Search NASA⌕ Search

Engineering topics

Schneider, Mitchell

Publications and source records attributed to Schneider, Mitchell.

The Need for Nb3Sn Coated Cu Cavities for Future Accelerators

Based on current efforts in the U.S. on the novel concept of parallel-feed RF accelerator structures, and in the U.S. and abroad in producing Nb3Sn films on either Cu or bronze, we rec-ommend that the Particle Physics community foster R&D in Superconducting Nb3Sn coated Cu RF Cavities instead of costly bulk Nb. The paper includes methods to process the coated cavi-ties at temperatures consistent with Cu retaining its shape. A devoted global effort in develop-ing Cu cavity structures coated with Nb3Sn would make the ILC or Higgs factories more afforda-ble and more likely to be built. Not only do parallel-feed RF structures enable both higher ac-celerating gradients and higher efficiencies, but they would be applicable to both Cu and Nb3Sn coated Cu cells. Increased effort on these two techniques would synergize expenditures to-wards progress, which will converge on the choice of technology for the RF of an ILC or any fu-ture accelerator. The current methods of Nb3Sn coatings on Cu or bronze can be geared also towards standard cavity cells. In conclusion, the use of distributed coupling structure topology within improved performance parameters together with Nb3Sn coating technology can lead to a paradigm shift for superconducting linacs, with higher gradient, higher temperature of opera-tion, and reduced overall costs for any future collider.

43 PARTICLE ACCELERATORS↗

High gradient off-axis coupled C-band Cu and CuAg accelerating structures

Here, we report the high gradient testing results of two single-cell off-axis coupled standing wave accelerating structures. Two brazed standing wave off-axis coupled structures with the same geometry were tested: one made of pure copper (Cu) and one made of a copper–silver (CuAg) alloy with a silver concentration of 0.08%. A peak surface electric field of 450 MV/m was achieved in the CuAg structure for a klystron input power of 14.5 MW and a 1 μs pulse length, which was 25% higher than the peak surface electric field achieved in the Cu structure. The superb high gradient performance was achieved because of the two major optimizations in the cavity's geometry: (1) the shunt impedance of the cavity was maximized for a peak surface electric field to accelerating gradient ratio of ~2 for a fully relativistic particle, and (2) the peak magnetic field enhancement due to the input coupler was minimized to limit pulse heating. These tests allow us to conclude that C-band accelerating structures can operate at peak fields similar to those at higher frequencies while providing a larger beam iris for improved beam transport.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