Search NASA⌕ Search

Engineering topics

Scherer, Norbert F.

Publications and source records attributed to Scherer, Norbert F..

Facile Measurement of the Rotation of a Single Optically Trapped Nanoparticle Using the Diagonal Ratio of a Quadrant Photodiode

Optical tweezers are a powerful tool for exploring physical properties of particles in various environments through analysis of their dynamics in a trapping potential. Analysis of the trapped particle's position is often done using interferometric back-focal-plane detection microscopy in which interference between the trapping laser and the light interacting with the trapped particle is projected on a quadrant photo-diode (QPD). The QPD measurements are almost universally the voltage ratios between the transverse components of the detector (left/right; up/down) that are calibrated to ascertain particle positions and orientations (i.e., rotation). In this paper, we demonstrate how measuring the diagonal ratio of the QPD allows tracking the spinning and orbital motion of optically trapped objects with enhanced sensitivity compared to the conventional transverse ratio and reveals additional information about particle dynamics. The diagonal ratio "balances" the signal from opposite sides of the QPD, allowing common mode noise reduction and increased measurement sensitivity of the rotating nanospheres at frequencies from below 200 Hz to above 15 kHz. We show that the variability in particle rotation rates is due to slight differences in the aspect ratio of the nanoparticles. We also measure in situ a gradual acceleration in the spinning frequency of trapped nanoparticles due to photothermal shedding of surface ligands and the resulting decrease of rotational friction in solution. The accelerating particles spin at rates exceeding 30 kHz and are eventually "optically printed" onto the glass coverslip on top of the liquid cell enclosure. The diagonal ratio is a simple, readily available, and powerful enabler for measuring rotational dynamics with a 5-fold sensitivity increase over conventional QPD measurements. This affords opportunities for controlling the orientational dynamics of trapped nanoparticles, which is crucial for various applications, including nanoscale mechanical motors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical matter machines: angular momentum conversion by collective modes in optically bound nanoparticle arrays

The creation of optically powered self-assembling nano-to-meso-scale machines that do work is a long-standing goal in photonics. We demonstrate an optical matter (OM) machine that converts the spin angular momentum (SAM) of light into orbital angular momentum (OAM) to do mechanical work. The specific OM machine we study is based on a sixfold symmetric hexagonally ordered nanoparticle array that operates as an OM “gear” that is assembled and made to rotate in a circularly polarized Gaussian beam. The rotational symmetry of the OM gear leads to a selection rule for the allowed scattering modes based on their angular momentum. Electrodynamics calculations show that the collective scattering modes with the largest angular momentum scatter strongly in the transverse direction. Simulations and experiments show that the angular momentum that accompanies the scattered light causes a “negative torque” response on the OM gear and drives a “probe” particle placed outside the OM gear around the gear in an asymmetric force field analogously to Brownian ratchets. The gear–probe OM machine concept can be expanded to applications in nanofluidics and particle sorting.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Snapshot multifocal light field microscopy

Light field microscopy (LFM) is an emerging technology for high-speed wide-field 3D imaging by capturing 4D light field of 3D volumes. However, its 3D imaging capability comes at a cost of lateral resolution. In addition, the lateral resolution is not uniform across depth in the light field dconvolution reconstructions. To address these problems, here, we propose a snapshot multifocal light field microscopy (MFLFM) imaging method. The underlying concept of the MFLFM is to collect multiple focal shifted light fields simultaneously. We show that by focal stacking those focal shifted light fields, the depth-of-field (DOF) of the LFM can be further improved but without sacrificing the lateral resolution. Also, if all differently focused light fields are utilized together in the deconvolution, the MFLFM could achieve a high and uniform lateral resolution within a larger DOF. We present a house-built MFLFM system by placing a diffractive optical element at the Fourier plane of a conventional LFM. The optical performance of the MFLFM are analyzed and given. Both simulations and proof-of-principle experimental results are provided to demonstrate the effectiveness and benefits of the MFLFM. We believe that the proposed snapshot MFLFM has potential to enable high-speed and high resolution 3D imaging applications.

