Search NASA⌕ Search

Engineering topics

Schmidt, R

Publications and source records attributed to Schmidt, R.

TU-H-CAMPUS-IeP1-02: Validation of a CT Monte Carlo Software

Purpose: To validate the in-house developed CT Monte Carlo calculation tool GMctdospp against reference simulation sets provided by the AAPM in the new report 195. Methods: Deposited energy was calculated in four segments (test 1) and two 10 cm long cylinders (test 2) inside a CTDI phantom (following case #4 of the AAPM report 195). The x-ray point source of a given 120 kVp spectrum was collimated to a fan beam with two thicknesses (10 mm, 80 mm) for a static and a rotational setup. In addition, a given chest geometry was used to calculate deposited energy in several organs for a 0° static and a rotational beam (following case #5 of the AAPM report 195). The results of GMctdospp were compared against the particular mean value of the four quoted Monte Carlo codes (EGSnrc, Geant 4, MCNP and Penelope). Results: Calculated values showed no outliers in any of the cases. Differences between GMctdospp and the particular mean Results: Calculated values showed no outliers in any of the cases. Differences between GMctdospp and the particular mean value were always at similar magnitude compared to the quoted codes. For case #4 (CTDI phantom) the relative differences were within 1.5 %, on average 0.4 % and for case #5 (chest phantom) within 2.5 % and on average 0.85 %. Conclusion: The results confirmed an overall uncertainty of the Monte-Carlo calculation chain in GMctdospp being <2.5 %, for most cases even better. This can be considered small compared to other sources of uncertainties, e.g. virtual source and patient models. The photon transport implemented in GMctdospp inside a voxel-based patient geometry was successfully verified.

60 APPLIED LIFE SCIENCES↗

Electron Doping by Charge Transfer at LaFeO 3 /Sm 2 CuO 4 Epitaxial Interfaces

The breakdown of the lattice translational invariance symmetry that occurs at complex oxide interfaces may profoundly modify their electronic structure, leading to interfacial states with properties drastically different from those of the superlattice individual components. The appearance of a conducting two dimensional (2D) electron gas at the interface between two insulating oxides and induced magnetism in a non-magnetic material are just two among many fascinating examples. [ 1 8 ] One of the key factors underlying novel properties is the modifi cation of the doping and orbital occupancy near those interfaces, which may result from charge transfer processes. [ 3 , 9 11 ] If materials used in heterostructures have different work functions, a non-equilibrium situation will be created at the interface and charge will be transferred until the chemical potential levels off. [ 12 ] The use of such phenomena to modify doping in heterostructures has been proposed theoretically as a new route to avoid the quenched disorder that inevitably accompanies the chemical doping. At the interface between a Mott insulating parent compound of the high critical temperature superconductor (HTSC) family and a suitable material that would act as the charge donor, electron doped phases could be stabilized which would eventually turn metallic and perhaps superconducting. [ 12 , 13 ] Such charge transfer processes have been observed at interfaces involving copper oxides such as La 0.7 Ca 0.3 MnO 3 / YBa 2 Cu 3 O 7 , [ 14 ] La 2 x Sr x CuO 4 /La 2 CuO 4 [ 15 ] and SrTi 1 x Nb x O 3 / Sm 2 CuO 4 . [ 16 ] While a novel 2D superconducting state was found at the La 2-x Sr x CuO 4 /La 2 CuO 4 interface, [ 17 ] the effect of doping by charge transfer could not be examined in the other two cases due to the detrimental effect on the YBa 2 Cu 3 O 7 superconductivity of the spin polarized electrons from La 0.7 Ca 0.3 MnO 3 in one case and due to the conducting nature of the SrTi 1 x Nb x O 3 in the other case, which obscures changes in the conducting properties of the interface layer. In this paper, the structural and

Bruno, Flavio Y.↗

Sodium Fast Reactor Safety and Licensing Research Plan – Volume II

Expert panels comprised of subject matter experts identified at the U.S. National Laboratories (SNL, ANL, INL, ORNL, LBL, and BNL), universities (University of Wisconsin and Ohio State University), international agencies (IRSN, CEA, JAEA, KAERI, and JRC-IE) and private consultation companies (Radiation Effects Consulting) were assembled to perform a gap analysis for sodium fast reactor licensing. Expert-opinion elicitation was performed to qualitatively assess the current state of sodium fast reactor technologies. Five independent gap analyses were performed resulting in the following topical reports: (1) Accident Initiators and Sequences (i.e., Initiators/Sequences Technology Gap Analysis), (2) Sodium Technology Phenomena (i.e., Advanced Burner Reactor Sodium Technology Gap Analysis), (3) Fuels and Materials (i.e., Sodium Fast Reactor Fuels and Materials: Research Needs), (4) Source Term Characterization (i.e., Advanced Sodium Fast Reactor Accident Source Terms: Research Needs), and (5) Computer Codes and Models (i.e., Sodium Fast Reactor Gaps Analysis of Computer Codes and Models for Accident Analysis and Reactor Safety). Volume II of the Sodium Research Plan consolidates the five gap analysis reports produced by each expert panel, wherein the importance of the identified phenomena and necessities of further experimental research and code development were addressed. The findings from these five reports comprised the basis for the analysis in Sodium Fast Reactor Research Plan Volume I.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tailoring Interface Structure in Highly Strained YSZ/STO Heterostructures

