Search NASASearch

Engineering topics

Schaefer, R. F.

Publications and source records attributed to Schaefer, R. F..

Determination of life for a polyimide-epoxy alternator insulation system

Tests were conducted to predict remaining electrical insulation life of a polyimide epoxy insulated 60 KW, 208 volt homopolar inductor alternator, following completion of 23,130 hours of turbo-alternator endurance tests. The sectioned armature winding of this alternator stator was used as means to evaluate and measure end-life at several aging temperatures for development of an Arrhenius plot. A one-half life rate of 11.3 C was established from these data with a predicted remaining life of 60,000 hours at an armature winding temperature of 248 C and a total life, including endurance test time, of 61,645 hours.

Penn, W. B.

Alternator insulation evaluation tests

Tests were conducted to predict the remaining electrical insulation life of a 60 KW homopolar inductor alternator following completion of NASA turbo-alternator endurance tests for SNAP-8 space electrical power systems application. The insulation quality was established for two alternators following completion of these tests. A step-temperature aging test procedure was developed for insulation life prediction and applied to one of the two alternators. Armature winding insulation life of over 80,000 hours for an average winding temperature of 248 degrees C was predicted using the developed procedure.

Penn, W. B.