Search NASA⌕ Search

Engineering topics

Scharrer, J. K.

Publications and source records attributed to Scharrer, J. K..

Preliminary experimental results for a cryogenic brush seal configuration

Preliminary fluid nitrogen flow data are reported for a five-brush, ceramic-coated-rub-runner brush seal system, where the brushes and the rub runner were placed at each end of a centrally pressurized multifunction tester ('back-to-back' set of brushes) and tested at rotor speeds of 0, 10, 18, and 22.5 krpm. After testing, both the brushes and the ceramic-coated rub runner appeared pristine. The coating withstood both the thermomechanical and dynamic loadings with minor wear track scarring. The bristle tips showed some indication of material shearing (smearing) wear. The Ergun porous flow equation was applied to the brush seal data. The Ergun relation, which required heuristic information to characterize the coefficients, fit the gaseous data but was in poor agreement with the fluid results. The brush seal exit conditions were two phase. Two-phase, choked-flow design charts were applied but required one data point at each rotor speed to define the (C(sub f)A x Constant) flow and area coefficients. Reasonable agreement between prediction and data was found, as expected, but such methods are not to be construed as two-phase-flow brush seal analyses.

Carlile, J. A.↗

Preliminary experimental results for a cryogenic brush seal configuration

Preliminary fluid nitrogen flow data are reported for a five-brush, ceramic-coated-rub-runner brush seal system, where the brushes and the rub runner were placed at each end of a centrally pressurized multifunction tester ('back-to-back' set of brushes) and tested at rotor speeds of 0, 10, 18, and 22.5 krpm. After testing, both the brushes and the ceramic-coated rub runner appeared pristine. The coating withstood both the thermomechanical and dynamic loadings with minor wear track scarring. The bristle tips showed some indication of material shearing (smearing) wear. The Ergun (1952) porous flow equation was applied to the brush seal data. The Ergun relation fit the gaseous data but was in poor agreement with the fluid results. The brush seal exit conditions were two phase. Two-phase, choked-flow design charts were applied but required one data point at each rotor speed to define the flow and area coefficients. Reasonable agreement between prediction and data was found, but such methods are not to be construed as two-phase-flow brush seal analyses.

Carlile, J. A.↗

Theory versus experiment for the rotordynamic coefficients of labyrinth gas seals. I - A two control volume model

The basic equations are derived for a two-control-volume model for compressible flow in a labyrinth seal. The recirculation velocity in the cavity is incorporated into the model for the first time. The flow is assumed to be completely turbulent and isoenergetic. The wall friction factors are determined using the Blasius formula. Jet flow theory is used for the calculation of the recirculation velocity in the cavity. Linearized zeroth- and first-order perturbation equations are developed for small motion about a centered position by an expansion in the eccentricity ratio. The zeroth-order pressure distribution is found by satisfying the leakage equation while the circumferential velocity distribution is determined by satisfying the momentum equations. The first-order equations are solved by a separation of variable solution. Integration of the resultant pressure distribution along and around the seal defines the reaction force developed by the seal and the corresponding dynamic coefficients.

Scharrer, J. K.↗

Theory versus experiment for the rotordynamic coefficients of labyrinth gas seals. II - A comparison to experiment

An experimental test facility is used to measure the leakage and rotordynamic coefficients of teeth-on-rotor and teeth-on-stator labyrinth gas seals. The test results are presented along with the theoretically predicted values for the two seal configurations at three different radial clearances and shaft speeds to 16,000 cpm. The test results show that the theory accurately predicts the cross-coupled stiffness for both seal configurations and shows improvement in the prediction of the direct damping for the teeth-on-rotor seal. The theory fails to predict a decrease in the direct damping coefficient for an increase in the radial clearance for the teeth-on-stator seal.

Childs, D. W.↗

Experimental rotordynamic coefficient results for teeth-on-rotor and teeth-on-stator labyrinth gas seals

An experimental test facility is used to measure the rotordynamic coefficients of teeth-on-rotor and teeth-on-stator labyrinth gas seals. Direct damping coefficients are presented for these seals for the first time. The results are presented for the two seal configurations at identical operating conditions, and show that, in a rotordynamic sense, the teeth-on-stator seal is more stable than the teeth-on-rotor seal, for inlet tangential velocity in the direction of rotation.

Childs, D. W.↗

An iwatsubo-based solution for labyrinth seals - comparison with experimental results

The basic equations are derived for compressible flow in a labyrinth seal. The flow is assumed to be completely turbulent in the circumferential direction where the friction factor is determined by the Blasius relation. Linearized zeroth and first-order perturbation equations are developed for small motion about a centered position by an expansion in the eccentricity ratio. The zeroth-order pressure distribution is found by satisfying the leakage equation while the circumferential velocity distribution is determined by satisfying the momentum equation. The first-order equations are solved by a separation of variables solution. Integration of the resultant pressure distribution along and around the seal defines the reaction force developed by the seal and the corresponding dynamic coefficients. The results of this analysis are compared to published test results.

Childs, D. W.↗

Theory versus experiment for the rotordynamic coefficients of annular gas seals. Part 1: Test facility and apparatus

A facility and apparatus are described for determining the rotordynamic coefficients and leakage characteristics of annular gas seals. The apparatus has a current top speed of 8000 cpm with a nominal seal diameter of 15.24 cmn (6 in). The air supply unit yields a seal pressure ratio of approximately 7. An external shaker is used to excite the test rotor. The capability to independently calculate all rotordynamic coefficients at a given operating condition with one excitation frequency are discussed.

Childs, D. W.↗