integration) brought by future climate variations and a drop in power supply reliability (up to 16%) due to extreme weather events. Finally, appropriate quantification of the climate change impacts will ensure robust operation of the energy systems and enable renewable energy penetration above 30% for a majority of the cities.

54 ENVIRONMENTAL SCIENCES↗

Split-pane electrochromic window control based on an embedded photometric device with real-time daylighting computing

Well-designed electrochromic (EC) glazing control can improve the energy performance of buildings and visual comfort of occupants in highly glazed buildings. Here in this paper, we designed and demonstrated a compact integrated EC glazing automation system to control tint states of a split-pane EC window according to variations of sky conditions. The control is based on monitoring the luminance distribution of the sky and real-time lighting computation for a building interior, using an embedded photometric device (EPD). It optimizes tint states of EC glazing to offer sufficient daylight provision and temper discomfort glare for occupants, which potentially mitigates excessive solar heat gain. ’In-situ’ experiments were conducted in a full-scale testbed to demonstrate the daylighting performance under various sky conditions. Finally, experimental results showed 83% of the working time for work-plane illuminance (WPI) and 95% of the time for daylight glare probability (DGP) were constrained in comfort range (WPIϵ[500, 2000] lux, DGP ≤ 0.35) by the automated EC glazing (controlled by EPD) under clear skies; 68% of the time for WPI and 94% of the time for DGP in confined range under clear skies with thin clouds; 62% of the time for WPI and 85% of the time for DGP in confined range under partly cloudy skies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of Anidolic Daylighting Systems in tropical climates - Parametric studies for identification of main influencing factors

Making daylight more available in buildings is highly desirable, not only for reasons of energy-efficiency, but also for improvement of occupants' health and well-being. Core-daylighting, that is daylight provision in areas situated at considerable distances from facades and windows, is currently one of the main challenges in sustainable building design. Anidolic Daylighting Systems (ADSs) are one very promising technology in the field of core-daylighting, but commercial solutions that are not only well-performing but also financially competitive are not yet widely available. This article presents results of parametric studies on Anidolic Integrated Ceilings (AICs), a special type of ADS, for identification of main influencing factors. The article describes a reliable method for simulating ADS and AIC performance under given sky conditions. Various simulation results for the example location Singapore are discussed in detail, it is concluded that the main influencing factors are coating material, system dimensions and external obstruction, and those influencing factors' potential impacts are quantified. It is shown that AIC overall efficiencies can reach up to almost 50% in Singapore. The essentially new results presented in this article can be of great help to architects, engineers and scientists in the future, when it comes to precisely dimensioning ADS for various buildings and daylight conditions. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ray tracing study for non-imaging daylight collectors

This paper presents a novel method to study how well non-imaging daylight collectors pipe diffuse daylight into long horizontal funnels for illuminating deep buildings. Forward ray tracing is used to derive luminous intensity distributions curves (LIDC) of such collectors centered in an arc-shaped light source representing daylight. New photometric characteristics such as 2D flux, angular spread and horizontal offset are introduced as a function of such LIDC. They are applied for quantifying and thus comparing different collector contours. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing lighting power density in office rooms equipped with Anidolic Daylighting Systems

Electric lighting is responsible for up to one third of an office building's electricity needs. Making daylight more available in office buildings can not only contribute to significant energy savings but also enhance the occupants' performance and wellbeing. Anidolic Daylighting Systems (ADS) are one type of very effective facade-integrated daylighting systems. All south-facing office rooms within the LESO solar experimental building in Lausanne (Switzerland) are equipped with a given type of ADS. A recent study has shown that these offices' occupants are highly satisfied with their lighting environment. The most energy-efficient south-facing offices have a lighting power density of less than 5W/m{sup 2}. The lighting situation within these ''best practice''-offices has been assessed using the lighting simulation software RELUX Vision. Because this lighting situation is very much appreciated by the occupants, it was used as a starting point for developing even more energy-efficient office lighting designs. Two new lighting designs, leading to lighting power densities of 3.9W/m{sup 2} and 3W/m{sup 2}, respectively, have been suggested and simulated with RELUX Vision. Simulation results have shown that the expected performances of these new systems are comparable to that of the current lighting installation within the ''best practice''-offices or even better. These simulation results have been confirmed during experiments on 20 human subjects in a test office room recently set up within the LESO building. This article gives engineers, architects and light planers valuable information and ideas on how to design energy-efficient and comfortable electric lighting systems in office rooms with abundant access to daylight. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modelling Complex Fenestration Systems using physical and virtual models

Physical or virtual models are commonly used to visualize the conceptual ideas of architects, lighting designers and researchers; they are also employed to assess the daylighting performance of buildings, particularly in cases where Complex Fenestration Systems (CFS) are considered. Recent studies have however revealed a general tendency of physical models to over-estimate this performance, compared to those of real buildings; these discrepancies can be attributed to several reasons. In order to identify the main error sources, a series of comparisons in-between a real building (a single office room within a test module) and the corresponding physical and virtual models was undertaken. The physical model was placed in outdoor conditions, which were strictly identical to those of the real building, as well as underneath a scanning sky simulator. The virtual model simulations were carried out by way of the Radiance program using the GenSky function; an alternative evaluation method, named Partial Daylight Factor method (PDF method), was also employed with the physical model together with sky luminance distributions acquired by a digital sky scanner during the monitoring of the real building. The overall daylighting performance of physical and virtual models were assessed and compared. The causes of discrepancies between the daylighting performance of the real building and the models were analysed. The main identified sources of errors are the reproduction of building details, the CFS modelling and the mocking-up of the geometrical and photometrical properties. To study the impact of these errors on daylighting performance assessment, computer simulation models created using the Radiance program were also used to carry out a sensitivity analysis of modelling errors. The study of the models showed that large discrepancies can occur in daylighting performance assessment. In case of improper mocking-up of the glazing for instance, relative divergences of 25-40% can be found in different room locations, suggesting that more light is entering than actually monitored in the real building. All these discrepancies can however be reduced by making an effort to carefully mock up the geometry and photometry of the real building. A synthesis is presented in this article which can be used as guidelines for daylighting designers to avoid or estimate errors during CFS daylighting performance assessment. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