Search NASA⌕ Search

Engineering topics

Schwarz, S.

Publications and source records attributed to Schwarz, S..

At least 19 records

Precision Mass Measurement of the Proton Dripline Halo Candidate 22 Al

Here, we report the first mass measurement of the proton-halo candidate 22 Al performed with the low energy beam ion trap facility’s 9.4 T Penning trap mass spectrometer at facility for rare isotope beams. This measurement completes the mass information for the lightest remaining proton-dripline nucleus achievable with Penning traps. 22 Al has been the subject of recent interest regarding a possible halo structure from the observation of an exceptionally large isospin asymmetry [J. Lee et al ., Large isospin asymmetry in Si22/O22 Mirror Gamow-Teller transitions reveals the halo structure of 22 Al , Phys. Rev. Lett. 125, 192503 (2020).]. The measured mass excess value of ME=18 092.5⁢(3) keV, corresponding to an exceptionally small proton separation energy of 𝑆𝑝=100.4⁢(8) keV, is compatible with the suggested halo structure. Our result agrees well with predictions from 𝑠⁢𝑑-shell USD Hamiltonians. While USD Hamiltonians predict deformation in the 22 Al ground state with minimal 1⁢𝑠 1/2 occupation in the proton shell, a particle-plus-rotor model in the continuum suggests that a proton halo could form at large quadrupole deformation. These results emphasize the need for a charge radius measurement to conclusively determine the halo nature.

binding energy↗

First direct 7 Be electron-capture $\mathrm{Q}$-value measurement toward high-precision searches for neutrino physics beyond the Standard Model

Here, we report the first direct measurement of the nuclear electron-capture (EC) decay Q value of 7 Be → 7 Li via high-precision Penning trap mass spectrometry (PTMS). This was performed using the LEBIT Penning trap located at the National Superconducting Cyclotron Laboratory/Facility for Rare Isotope Beams (NSCL/FRIB) using the newly commissioned Batch-Mode Ion-Source (BMIS) to deliver the unstable 7 Be + samples. With a measured value of Q EC = 861.963(23) keV, this result is three times more precise than any previous determination of this quantity. This improved precision and accuracy of the 7 Be EC decay Q value is critical for ongoing experiments that measure the recoiling nucleus in this system as a signature to search for beyond the Standard Model (BSM) neutrino physics using 7 Be-doped superconducting sensors. This experiment has extended LEBIT capabilities, using the first low-energy beam delivered by BMIS at FRIB for PTMS, as well as measuring the lightest-mass isotopes so far with LEBIT.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass measurement of 27 P to constrain type-I x-ray burst models and validate the isobaric multiplet mass equation for the $A = 27, T = \frac{3}{2}$ isospin quartet

Background: Light curves are the primary observable of type-I x-ray bursts. Computational x-ray burst models must match simulations to observed light curves. Most of the error in simulated curves comes from uncertainties in rp process reaction rates, which can be reduced via precision mass measurements of neutron-deficient isotopes in the rp process path. Purpose: Perform a precise atomic mass measurement of 27 P. Use this new measurement to calculate rp process reaction rates and input these rates into an x-ray burst model to reduce simulated light curve uncertainty. Use the mass measurement of 27 P to validate the isobaric multiplet mass equation (IMME) for the A = 27 T = 3/2 isospin quartet which 27 P belongs to. Method: High-precision Penning trap mass spectrometry utilizing the time-of-flight ion cyclotron resonance technique was used to determine the atomic mass of 27 P. The MESA code (Modules for Experiments in Stellar Astrophysics) was then used to simulate x-ray bursts using a one-dimensional multizone model to produce updated light curves. Results: The mass excess of 27 P was measured to be –670.7(6) keV, a 14-fold precision increase over the mass reported in the 2020 Atomic Mass Evaluation (AME2020). The 26 Si(p, $γ$) 27 P– 27 P($γ$, p) 26 Si rate equilibrium has been determined to a higher precision based on the precision mass measurement of 27 P. x-ray burst light curves were produced with the MESA code using the new reaction rates. Changes in the mass of 27 P seem to have minimal effect on light curves, even in burster systems tailored to maximize impact. Conclusion: The mass of 27 P does not play a significant role in x-ray burst light curves. It is important to understand that more advanced models do not just provide more precise results, but often qualitatively different ones. This result brings us a step closer to being able to extract stellar parameters from individual x-ray burst observations. In addition, the IMME has been validated for the A = 27, T = 3/2 quartet. The normal quadratic form of the IMME using the latest data yields a reduced $χ$ 2 of 2.9. Finally, the cubic term required to generate an exact fit to the latest data matches theoretical attempts to predict this term.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gas stopping and reacceleration techniques at the Facility for Rare Isotope Beams (FRIB)