He, Kuan↗

Excitation of Nonradiating Anapoles in Dielectric Nanospheres

Although the study of nonradiating anapoles has long been part of fundamental physics, the dynamic anapole at optical frequencies was only recently experimentally demonstrated in a specialized silicon nanodisk structure. In this article, we report excitation of the electrodynamic anapole state in isotropic silicon nanospheres using radially polarized beam illumination. The superposition of equal and out-of-phase amplitudes of the Cartesian electric and toroidal dipoles produces a pronounced dip in the scattering spectra with the scattering intensity almost reaching zero-a signature of anapole excitation. The total scattering intensity associated with the anapole excitation is found to be more than 10 times weaker for illumination with radially vs linearly polarized beams. Our approach provides a simple, straightforward alternative path to realizing nonradiating anapole states at the optical frequencies.

36 MATERIALS SCIENCE↗

Nanoscale Resolution 3D Snapshot Particle Tracking by Multifocal Microscopy

Accurate, precise, and rapid particle tracking in three dimensions remains a challenge; yet, its achievement will significantly enhance our understanding of living systems. We developed a multifocal microscopy (MFM) that allows snapshot acquisition of the imaging data, and an associated image processing approach, that together allow simultaneous 3D tracking of many fluorescent particles with nanoscale resolution. The 3D tracking was validated by measuring a known trajectory of a fluorescent bead with an axial accuracy of 19 nm through an image depth (axial range) of 3 pm and 4 nm precision of axial localization through an image depth of 4 pm. A second test obtained a uniform axial probability distribution and Brownian dynamics of beads diffusing in solution. We also validated the MFM approach by imaging fluorescent beads immobilized in gels and comparing the 3D localizations to their "ground truth" positions obtained from a confocal microscopy z-stack of finely spaced images. Finally, we applied our MFM and image processing approach to obtain 3D trajectories of insulin granules in pseudoislets of MIN6 cells to demonstrate its compatibility with complex biological systems. Our study demonstrates that multifocal microscopy allows rapid (video rate) and simultaneous 3D tracking of many "particles" with nanoscale accuracy and precision in a wide range of systems, including over spatial scales relevant to whole live cells.

3D Tracking↗

Hierarchical Assembly of Plasmonic Nanoparticle Heterodimer Arrays with Tunable Sub-5 nm Nanogaps

Nanoparticle assemblies have generated intense interest because of their novel optical, electronic, and magnetic properties that open up numerous opportunities in fundamental and applied nanophotonics, -electronics, and -magnetics. However, despite the great scientific and technological potential of these structures, it remains an outstanding challenge to reliably fabricate such assemblies with both nanometer-level structural control and precise spatial arrangements on a macroscopic scale. It is the combination of these two features that is key to realizing nanoparticle assemblies potential, particular for device applications. To address this challenge, we propose a hierarchical assembly approach consisting of both template-particle and particle-particle interactions, whereby the former ensures precise addressability of assemblies on a surface and the latter provides nanometer-level structural control. Template-particle interactions are harnessed via chemical-pattern-directed assembly, and the particle-particle interactions are controlled using DNA-directed self-assembly. To demonstrate the potential of this hierarchical assembly approach, we demonstrate the fabrication of a particularly fascinating assembly: the nanoparticle heterodimer, which possesses a surprisingly rich set of plasmonic properties and is a promising candidate to enable a variety of imaging and sensing applications. Each heterodimer is placed on the surface at predetermined locations, and the precise control of the nanogaps is confirmed by far-field scattering measurements of individual dimers. We further demonstrate that the gap size can be effectively tuned by varying the DNA length. By correlating measured spectra with finite-difference time-domain (FDTD) simulations, we determine the gap sizes to be 4.2 and 5.0 nm-with subnm deviation-for the two DNA lengths investigated. This is one of the best gap uniformities ever demonstrated for surface-bound nanoparticle assemblies. The estimated surface-enhanced Raman scattering (SERS) enhancement factor of these heterodimers is on the order of 10 5 -10 6 with high reproducibility and predictable polarization-dependence. This hierarchical fabrication technique-employing both template-particle and particle-particle interactions-constitutes a novel platform for the realization of functional nanoparticle assemblies on surfaces and thereby creates new opportunities to implement these structures in a variety of applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Three-dimensional optical trapping and orientation of microparticles for coherent X-ray diffraction imaging

