Search NASA⌕ Search

Engineering topics

Schneider, S. J.

Publications and source records attributed to Schneider, S. J..

Catalyzed Combustion In Micro-Propulsion Devices: Project Status

In recent years, there has been a tendency toward shrinking the size of spacecraft. New classes of spacecraft called micro-spacecraft have been defined by their mass, power, and size ranges. Spacecraft in the range of 20 to 100 kg represent the class most likely to be utilized by most small sat users in the near future. There are also efforts to develop 10 to 20 kg class spacecraft for use in satellite constellations. More ambitious efforts will be to develop spacecraft less than 10 kg, in which MEMS fabrication technology is required. These new micro-spacecraft will require new micro-propulsion technology. Although micro-propulsion includes electric propulsion approaches, the focus of this proposed program is micro-chemical propulsion which requires the development of microcombustors. As combustors are scaled down, the surface to volume ratio increases. The heat release rate in the combustor scales with volume, while heat loss rate scales with surface area. Consequently, heat loss eventually dominates over heat release when the combustor size becomes smaller, thereby leading to flame quenching. The limitations imposed on chamber length and diameter has an immediate impact on the degree of miniaturization of a micro-combustor. Before micro-combustors can be realized, such a difficulty must be overcome. One viable combustion alternative is to take advantage of surface catalysis. Micro-chemical propulsion for small spacecraft can be used for primary thrust, orbit insertion, trajectory-control, and attitude control. Grouping micro-propulsion devices in arrays will allow their use for larger thrust applications. By using an array composed of hundreds or thousands of micro-thruster units, a particular configuration can be arranged to be best suited for a specific application. Moreover, different thruster sizes would provide for a range of thrust levels (from N s to mN s) within the same array. Several thrusters could be fired simultaneously for thrust levels higher than the basic units, or in a rapid sequence in order to provide gradual but steady low-g acceleration. These arrays of micro-propulsion systems would offer unprecedented flexibility and redundancy for satellite propulsion and reaction control for launch vehicles. A high-pressure bi-propellant micro-rocket engine is already being developed using MEMS technology. High pressure turbopumps and valves are to be incorporated onto the rocket chip . High pressure combustion of methane and O2 in a micro-combustor has been demonstrated without catalysis, but ignition was established with a spark. This combustor has rectangular dimensions of 1.5 mm by 8 mm (hydraulic diameter 3.9 mm) and a length of 4.5 mm and was operated at 1250 kPa with plans to operate it at 12.7 MPa. These high operating pressures enable the combustion process in these devices, but these pressures are not practical for pressure fed satellite propulsion systems. Note that the use of these propellants requires an ignition system and that the use of a spark would impose a size limitation to this micro-propulsion device because the spark unit cannot be shrunk proportionately with the thruster. Results presented in this paper consist of an experimental evaluation of the minimum catalyst temperature for initiating/supporting combustion in sub-millimeter diameter tubes. The tubes are resistively heated and reactive premixed gases are passed through the tubes. Tube temperature and inlet pressure are monitored for an indication of exothermic reactions and composition changes in the gases.

Sung, C. J.↗

Achromatic Emission Velocity Measurements in Luminous Flows

A new velocity measurement instrument for luminous flows was developed by Science Research Laboratory for NASA. The SIEVE (Segmented Image Emission VElocimeter) instrument uses broadband light emitted by the flow for the velocity measurement. This differs from other velocimetry techniques in that it does not depend on laser illumination and/or light scattering from particles in the flow. The SIEVE is a passive, non-intrusive diagnostic. By moving and adjusting the imaging optics, the SIEVE can provide three-dimensional mapping of a flow field and determine turbulence scale size. A SIEVE instrument was demonstrated on an illuminated rotating disk to evaluate instrument response and noise and on an oxy-acetylene torch to measure flame velocities. The luminous flow in rocket combustors and plumes is an ideal subject for the SIEVE velocity measurement technique.

Schneider, S. J.↗

Spectrally resolved Rayleigh scattering diagnostic for hydrogen-oxygen rocket plume studies

A Rayleigh scattering diagnostic has been developed to measure gas density, temperature, and velocity in the exhaust plume of 100 N thrust class hydrogen-oxygen rockets. The spectrum of argon-ion laser light scattered by the gas molecules in the plume (predominantly water vapor) is measured with a scanning Fabry-Perot interferometer. The gas density is determined from the total scattered power, the gas temperature from the spectral width, and the velocity from the shift in the peak of the spectrum from the frequency of the incident laser light. The diagnostic has been demonstrated in a rocket test cell and a discussion of results is given.

Seasholtz, R. G.↗

A life test of a 22-Newton (5-lbf) hydrazine rocket

Life tests were conducted on a 22-N (5-lb) hydrazine rocket thruster which incorporates the latest technology to obtain long life from the catalyst bed. A spring mechanism surrounding the catalyst bed continually applies compression to the catalyst bed to prevent the formation of any void channels. The research rocket thruster was tested over an operational cycle of both steady state and pulse firing which simulated a possible space station duty cycle. The thruster ran as expected for about 40 hours, or 3.2 times 10 to the 6th power N-sec (7.2 times 10 to the 5th power lb-sec) total impulse. Subsequently, some thrust chamber pressure decreases were noted during long steady state test periods. After 60.2 hours of run time, tests had to be terminated due to a blockage in the propellant injector tube which occurred during heating of the thruster by a heat lamp. A chemical analysis of the catalyst indicated that iron and nickel metals had poisoned some of the catalyst, thereby causing a degradation in performance. It was determined that a contaminated barrel of hydrazine was the source of the metal poisoning.

Meng, P. R.↗

Measurements of natural circulation flow in a scale model PWR reactor system during postulated degraded core accidents using laser anemometry

The natural circulation of a single-phase fluid in a scale-model pressurized water reactor system was studied during a postulated degraded core accident. A half section of a one-seventh scale model with a plexiglass adiabatic window was employed. Water and SF6 were used as the fluid. LDA was used to perform velocity measurements along the center plane of the model at five elevations. It was found that the recirculation flow patterns are nearly symmetric except near the hot legs and in the upper head and that the fluid in the upper plenum is well mixed.

Kadambi, J. R.↗

Laser anemometry measurements of natural circulation flow in a scale model PWR reactor system

The natural circulation of a single phase fluid in a scale model of a pressurized water reactor system during a postulated grade core accident is analyzed. The fluids utilized were water and SF6. The design of the reactor model and the similitude requirements are described. Four LDA tests were conducted: water with 28 kW of heat in the simulated core, with and without the participation of simulated steam generators; water with 28 kW of heat in the simulated core, with the participation of simulated steam generators and with cold upflow of 12 lbm/min from the lower plenum; and SF6 with 0.9 kW of heat in the simulated core and without the participation of the simulated steam generators. For the water tests, the velocity of the water in the center of the core increases with vertical height and continues to increase in the upper plenum. For SF6, it is observed that the velocities are an order of magnitude higher than those of water; however, the velocity patterns are similar.

Kadambi, J. R.↗