The Facility for Rare Isotope Beams (FRIB) at Michigan State University provides a wide range of beams and energies for science with fast, stopped and reaccelerated rare-isotope beams. FRIB was commissioned in 2022 with the science program beginning in May 2022. Here, the combination of fast beams followed by gas stopping of rare-isotope beams together with reacceleration is unique to FRIB. Stopping techniques and beam manipulation at very-low energies are important to slow down fast beams for use in either stopped-beam experimental devices, or subsequent injection in the reaccelerator for experiments at energies ranging from 0.3 MeV/u to 12 MeV/u, depending on the Q/A of the ion. Innovative stopped-beam techniques to optimize the stopping and extraction efficiencies across a wide range of atomic numbers, as well as to reduce contamination and increase extraction speed, were developed. Reacceleration of those beams involve cooling, bunching, charge breeding and acceleration by a state-of-the-art superconducting reaccelerator, ReA. In this contribution we present the latest results of various gas stoppers and techniques to eliminate contaminants after reacceleration by the ReA.

43 PARTICLE ACCELERATORS↗

The new Batch Mode Ion Source for stand-alone operation at the Facility for Rare Isotope Beams (FRIB)

Gas stoppers have been used for a long-standing successful science program at Michigan State University with stopped and rare-isotope beams produced by projectile fragmentation. The National Superconducting Cyclotron Laboratory’s Coupled Cyclotron Facility has recently transitioned into the Facility for Rare Isotope Beams (FRIB) laboratory to provide rare isotopes using a high-power superconducting linear accelerator and new production facilities. To allow the science program with stopped and reaccelerated beams to continue during the transition period, a stand-alone capability was added. The Batch Mode Ion Source (BMIS) was built and has been providing beams of long-lived and stable isotopes of a variety of elements for successful user experiments. Finally, the BMIS system is described and results from the production of various beams are presented.

47 OTHER INSTRUMENTATION↗

The cyclotron gas stopper at FRIB getting ready for operations

Linear gas stopping cells have been used for nearly two decades to slow down projectile fragments at the National Superconducting Cyclotron Laboratory, now the Facility for Rare Isotope Beams, for experiments with low-energy and reaccelerated beams. In order to efficiently stop and rapidly extract light to medium-mass fast ions, a cyclotron gas-stopper has been constructed. It uses a cyclotron-type magnet and a helium-gas filled stopping chamber to slow down the injected beam. RF ion guides transport the stopped ions to the center of the magnet and axially through the bore before acceleration to <60 keV. Following successful offline tests, the cyclotron stopper was moved to an experimental vault and connected to a new momentum–compression beam line. Beam transport to and into the cyclotron stopper was tested with stable beams. Finally, using 46 K fragments, the first successful stopping and extraction of a high-energy beam with the cyclotron stopper was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved nuclear physics near A = 61 refines urca neutrino luminosities in accreted neutron star crusts

We performed Penning trap mass measurements for 61 Zn at the National Superconducting Cyclotron Laboratory and NuShellX calculations of the 61 Zn and 62 Ga structure using the GXPF1A Hamiltonian to obtain improved estimates of the 61 Zn(p,γ) 62 Ga and 60 Cu(p,γ) 61 Zn reaction rates. Surveying astrophysical conditions for type-I x-ray bursts with the code mesa, implementing our improved reaction rates, and taking into account updated nuclear masses for 61 V and 61 Cr from the recent literature, we refine the neutrino luminosity from the important mass number A = 61 urca cooling source in accreted neutron-star crusts. Furthermore, this improves our understanding of the thermal barrier between deep heating in the crust and the shallow depths where extra heat is needed to explain x-ray superbursts, as well as the expected signature of crust urca neutrino emission in light curves of cooling transients

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Particle-in-cell techniques for the study of space charge effects in the Advanced Cryogenic Gas Stopper

The Facility for Rare Isotope Beams, FRIB, will significantly increase the rates and varieties of rare isotopes compared to those presently available at existing rare-isotope facilities. The production of stopped beams via the current generation of linear gas stopping devices available is not well matched to the beam intensities that will be available at FRIB. Many experiments that make use of reaccelerated beams, from the ReA facility, greatly benefit from having the highest-intensity, rare-isotope beams possible. Some experiments would also benefit greatly from stopped beams with improved purity. In this paper, the intensity bottlenecks of FRIB’s newest linear gas stopper are studied via experiment and simulation in support of a future detailed conceptual design of a next-generation linear gas stopper that can provide rare-isotope beams with rates of 10^8 pps, a factor of 50 higher than the current state-of-the-art system, with improved beam purity.

