Search NASA⌕ Search

Engineering topics

Scerbo, Mark W.

Publications and source records attributed to Scerbo, Mark W..

Uterine Contraction Modeling and Simulation

Building a training system for medical personnel to properly interpret fetal heart rate tracing requires developing accurate models that can relate various signal patterns to certain pathologies. In addition to modeling the fetal heart rate signal itself, the change of uterine pressure that bears strong relation to fetal heart rate and provides indications of maternal and fetal status should also be considered. In this work, we have developed a group of parametric models to simulate uterine contractions during labor and delivery. Through analysis of real patient records, we propose to model uterine contraction signals by three major components: regular contractions, impulsive noise caused by fetal movements, and low amplitude noise invoked by maternal breathing and measuring apparatus. The regular contractions are modeled by an asymmetric generalized Gaussian function and least squares estimation is used to compute the parameter values of the asymmetric generalized Gaussian function based on uterine contractions of real patients. Regular contractions are detected based on thresholding and derivative analysis of uterine contractions. Impulsive noise caused by fetal movements and low amplitude noise by maternal breathing and measuring apparatus are modeled by rational polynomial functions and Perlin noise, respectively. Experiment results show the synthesized uterine contractions can mimic the real uterine contractions realistically, demonstrating the effectiveness of the proposed algorithm.

Liu, Miao↗

A Comparison of a Brain-Based Adaptive System and a Manual Adaptable System for Invoking Automation

Two experiments are presented that examine alternative methods for invoking automation. In each experiment, participants were asked to perform simultaneously a monitoring task and a resource management task as well as a tracking task that changed between automatic and manual modes. The monitoring task required participants to detect failures of an automated system to correct aberrant conditions under either high or low system reliability. Performance on each task was assessed as well as situation awareness and subjective workload. In the first experiment, half of the participants worked with a brain-based system that used their EEG signals to switch the tracking task between automatic and manual modes. The remaining participants were yoked to participants from the adaptive condition and received the same schedule of mode switches, but their EEG had no effect on the automation. Within each group, half of the participants were assigned to either the low or high reliability monitoring task. In addition, within each combination of automation invocation and system reliability, participants were separated into high and low complacency potential groups. The results revealed no significant effects of automation invocation on the performance measures; however, the high complacency individuals demonstrated better situation awareness when working with the adaptive automation system. The second experiment was the same as the first with one important exception. Automation was invoked manually. Thus, half of the participants pressed a button to invoke automation for 10 s. The remaining participants were yoked to participants from the adaptable condition and received the same schedule of mode switches, but they had no control over the automation. The results showed that participants who could invoke automation performed more poorly on the resource management task and reported higher levels of subjective workload. Further, those who invoked automation more frequently performed more poorly on the tracking task and reported higher levels of subjective workload. and the adaptable condition in the second experiment revealed only one significant difference: the subjective workload was higher in the adaptable condition. Overall, the results show that a brain-based, adaptive automation system may facilitate situation awareness for those individuals who are more complacent toward automation. By contrast, requiring operators to invoke automation manually may have some detrimental impact on performance but does appear to increases subjective workload relative to an adaptive system.

Bailey, Nathan R.↗

Effects of a psychophysiological system for adaptive automation on performance, workload, and the event-related potential P300 component

The present study examined the effects of an electroencephalographic- (EEG-) based system for adaptive automation on tracking performance and workload. In addition, event-related potentials (ERPs) to a secondary task were derived to determine whether they would provide an additional degree of workload specificity. Participants were run in an adaptive automation condition, in which the system switched between manual and automatic task modes based on the value of each individual's own EEG engagement index; a yoked control condition; or another control group, in which task mode switches followed a random pattern. Adaptive automation improved performance and resulted in lower levels of workload. Further, the P300 component of the ERP paralleled the sensitivity to task demands of the performance and subjective measures across conditions. These results indicate that it is possible to improve performance with a psychophysiological adaptive automation system and that ERPs may provide an alternative means for distinguishing among levels of cognitive task demand in such systems. Actual or potential applications of this research include improved methods for assessing operator workload and performance.

