Determining the Conformation of an Adsorbed Br-PEG-Peptide by Long Period X-Ray Standing Wave Fluorescence
Long-period X-ray standing wave fluorescence (XSW) and X-ray reflectivity techniques are employed to probe the conformation of a Br-poly(ethylene glycol) (PEG)-peptide adsorbate at the hydrated interface of a polystyrene substrate. The Br atom on this Br-PEG-peptide construct serves as a marker atom allowing determination by XSW of its position and distribution with respect to the adsorption surface with angstrom resolution. Adsorption occurs on native or ion-beam-modified polystyrene films that are spin-coated onto a Si substrate and display either nonpolar or polar surfaces, respectively. A compact, oriented monolayer of Br-PEG-peptide can be formed with the peptide end adsorbed onto the polar surface and the PEG end terminating with the Br tag extending into the aqueous phase. The 108-141 {angstrom} distance of the Br atom from the polystyrene surface in this oriented monolayer is similar to the estimated {approx}150 {angstrom} length of the extended Br-PEG-peptide. This Br-polystyrene distance depends on adsorption time and surface properties prior to adsorption. Incomplete multilayers form on the polar surface after sufficient adsorption time elapses. By contrast, adsorption onto the nonpolar surface is submonolayer, patchy, and highly disordered with an isotropic Br distribution. Overall, this combination of X-ray surface scattering techniques with a novel sample preparation strategy has several advantages as a real space probe of adsorbed or covalently bound biomolecules at the liquid-solid interface.
The liquid surface/interface spectrometer at ChemMatCARS synchrotron facility at the Advanced Photon Source
We discuss results from the first experiments on a new liquid surface/interface X-ray spectrometer recently commissioned by ChemMatCARS at Sector 15 of the Advanced Photon Source. These experiments include studies of liquid/liquid interfaces, monolayers supported on the water surface, and liquid metal surfaces.
The width of the water/2-heptanone liquid-liquid interface
Synchrotron X-ray reflectivity is used to study the electron density as a function of depth through the bulk water/2-heptanone interface. The measured interfacial width of 7.0 {+-} 0.2 {angstrom} is comparable to the value calculated from capillary wave theory (7.3 {angstrom}) using the measured interfacial tension of 12.6 mN/m. This result is consistent with capillary wave theory and molecular dynamics simulations that describe a molecularly sharp interface roughened by thermal fluctuations.
Ion distributions at the nitrobenzene-water interface electrified by a common ion
Synchrotron X-ray reflectivity is used to study ion distributions at the liquid-liquid interface between a nitrobenzene solution of tetrabutylammonium tetraphenylborate (TBATPB) and a water solution of tetrabutylammonium bromide (TBABr). The concentration of TBABr is varied to alter the ion distribution. Our X-ray measurements are inconsistent with several commonly used theories of ion distributions, including Gouy-Chapman, modified Verwey-Niessen, and the MPB5 version of the Poisson-Boltzmann equation. These structural measurements are described well by ion distributions predicted by a version of the Poisson-Boltzmann equation that explicitly includes a free energy profile for ion transfer across the interface when this profile is described by a simple analytic form or by a potential of mean force from molecular dynamics simulations. These X-ray measurements from the liquid-liquid interface provide evidence for the importance of interfacial liquid structure in determining interfacial ion distributions.
Structure and Depletion at Fluorocarbon and Hydrocarbon/Water Liquid/Liquid Interfaces
Abstract not provided