43 PARTICLE ACCELERATORS↗

First Penning trap mass measurement of 36 Ca

Background: Isobaric quintets provide the best test of the isobaric multiplet mass equation (IMME) and can uniquely identify higher order corrections suggestive of isospin symmetry breaking effects in the nuclear Hamilto nian. The Generalized IMME (GIMME) is a novel microscopic interaction theory that predicts an extension to the quadratic form of the IMME. Only the A = 20, 32 T = 2 quintets have the exotic T z = –2 member ground state mass determined to high-precision by Penning trap mass spectrometry. Purpose: To establish A = 36 as the third high-precision T = 2 isobaric quintet with the T z = –2 member ground state mass measured by Penning trap mass spectrometry and provide the first test of the predictive power of the GIMME. Method: Here, a radioactive beam of neutron-deficient 36 Ca was produced by projectile fragmentation at the National Superconducting Cyclotron Laboratory. The beam was thermalized and the mass of 36 Ca + and 36 Ca 2+ measured by the Time of Flight - Ion Cyclotron Resonance method in the LEBIT 9.4 T Penning trap. Results: We measure the mass excess of 36 Ca to be ME= –6483.6(56) keV, an improvement in precision by a factor of 6 over the literature value. The new datum is considered together with evaluated nuclear data on the A = 36, T = 2 quintet. We find agreement with the quadratic form of the IMME given by isospin symmetry, but only coarse qualitative agreement with predictions of the GIMME. Conclusion: A total of three isobaric quintets have their most exotic members measured by Penning trap mass spectrometry. The GIMME predictions in the T = 2 quintet appear to break down for A = 32 and greater.

20 ≤ A ≤ 38↗

High-precision mass measurements of the isomeric and ground states of 44 V: Improving constraints on the isobaric multiplet mass equation parameters of the A=44, 0 + quintet

Background: The quadratic isobaric multiplet mass equation (IMME) has been very successful at predicting the masses of isobaric analog states in the same multiplet, while its coefficients are known to follow specific trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] 44 V mass value results in an anomalous negative c coefficient for the IMME quadratic term; a consequence of large uncertainty and an unresolved isomeric state. The b and c coefficients can provide useful constraints for construction of the isospin-nonconserving Hamiltonians for the pf shell. In addition, the excitation energy of the 0 + , T = 2 level in 44 V is currently unknown. This state can be used to constrain the mass of the more exotic 44 Cr. Purpose: The aim of the experimental campaign was to perform high-precision mass measurements to resolve the difference between 44 V isomeric and ground states, to test the IMME using the new ground state mass value and to provide necessary ingredients for the future identification of the 0 + , T = 2 state in 44 V. Method: High-precision Penning trap mass spectrometry was performed at LEBIT, located at the National Superconducting Cyclotron Laboratory, to measure the cyclotron frequency ratios of [ 44g,m VO] + versus [ 32 SCO] + , a well-known reference mass, to extract both the isomeric and ground state masses of 44 V. Results: The mass excess of the ground and isomeric states in 44 V were measured to be -23 804.9(80) keV/c 2 and -23 537.0(55) keV/c 2 , respectively. This yielded a new proton separation energy of S p = 1 773(10) keV. Conclusion: The new values of the ground state and isomeric state masses of 44 V have been used to deduce the IMME b and c coefficients of the lowest 2 + and 6 + triplets in A = 44. The 2 + c coefficient is now verified with the IMME trend for lowest multiplets and is in good agreement with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between 44 V and 44 Sc, in line with isospin-symmetry for this multiplet. Finally, the new value of the proton separation energy determined, to an uncertainty of 10 keV, will be important for the determination of the 0 + , T = 2 state in 44 V and, consequently, for prediction of the mass excess of 44 Cr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass measurement of 51 Fe for the determination of the 51 Fe($p, γ$) 52 Co reaction rate

Background: The 51 Fe(p, γ) 52 Co reaction lies along the main rp-process path leading up to the 56 Ni waiting point. The uncertainty in the reaction Q value, which determines the equilibrium between the forward protoncapture and reverse photodisintegration 52 Co(γ,p) 51 Fe reaction, contributes to considerable uncertainty in the reaction rate in the temperature range of interest for Type I x-ray bursts and thus to an ≈10% uncertainty in burst ashes lighter than A = 56. Purpose: With a recent Penning trap mass measurement of 52 Co reducing the uncertainty on its mass to 6.6 keV [Nesterenko et al., J. Phys. G 44, 065103 (2017)], the dominant source of uncertainty in the reaction Q value is now the mass of 51 Fe, reported in the 2016 atomic mass evaluation to a precision of 9 keV [Wang et al., Chin.Phys. C 41, 030003 (2017)]. A new, high-precision Penning trap mass measurement of 51 Fe was performed to allow the determination of an improved precision Q value and thus new reaction rates. Method: 51 Fe was produced using projectile fragmentation at the Coupled Cyclotron Facility at the National Superconducting Cyclotron Laboratory, and separated using the A1900 fragment separator. The resulting secondary beam was then thermalized in the beam stopping area before a mass measurement was performed using the LEBIT 9.4T Penning trap mass spectrometer. Results: The new mass excess, ME = -40189.2(1.6) keV, is sixfold more precise than the current AME value, and 1.6σ less negative. This value was used to calculate a new proton separation energy for 52 Co of 1431(7) keV. New excitation levels were then calculated for 52 Co using the NUSHELLX code with the GXPF1A interaction, and a new reaction rate and burst ash composition was calculated. Conclusions:With a new measured Q value, the uncertainty on the 51 Fe(p, γ ) reaction rate is dominated by the poorly measured 52 Co level structure. Finally, reducing this uncertainty would allow a more precise rate calculation and a better determination of the mass abundances in the burst ashes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Precision Mass Measurement of Cu 56 and the Redirection of the r p -Process Flow