Task Performance and Analysis↗

Three Experiments Examining the Use of Electroencephalogram,Event-Related Potentials, and Heart-Rate Variability for Real-Time Human-Centered Adaptive Automation Design

Adaptive automation represents an advanced form of human-centered automation design. The approach to automation provides for real-time and model-based assessments of human-automation interaction, determines whether the human has entered into a hazardous state of awareness and then modulates the task environment to keep the operator in-the-loop , while maintaining an optimal state of task engagement and mental alertness. Because adaptive automation has not matured, numerous challenges remain, including what the criteria are, for determining when adaptive aiding and adaptive function allocation should take place. Human factors experts in the area have suggested a number of measures including the use of psychophysiology. This NASA Technical Paper reports on three experiments that examined the psychophysiological measures of event-related potentials, electroencephalogram, and heart-rate variability for real-time adaptive automation. The results of the experiments confirm the efficacy of these measures for use in both a developmental and operational role for adaptive automation design. The implications of these results and future directions for psychophysiology and human-centered automation design are discussed.

Prinzel, Lawrence J., III↗

Empirical Analysis of EEG and ERPs for Psychophysiological Adaptive Task Allocation

The present study was designed to test the efficacy of using Electroencephalogram (EEG) and Event-Related Potentials (ERPs) for making task allocation decisions. Thirty-six participants were randomly assigned to an experimental, yoked, or control group condition. Under the experimental condition, a tracking task was switched between task modes based upon the participant's EEG. The results showed that the use of adaptive aiding improved performance and lowered subjective workload under negative feedback as predicted. Additionally, participants in the adaptive group had significantly lower RMSE and NASA-TLX ratings than participants in either the yoked or control group conditions. Furthermore, the amplitudes of the N1 and P3 ERP components were significantly larger under the experimental group condition than under either the yoked or control group conditions. These results are discussed in terms of the implications for adaptive automation design.

Prinzel, Lawrence J., III↗

The Efficacy of Psychophysiological Measures for Implementing Adaptive Technology

Adaptive automation refers to technology that can change its mode of operation dynamically. Further, both the technology and the operator can initiate changes in the level or mode of automation. The present paper reviews research on adaptive technology. It is divided into three primary sections. In the first section, issues surrounding the development and implementation of adaptive automation are presented. Because physiological-based measures show much promise for implementing adaptive automation, the second section is devoted to examining candidate indices. In the final section, those techniques that show the greatest promise for adaptive automation as well as issues that still need to be resolved are discussed.

Scerbo, Mark W.↗

External Validity Considerations of a Biocybernetic System for Adaptive Automation

The report discusses the results of a research project aimed at generating a software application library termed the DAQ EEG Processor (or DEP) that collects and processes raw electroencephalographic data. The purpose of this system is to reduce raw EEG data in real time into information that is useful to researchers, such as power bands and indices of engagement. DEP improves upon existing EEG processing systems in that it can be seamlessly integrated into many software development environments to provide realtime data. DEP takes advantage of Microsoft Corporation's Component Object Model Technology (COM), which, in short, allows language independent, inter-application communication and transfer of data. According to the COM specification, COM objects can be written in different languages, run in different process spaces and on different platforms. As long as the objects adhere to the specification, they can communicate.

Scerbo, Mark W.↗

User Acceptability of Physiological and Other Measures of Hazardous States of Awareness

Two studies explored user acceptance of devices that measure hazardous states of awareness. In the first study, critical incident data were collected in two workshops from 11 operators working as air traffic controllers or commercial pilots. These critical incident data were used to develop a survey of the acceptability of awareness measures. In the second study, the survey was administered to 100 people also working as air traffic controllers or commercial pilots. Results show that operators are open to the inclusion of technology to measure HSAs even if that technology is somewhat invasive as long as feedback about the HSAs is considered to be useful and helpful. Nonetheless, a major concern is the legal complications associated with being recorded, particularly for older and more experienced operators. Air traffic controllers emphasized the importance of sharing technology information with supervisors in order to receive backup or assistance under conditions of task overload, whereas pilots emphasized the influence of work schedules on problems with awareness. Recommendations are offered concerning the implementation of devices to measure hazardous states of awareness.

Dickinson, Terry L.↗