Search NASA⌕ Search

Engineering topics

Schmookler, Barak

Publications and source records attributed to Schmookler, Barak.

A few-degree calorimeter for the future electron-ion collider

In this study, measuring the region 0.1 < Q 2 < 1.0 GeV 2 is essential to support searches for gluon saturation at the future Electron-Ion Collider. Recent studies have revealed that covering this region at the highest beam energies is not feasible with current detector designs, resulting in the so-called Q 2 gap. In this work, we present a design for the Few-Degree Calorimeter (FDC), which addresses this issue. The FDC uses SiPM-on-tile technology with tungsten absorber and covers the range of -4.6 < η < -3.6. It offers fine transverse and longitudinal granularity, along with excellent time resolution, enabling standalone electron tagging. Our design represents the first concrete solution to bridge the Q 2 gap at the EIC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of the strong coupling with HERA and EIC inclusive data

Sensitivity to the strong coupling $∝$ s ($M^{2}_{Z}$) is investigated using existing Deep Inelastic Scattering data from HERA in combination with projected future measurements from the Electron Ion Collider (EIC) in a next-to-next-to-leading order QCD analysis. A potentially world-leading level of precision is achievable when combining simulated inclusive neutral current EIC data with inclusive charged and neutral current measurements from HERA, with or without the addition of HERA inclusive jet and dijet data. The result can be obtained with substantially less than one year of projected EIC data at the lower end of the EIC centre-of-mass energy range. Some questions remain over the magnitude of uncertainties due to missing higher orders in the theoretical framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider

Herein we present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear over the energy range of interest for the EIC. Its energy resolution meets the requirements set in the EIC Yellow Report even with a basic reconstruction algorithm. Moreover, this detector will provide 5D shower data (position, energy, and time), which can be exploited with machine-learning techniques. This detector concept has the potential to unleash the power of imaging calorimetry at the EIC to enable measurements at extreme kinematics in electron–proton and electron–nucleus collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