Optical trapping has been implemented in many areas of physics and biology as a noncontact sample manipulation technique to study the structure and dynamics of nano-andmesoscale objects. It provides a unique approach for manipulating microscopic objects without inducing undesired changes in structure. Combining optical trapping with hard X-ray microscopy techniques, such as coherent diffraction imaging and crystallography, provides a nonperturbing environment where electronic and structural dynamics of an individual particle in solution can be followed in situ. It was previously shown that optical trapping allows the manipulation of micrometer-sized objects for Xray fluorescence imaging. However, questions remain over the ability of optical trapping to position objects for X-ray diffraction measurements, which have stringent requirements for angular stability. Our work demonstrates that dynamic holographic optical tweezers are capable of manipulating single micrometer-scale anisotropic particles in a microfluidic environment with the precision and stability required for X-ray Bragg diffraction experiments-thus functioning as an "optical goniometer." The methodology can be extended to a variety of X-ray experiments and the Bragg coherent diffractive imaging of individual particles in solution, as demonstrated here, will be markedly enhanced with the advent of brighter, coherent X-ray sources.

Gao, Yuan↗

Reactive optical matter: light-induced motility in electrodynamically asymmetric nanoscale scatterers

From Newton’s third law, which is known as the principle of actio et reactio, we expect the forces between interacting particles to be equal and opposite for closed systems. Otherwise, “nonreciprocal” forces can arise. This has been shown theoretically in the interaction between dissimilar optically trapped particles that are mediated by an external field. As a result, despite the incident external field not having a transverse component of momentum, the particle pair experiences a force in a direction that is transverse to the light propagation direction. In this letter, we directly measure the net nonreciprocal forces in electrodynamically interacting asymmetric nanoparticle dimers and nanoparticle structures that are illuminated by plane waves and confined to pseudo one-dimensional geometries. We show via electrodynamic theory and simulations that interparticle interactions cause asymmetric scattering from heterodimers. Therefore, the nonreciprocal forces are a consequence of momentum conservation. Our study demonstrates that asymmetric scatterers exhibit directed motion due to the breakdown of mirror symmetry in open systems that involve incident external fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crossover from positive to negative optical torque in mesoscale optical matter

The photons in circularly polarized light can transfer their quantized spin angular momentum to micro- and nanostructures via absorption and scattering. This normally exerts positive torque on the objects wher the sign (i.e., handedness or angular direction) follows that of the spin angular momentum. Here we show that the sign of the optical torque can be negative in mesoscopic optical matter arrays of metal nanoparticles (NPs) assembled in circularly polarized optical traps. Crossover from positive to negative optical torque, which occurs for arrays with different number, separation and configuration of the constituent particles, is shown to result from many-body interactions as clarified by electrodynamics simulations. Our results establish that both positive and negative optical torque can be readily realized and controlled in optical matter arrays. This property and reconfigurability of the arrays makes possible programmable materials for optomechanical, microrheological and biological applications.

