Engineering topics
Schmidt, Tyler
Publications and source records attributed to Schmidt, Tyler.
Novel concept for detection of a fluid flow fault in a pumped fluid heat rejection system
A pumped fluid heat rejection system (HRS) requires continuous flow of the working fluid to ensure that the components controlled by the HRS stay within their allowable temperature limits. An interruption of flow could result in violations of hardware qualification limits and mission failure. Some of these violations can happen within a few hours. Hence, quick detection of a flow fault to invoke mitigation measures is very critical. In typical pumped fluid HRS, dual or triple pumps are employed to switch the backup units in case the primary unit were to fail. The key metric for the selection of a fault detection system is that it should detect the fault much before the fault’s impact on the thermal health of the HRS controlled components is realized. A trade study was conducted to select such a system for the Europa Clipper Mission to Europa, a moon of Jupiter that is planned for a launch in 2023. Out of the several concepts studied, the most attractive one was a novel and simple concept that uses a low power film heater attached to a section of the HRS tubing. While the fluid flows at its nominal rate, the high thermal coupling of the flowing fluid leads to the tube being close to the fluid’s temperature. However, when the flow stops, the heater warms the small thermal mass of the tubing to a high temperature in a short span of time (~15 minutes). This large temperature rise would then imply that the flow must have stopped. This paper will describe the various concepts considered, the chosen concept, its implementation, and the results of developments tests to validate its performance.
Thermal control technologies for Europa Clipper mission
The Europa Clipper Mission to Europa, a moon of Jupiter, is planned for a launch in 2023. Since Europa is at a large distance (5.6 A.U.) from the Sun, the solar flux is less than 4% of that at Earth. This requires very large solar arrays to meet the power demands of a typical new mission concept. Hence, conservation of power for use in thermal control is extremely important. To achieve this goal a mechanically pumped fluid loop heat rejection system (HRS) is utilized to harvest waste heat from the spacecraft components. In addition to this, several thermal control technologies are employed. They include a high performance dual Multi-Layer Insulation (MLI) blanket design to minimize the large majority of heat loss from the spacecraft; two passive thermal control valves in series to greatly reduce the heat loss from the HRS to its radiator; and a low temperature louver to further reduce the loss from the radiator. This paper will describe these technologies, schemes for their implementation, and results of development tests to validate their performance.
A Dual Multilayer Insulation Blanket Concept to Radically Reduce Heat Loss From Thermally Controlled Spacecraft and Instruments
At large distances from the Sun (e.g. Jupiter/Saturn), the solar flux is less than 4% that at Earth. This requires very large solar arrays to meet the power demands of a typical new mission concept. Heat loss through Multi-Layer Insulation (MLI) blankets typically constitutes the vast majority of the total heat loss. Hence, improvements to MLI blankets that reduce heat loss are advantageous to the spacecraft design. The overall effective emittance (ε*) of MLI is usually a range dependent on the number of layers, size of blanket, seams, feedthroughs, layer density and operating temperatures of the heat source and heat sink. A concept has been developed at JPL to reduce the ε* by as much as a factor of two, which produces a corresponding reduction in heat losses. This concept utilizes two MLI blankets physically separated by traditional bumpers or spacers used for micrometeoroid protection. The outer surface of the inner blanket and the inner surface of the outer blanket are low emissivity surfaces to further minimize the total ε* of the overall dual MLI system. Analytical predictions of a dual MLI concept have been made using test data based ε* correlations. A development test has been conducted to validate the dual blanket design’s performance. This paper will describe the dual blanket design concept, schemes for its implementation, and the corresponding test results to validate its performance.