Search NASA⌕ Search

Engineering topics

Schroeder, Nathan

Publications and source records attributed to Schroeder, Nathan.

Particle Vertical Mixing and Horizontal Conveyance Within an Ambient Temperature Fluidized Bed

Previous studies have shown the advantages of particle-to-sCO2 fluidized bed (FB) heat exchangers, which include high heat transfer coefficients, low material cost, and the ability to horizontally convey solid particles. This paper outlines the design and testing of a compact cold flow FB test apparatus to characterize horizontal conveyance through convolutions within a 100 kWth FB heat exchanger design. Horizontal conveyance is an advantage in FBs because it enables more compact designs for heat exchangers. Two mass flow rates, 0.5 & 1 kg/s, at the inlet & outlet of the FB. To determine consistency of the flow rates, Student’s t-tests were used to assess whether the inlet & outlet values were statistically similar. The mass flow rate exiting the bed was statistically similar to the flow rate entering the bed for both cases, but each case featured a wider range and standard deviation. The range and standard deviation of the 1 kg/s flow rate was 0.69-1.23 kg/s and 0.12 kg/s respectively, and the 0.5 kg/s test featured a range and standard deviation of 0.37-0.73 kg/s and 0.09 kg/s, respectively. These measurements provide confidence that large-scale designs can successfully horizontally convey particles at ````~1.5x minimum fluidization velocity (U­mf) without significant variation in flow rate. A method to characterize the degree of particle vertical mixing and bubble frequency within the FB is also introduced. By using a high-resolution camera together with particle velocimetry, particle motion in the X and Y directions can be estimated to assess bed mixing and bubble frequency.

Khalaf, Jawad↗

Flux Sensor Measurement and Calibration Requirements for High-Intensity Heat Flux Applications: A Trade Study

Stakeholders of CSP and non-CSP high-intensity broadband flux measurements were surveyed and interviewed to obtain flux sensor design and calibration requirements. Existing sensor technologies and existing calibration facilities were then compared against this standard. Stakeholders require a flux sensor designed for >5,000 kW/m2 flux measurements, >1,000 life cycles, <500 ms response time, >60-minute exposure at maximum flux, and <5% measurement uncertainty. Stakeholders also require a sensor with minimal cost, short procurement lead time, and a high-intensity broadband flux calibration. Commercial CSP stakeholders primarily rely on infrared (IR) temperature measurements of receiver equipment to control CSP plant process operation, whereas CSP research and development (R&D) and non-CSP stakeholders rely on accurate flux gauge measurements for a variety of applications. It was determined that existing flux sensor technologies and calibration facilities do not comprehensively meet stakeholder needs. This study suggests a more robust circular foil gauge with a high-intensity solar flux calibration comprehensively meets stakeholder flux measurement needs. Improved circular foil gauge designs and an improved flux sensor calibration facility are discussed.

McLaughlin, Luke (ORCID:0000000303711310)↗

Design of a High Flux Beam Characterization Device for Falling Particle Receivers

This paper outlines the design and error analysis for a flux characterization device (i.e. flux wand) which traverses the aperture of a falling particle receiver cavity providing the incident power measurement needed for the calculation of receiver efficiency without significantly disrupting receiver output. The design features a linear actuator, water cooled extension arm, and refractory bar. The refractory bar/flux wand is a diffusely reflective surface which reflects light as it is translated across the receiver aperture to provide a light intensity distribution that is correlated to a measured flux. The component sizing, constrained by a typical 30 frame per second camera and a 4-point average of the measured reflectance, is presented. Simulation reveals the error that results from a 5% variation in flux wand reflectance is within 4% of the true value.

Schroeder, Nathan↗

Cyclic Thermal and Structural Testing of a Hot Particle Storage Bin

Thermal energy storage is a key element in concentrating solar energy systems. In 2017 a Roadmap toward a third-generation system that could meet the SunSHOT goals of 0.06 $/kWe recommended increasing temperatures to > 700° C for heat transfer media to in-crease thermal efficiencies and lower levelized costs of heat. In 2021, the U.S. Department of Energy selected the particle pathway, G3P3, to build a 1 MWt prototype solar tower with 6 MWh thermal energy storage at the NSTTF in Albuquerque, NM. Of the primary components, the falling particle receiver, and particle-to-sCO2 heat exchanger have been demonstrated at the 250 kWt capacity. The storage component is now being demonstrated as part of the G3P3-USA and G3P3-KSA pilot plants. Storage bin liner materials have been demonstrated by KSU in 2016 and 2019. A flowing particle storage container was demonstrated in 2020 by KSU. The testing presented in this work will be the first to test the particle to wall interactions with mono-lithic refractory insulation, and to validate a transient thermal transport model with the unique kinetics of bulk solids in funnel-flow where cooler particles near the walls flow inward toward a hot central flow channel. This work will also de-risk and characterize the specific design of the G3P3-USA storage bin.

Sment, Jeremy↗

Development of the Generation 3 Particle Pilot Plant Falling Particle Receiver

A falling particle receiver (FPR) has been designed to integrate with the G3P3-USA pilot plant currently being constructed at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories. This receiver integrates several innovative design features including a converging tunnel (SNOUT), an optimized cavity geometry, and a multistage “catch-and-release” trough. Details about the integration of these features and the final G3P3-USA FPR design and construction are described. Ray-tracing models of the FPR utilizing the NSTTF heliostat field are developed leveraging previous modeling efforts using SolTrace. Models demonstrate that at least 1.5 MWth of incident radiative energy can be provided to the FPR on a clear day throughout a typical year in Albuquerque, NM. Spillage fluxes around the periphery of the aperture are within acceptable bounds for the majority of the year. Intercept factors are computed for each utilized heliostat at the Vernal equinox to provide guidance to heliostat operators during operation of the system.

Mills, Brantley↗

Silicon carbide fiber composite receiver tubes manufactured by PIP process

The performance of SiC fiber composites made by a polymer infiltration and pyrolysis (PIP) process was investigated. Two types of tubular composites were manufactured using Hi-Nicalon and Nicalon-CG silicon carbide fibers infiltrated with SMP10 silicon carbide matrix. The fiber content in both composites was about 25 vol.% with an average density of 2.39 g/cc. The tubular SiC composites showed stable solar absorptance and emittance of 0.97 and 0.91, respectively, at 800 °C. The composites were thermally shocked at 900, 1000, and 1100 °C with a waterjet simulating raindrops. As a result, the hoop tensile strength of the composites revealed no loss of mechanical strength due to the thermal shock experiments up to 1100 °C.

14 SOLAR ENERGY↗

Solar optical performance of SiC receiver tubes

As part of a DOE Small Business Innovative Research (SBIR) project, CTP explored options to enhance the solar optical properties of its solar receiver tube. Sandia National Laboratories (Sandia) working with CTP, performed high-flux solar simulator tests on several receiver-tube specimens. Furthermore, the results demonstrated the excellent durability and optical performance of SiOC composite receiver tubes at 800°C surface temperatures.

14 SOLAR ENERGY↗