Schuster, Manfred

Publications and source records attributed to Schuster, Manfred.

Signal-to-noise ratio in x ray dark-field imaging using a grating interferometer

In this work, we report an analytical and experimental investigation of the signal-to-noise ratio for a recently developed method called x ray dark-field imaging. Our approach is based on the propagation of signal and noise through the reconstruction algorithm. We find that the statistical nature of the dark-field images can be understood by a Rician distribution. The analysis shows that, for high flux, the noise in the dark-field images is proportional to the noise in the raw data. In the limit of low flux and, thus, low signal-to-noise ratio, the dark-field signal exhibits a breakdown of the signal transmission, which can be described by an asymptotic behavior of the underlying noise distribution. In this limit, the dark-field signal is no longer connected to the coherence degradation, but rather to the attenuation in the sample. The model is verified in exemplary test measurements using a compact laboratory setup with a polychromatic source and a photon counting detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam hardening effects in grating-based x-ray phase-contrast imaging

Purpose: In this work, the authors investigate how beam hardening affects the image formation in x-ray phase-contrast imaging and consecutively develop a correction algorithm based on the results of the analysis. Methods: The authors' approach utilizes a recently developed x-ray imaging technique using a grating interferometer capable of visualizing the differential phase shift of a wave front traversing an object. An analytical description of beam hardening is given, highlighting differences between attenuation and phase-contrast imaging. The authors present exemplary beam hardening artifacts for a number of well-defined samples in measurements at a compact laboratory setup using a polychromatic source. Results: Despite the differences in image formation, the authors show that beam hardening leads to a similar reduction of image quality in phase-contrast imaging as in conventional attenuation-contrast imaging. Additionally, the authors demonstrate that for homogeneous objects, beam hardening artifacts can be corrected by a linearization technique, applicable to all kinds of phase-contrast methods using polychromatic sources. Conclusions: The evaluated correction algorithm is shown to yield good results for a number of simple test objects and can thus be advocated in medical imaging and nondestructive testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inverse geometry for grating-based x-ray phase-contrast imaging

Phase-contrast imaging using conventional polychromatic x-ray sources and grating interferometers has been developed and demonstrated for x-ray energies up to 60 keV. Here, we conduct an analysis of possible grating configurations for this technique and present further geometrical arrangements not considered so far. An inverse interferometer geometry is investigated that offers significant advantages for grating fabrication and for the application of the method in computed tomography (CT) scanners. We derive and measure the interferometer's angular sensitivity for both the inverse and the conventional configuration as a function of the sample position. Thereby, we show that both arrangements are equally sensitive and that the highest sensitivity is obtained, when the investigated object is close to the interferometer's phase grating. We also discuss the question whether the sample should be placed in front of or behind the phase grating. For CT applications, we propose an inverse geometry with the sample position behind the phase grating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