We report the mass measurement of 56 Cu, using the LEBIT 9.4 T Penning trap mass spectrometer at the National Superconducting Cyclotron Laboratory at Michigan State University. The mass of 56 Cu is critical for constraining the reaction rates of the 55 Ni(p,y), 56 Cu(p,y), 57 Zn(β + ) 57 Cu bypass around the 56 Ni waiting point. Previous recommended mass excess values have disagreed by several hundred keV. Our new value, ME = -38626.7(7.1) keV, is a factor of 30 more precise than the extrapolated value suggested in the 2012 atomic mass evaluation [Chin. Phys. C 36, 1603 (2012)], and more than a factor of 12 more precise than values calculated using local mass extrapolations, while agreeing with the newest 2016 atomic mass evaluation value [Chin. Phys. C 41, 030003 (2017)]. The new experimental average, using our new mass and the value from AME2016, is used to calculate the astrophysical 55 Ni(p,y) and 56 Cu(p,y) forward and reverse rates and perform reaction network calculations of the rp process. These show that the rp-process flow redirects around the 56 Ni waiting point through the 55 Ni(p,y) route, allowing it to proceed to higher masses more quickly and resulting in a reduction in ashes around this waiting point and an enhancement to higher mass ashes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of the direct double- β -decay Q value of Zr 96 and atomic masses of Zr 90 - 92 , 94 , 96 and Mo 92 , 94 - 98 , 100

Experimental searches for neutrinoless double-β decay offer one of the best opportunities to look for physics beyond the standard model. Detecting this decay would confirm the Majorana nature of the neutrino, and a measurement of its half-life can be used to determine the absolute neutrino mass scale. Important to both tasks is an accurate knowledge of the Q value of the double-β decay. The LEBIT Penning trap mass spectrometer was used for the first direct experimental determination of the ⁹⁶Zr double-β decay Q value: Q ββ =3355.85(15) keV. This value is nearly 7 keV larger than the 2012 Atomic Mass Evaluation [M. Wang et al., Chin. Phys. C 36, 1603 (2012)] value and one order of magnitude more precise. The 3-σ shift is primarily due to a more accurate measurement of the ⁹⁶Zr atomic mass: m(⁹⁶Zr)=95.90827735(17) u. Using the new Q value, the 2νββ-decay matrix element, |M 2ν |, is calculated. Improved determinations of the atomic masses of all other zirconium ( 90-92,94,96 Zr) and molybdenum ( 92,94-98,100 Mo) isotopes using both ¹²C₈ and ⁸⁷Rb as references are also reported.

Gulyuz, K.↗

A field programmable gate array-based time-resolved scaler for collinear laser spectroscopy with bunched radioactive potassium beams

A new data acquisition system including a Field Programmable Gate Array (FPGA) based time-resolved scaler was developed for laser-induced fluorescence and beam bunch coincidence measurements. The FPGA scaler was tested in a collinear laser-spectroscopy experiment on radioactive {sup 37}K at the BEam COoler and LAser spectroscopy (BECOLA) facility at the National Superconducting Cyclotron Laboratory at Michigan State University. A 1.29 μs bunch width from the buncher and a bunch repetition rate of 2.5 Hz led to a background suppression factor of 3.1 × 10{sup 5} in resonant photon detection measurements. The hyperfine structure of {sup 37}K and its isotope shift relative to the stable {sup 39}K were determined using 5 × 10{sup 4} s{sup −1} {sup 37}K ions injected into the BECOLA beam line. The obtained hyperfine coupling constants A({sup 2}S{sub 1/2}) = 120.3(1.4) MHz, A({sup 2}P{sub 1/2}) = 15.2(1.1) MHz, and A({sup 2}P{sub 3/2}) = 1.4(8) MHz, and the isotope shift δν{sup 39,} {sup 37} = −264(3) MHz are consistent with the previously determined values, where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