Search NASA⌕ Search

Engineering topics

Schnopper, H.

Publications and source records attributed to Schnopper, H..

X-Ray and Gamma-Ray Astronomy with NTD Germanium-based Microcalorimeters

We report on the performance of our NTD-Ge microcalorimeters. To date, the spectral resolution for x-ray and gamma-ray lines from radioactive sources and laboratory plasmas is 4.8 eV in the entire 1 - 6 keV band and 52 eV at 60 keV. Technical details responsible for this performance are presented as well as an innovative electro-thermal approach for enhancing count-rate capability.

Silver, E.↗

B-MINE: The Balloon-Borne Microcalorimeter Nuclear Line Explorer

B-MINE is a concept for a balloon mission designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the extent and velocity distribution of the 44Ti emitting region. The payload introduces the concept of focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics. B-MINE has a thin, plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3 sigma sensitivity in 10 (exp 6) s of 3.3 x 10(exp -7) ph cm(exp -2) s(exp -1) at 68 keV. During the course of a long duration balloon flight, B-MINE could carry out a detailed study of the 44Ti emission line centroid and width in CAS A.

Silver, E.↗

The Constellation-X Focal Plane Microcalorimeter Array: An NTD-Germanium Solution

The hallmarks of Neutron Transmutation Doped (NTD) germanium cryogenic thermistors include high reliability, reproducibility, and long term stability of bulk carrier transport properties. Using micro-machined NTD Ge thermistors with integral 'flying' leads, we can now fabricate two-dimensional arrays that are built up from a series of stacked linear arrays. We believe that this modular approach of building, assembling, and perhaps replacing individual modules of detectors is essential to the successful fabrication and testing of large multi-element instruments. Details of construction are presented.

Beeman, J.↗

Laboratory Astrophysics and Microanalysis with NTD-Germanium-Based X-Ray Microcalorimeter

With the ability to create cosmic plasma conditions in the laboratory it is possible to investigate the dependencies of key diagnostic X-ray lines on density, temperature, and excitation conditions that exist in astrophysical sources with X-ray optics and a high resolution x-ray microcalorimeter. The same instrumentation can be coupled to scanning electron microscopes or x-ray fluorescence probes to analyze the elemental and chemical composition of electronic, biological, geological and particulate materials. We describe how our microcalorimeter and x-ray optics provide significantly improved capabilities for laboratory astrophysics and microanalysis.

Silver, E.↗

High-resolution X-ray spectroscopy of M87 with the Einstein observatory - The detection of an O VIII emission line

The paper deals with high-resolution X-ray spectroscopy performed to study the extended source surrounding the giant elliptical galaxy, M87, in the Virgo cluster. From observations carried out with a focal plane crystal spectrometer, L-alpha emission was detected from hydrogenic oxygen (O VIII). Upper limits could be set on lines from intermediate ionization states of iron. The presence of a quantity of cooler matter surrounding M87 was revealed, which has important implications for cluster models and favors a radiatively controlled accretion mechanism.

Canizares, C. R.↗

Recurrent brief X-ray bursts from the globular cluster NGC 6624

Observational data are presented on ten brief X-ray bursts, recurrent at nearly equal time intervals, recorded during a two-day observation of 3U 1820-30 in the globular cluster NGC 6624 with the wide-field modulation collimator detectors on the SAS-3 X-ray observatory. The occurrence times were fitted by least squares to a linear sequence with an rms deviation of 621 sec, corresponding to a phase jitter of 3.9%. The bursts were observed in two energy channels. For a sequence of five of the most clearly observed bursts, the 2-6 keV rate rose to its peak value in about 1 sec and then decayed to preburst level in about 10 sec. The 6-11 keV rate rose more slowly and decayed similarly. The smooth decay of their averaged light curve suggests the temporal evolution may have a geometrical origin, where Compton scattering in a surrounding cloud of hot plasma stretches the pulse out and causes a progressive hardening of the spectrum.

Clark, G. W.↗

ANS observations of Cygnus X-1

Cygnus X-1 was observed from 3 November until 9 November 1974, using the hard X-ray (1-28 keV) and soft X-ray (1-8 keV) experiment on board the Astronomical Netherlands Satellite. On three occasions, on 4 and 5 November, the X-ray spectrum was observed to be harder, while the flux intensity in the 1-7 keV ranges decreased by about 50% from its quiescent value. These events occurred near and following the time of superior conjunction of the likely optical counterpart HDE 226 868. These events appear to be the same as previously reported absorption dips and reveal this phenomenon to be more complex than had been believed. A systematic study of the X-ray spectral variations in these energy bands, on a time scale of 64 seconds over the period of the spectroscopic binary, is presented.

Parsignault, D. R.↗

Improved position for the X-ray source associated with the globular cluster NGC 6441

The X-ray source 3U 1746-37 was observed by the hard X-ray experiment on the Astronomical Netherlands Satellite (ANS) in March and September 1975. The one-dimensional position band (+ or - 2 arcmin, 90% confidence) obtained reduces the Uhuru error-box area by a factor of 3 and includes the nucleus of the globular cluster NGC 6441.

Grindlay, J. E.↗

Discovery of intense X-ray bursts from the globular cluster NGC 6624

A new type of time variation of cosmic X-ray sources has been found from the Astronomical Netherlands Satellite (ANS) observations of the source 3U 1820-30, associated with the globular cluster NGC 6624. Two bursts in the 1-30 keV X-ray intensity of this source are reported. Each displayed a rapid rise in flux (no more than 1 s) by a factor of 20-30 followed by an approximately 8-s exponential decay. These bursts appear to be qualitatively different from short time variations previously reported for X-ray sources. Analysis for further source variability, energy spectra, and position is presented. The characteristics of these events may imply the existence of a collapsed core in the globular cluster.

Grindlay, J.↗

The Hard X-ray experiment on the Astronomical Netherlands Satellite

The Hard X-ray Experiment flown on the Astronomical Netherlands Satellite is described. The instrument consists of two parts. One is a large-area detector of about 60 sq cm in total area, sensitive in the energy range between 1.5 and 30 keV. Two counters comprise this detector, each collimated 10 min by 3 deg and offset in the narrow direction by 4 min. The other part is a Bragg-crystal assembly consisting of two PET crystals and counters aligned to search for the silicon emission lines near 2 keV. Instrument characteristics and orbital operations are described.

Gursky, H.↗

X-ray observations of Cyg X-1 with ANS

The equipment, method and results of the measurements performed with soft and hard X-ray detectors of the Space Research Laboratory in Utrecht and the Center for Astrophysics in Cambridge, Mass., are described. Cyg X-1 underwent an upward transition in its intensity, that seems to be the inverse of the downward transition seen by Uhuru in April 1971. The bulk of the increase, as observed by the Astronomical Netherlands Satellite instruments, from May 1 to May 8, 1975, occurs at low energy: between 1 and 2 keV, the intensity increased by a factor of 10 over the November 1974 intensity, while above 8 keV there is no significant change. The data suggest that Cyg X-1 has reverted to its high state.

Heise, J.↗