36 MATERIALS SCIENCE↗

Snapshot 3D tracking of insulin granules in live cells

Rapid and accurate volumetric imaging remains a challenge, yet has the potential to enhance understanding of cell function. We developed and used a multifocal microscope (MFM) for 3D snapshot imaging to allow 3D tracking of insulin granules labeled with mCherry in MIN6 cells. MFM employs a special diffractive optical element (DOE) to simultaneously image multiple focal planes. This simultaneous acquisition of information deteunines the 3D location of single objects at a speed only limited by the array detector's frame rate. We validated the accuracy of MFM imaging/tracking with fluorescence beads; the 3D positions and trajectories of single fluorescence beads can be detelinined accurately over a wide range of spatial and temporal scales. The 3D positions and trajectories of single insulin granules in a 3.2um deep volume were deteunined with imaging processing that combines 3D decovolution, shift correction, and finally tracking using the Imaris software package. We find that the motion of the granules is super diffusive, but less so in 3D than 2D for cells grown on coverslip surfaces, suggesting an anisotropy in the cytoskeleton (e.g. microtubules and action).

3D tracking↗

Analysis and correction of errors in nanoscale particle tracking using the Single-pixel interior filling function (SPIFF) algorithm

Particle tracking, which is an essential tool in many fields of scientific research, uses algorithms that retrieve the centroid of tracked particles with sub-pixel accuracy. However, images in which the particles occupy a small number of pixels on the detector, are in close proximity to other particles or suffer from background noise, show a systematic error in which the particle sub-pixel positions are biased towards the center of the pixel. This “pixel locking” effect greatly reduces particle tracking accuracy. In this report, we demonstrate the severity of these errors by tracking experimental (and simulated) imaging data of optically trapped silver nanoparticles and single fluorescent proteins. We show that errors in interparticle separation, angle and mean square displacement are significantly reduced by applying the corrective Single-Pixel Interior Filling Function (SPIFF) algorithm. Our work demonstrates the potential ubiquity of such errors and the general applicability of SPIFF correction to many experimental fields.

Science & Technology - Other Topics↗

Rotation and Negative Torque in Electrodynamically Bound Nanoparticle Dimers

Here, we examine the formation and concomitant rotation of electrodynamically bound dimers (EBD) of 150nm diameter Ag nanoparticles trapped in circularly polarized focused Gaussian beams. The rotation frequency of an EBD increases linearly with the incident beam power, reaching high mean values of ~ 4kHz for a relatively low incident power of 14mW. Using a coupled-dipole/effective polarizability model, we reveal that retardation of the scattered fields and electrodynamic interactions can lead to a “negative torque” causing rotation of the EBD in the direction opposite to that of the circular polarization. This intriguing opposite-handed rotation due to negative torque is clearly demonstrated using electrodynamics-Langevin dynamics simulations by changing particle separations and thus varying the retardation effects. Finally, negative torque is also demonstrated in experiments from statistical analysis of the EBD trajectories. These results demonstrate novel rotational dynamics of nanoparticles in optical matter using circular polarization and open a new avenue to control orientational dynamics through coupling to interparticle separation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-pixel interior filling function approach for detecting and correcting errors in particle tracking

We present a general method for detecting and correcting biases in the outputs of particle-tracking experiments. Our approach is based on the histogram of estimated positions within pixels, which we term the single-pixel interior filling function (SPIFF). We use the deviation of the SPIFF from a uniform distribution to test the veracity of tracking analyses from different algorithms. Unbiased SPIFFs correspond to uniform pixel filling, whereas biased ones exhibit pixel locking, in which the estimated particle positions concentrate toward the centers of pixels. Although pixel locking is a well-known phenomenon, we go beyond existing methods to show how the SPIFF can be used to correct errors. Here, the key is that the SPIFF aggregates statistical information from many single-particle images and localizations that are gathered over time or across an ensemble, and this information augments the single-particle data. We explicitly consider two cases that give rise to significant errors in estimated particle locations: undersampling the point spread function due to small emitter size and intensity overlap of proximal objects. In these situations, we show how errors in positions can be corrected essentially completely with little added computational cost. Additional situations and applications to experimental data are explored in SI Appendix. In the presence of experimental-like shot noise, the precision of the SPIFF-based correction achieves (and can even exceed) the unbiased Cramér–Rao lower bound. We expect the SPIFF approach to be useful in a wide range of localization applications, including single-molecule imaging and particle tracking, in fields ranging from biology to materials science to astronomy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