Heterostructures combining transition metal oxides, as compared to other materials, are able to accommodate very large amounts of epitaxial strain without breaking into islands or structural domains. Coherently strained interfaces are an interesting playground for the search of materials with enhanced ion diffusivities, of interest in devices for energy generation and storage. In this work we highlight the importance of the interface structure of highly strained YSZ/STO superlattices in determining an enhancement of their ionic conductivity. We show the role of growth orientation in controlling the structure and morphology of the interface. Results of density functional theory calculations are discussed, showing that the incompatibility of the oxygen positions at the interface planes plays a key role in stabilizing the high values of ionic conductivities.

36 MATERIALS SCIENCE↗

Summary of working group g: beam material interaction

For the first time, the workshop on High-Intensity and High-Brightness Hadron Beams (HB2010), held at Morschach, Switzerland and organized by the Paul Scherrer Institute, included a Working group dealing with the interaction between beam and material. Due to the high power beams of existing and future facilities, this topic is already of great relevance for such machines and is expected to become even more important in the future. While more specialized workshops related to topics of radiation damage, activation or thermo-mechanical calculations, already exist, HB2010 provided the occasion to discuss the interplay of these topics, focusing on components like targets, beam dumps and collimators, whose reliability are crucial for a user facility. In addition, a broader community of people working on a variety of issues related to the operation of accelerators could be informed and their interest sparked.

43 PARTICLE ACCELERATORS↗

ULTRA-COMPACT ACCELERATOR TECHNOLOGIES FOR APPLICATION IN NUCLEAR TECHNIQUES

We report on compact accelerator technology development for potential use as a pulsed neutron source quantitative post verifier. The technology is derived from our on-going compact accelerator technology development program for radiography under the US Department of Energy and for a clinic sized compact proton therapy systems under an industry sponsored Cooperative Research and Development Agreement. The accelerator technique relies on the synchronous discharge of a prompt pulse generating stacked transmission line structure with the beam transit. The goal of this technology is to achieve approx10 MV/m gradients for 10 s of nanoseconds pulses and approx100 MV/m gradients for approx1 ns systems. As a post verifier for supplementing existing x-ray equipment, this system can remain in a charged, stand-by state with little or no energy consumption. We describe the progress of our overall component development effort with the multilayer dielectric wall insulators (i.e., the accelerator wall), compact power supply technology, kHz repetition-rate surface flashover ion sources, and the prompt pulse generation system consisting of wide-bandgap switches and high performance dielectric materials.

43 PARTICLE ACCELERATORS↗

Three-body loss in lithium from functional renormalization

We use functional-integral methods for an estimate of the three-body loss in a three-component {sup 6}Li ultracold atom gas. We advocate a simple picture where the loss proceeds by the formation of a three-atom bound trimer state, the trion. In turn, the effective amplitude for the trion formation from three atoms is estimated from a simple effective boson exchange process. The energy gap of the trion and other key quantities for the loss coefficient are computed in a functional renormalization-group framework.

74 ATOMIC AND MOLECULAR PHYSICS↗

Methods to detect faulty splices in the superconducting magnet system of the LHC

The incident of 19 September 2008 at the LHC was caused by a faulty inter-magnet splice of about 200 n{Omega} resistance. Cryogenic and electrical techniques have been developed to detect other abnormal splices, either between or inside the magnets. The existing quench protection system can be used to detect internal splices with R > 20 n{Omega}. Since this system does not cover the bus between magnets, the cryogenic system is used to measure the rate of temperature rise due to ohmic heating. Accuracy of a few mK/h, corresponding to a few Watts, has been achieved, allowing detection of excess resistance, if it is more than 40 n{Omega} in a cryogenic subsector (two optical cells). Follow-up electrical measurements are made in regions identified by the cryogenic system. These techniques have detected two abnormal internal magnet splices of 100 n{Omega} and 50 n{Omega} respectively. In 2009, this ad hoc system will be replaced with a permanent one to monitor all splices at the n{Omega} level.

43 PARTICLE ACCELERATORS↗