Search NASASearch

Engineering topics

Scott, D. M.

Publications and source records attributed to Scott, D. M..

Characterization of the Crab Pulsar's Timing Noise

We present a power spectral analysis of the Crab pulsar's timing noise, mainly using radio measurements from Jodrell Bank taken over the period 1982-1989, an interval bounded by sparse data sampling and a large glitch. The power spectral analysis is complicated by nonuniform data sampling and the presence of a steep red power spectrum that can distort power spectra measurement by causing severe power 'leakage'. We develop a simple windowing method for computing red noise power spectra of uniformly sampled data sets and test it on Monte Carlo generated sample realizations of red power-law noise. We generalize time-domain methods of generating power-law red noise with even integer spectral indices to the case of noninteger spectral indices. The Jodrell Bank pulse phase residuals are dense and smooth enough that an interpolation onto a uniform time series is possible. A windowed power spectrum is computed revealing a periodic or nearly periodic component with a period of 568 +/- 10 days and a l/f(exp 3) power-law noise component in pulse phase with a noise strength S(sub infinity)=(1.24 +/- 0.067) x 10(exp 16) cycles(exp 2)/sec(exp 2) over the analysis frequency range f=0.003- 0.1 cycles/day. This result deviates from past analyses which characterized the pulse phase timing residuals as either l/f(sub 4) power-law noise or a quasiperiodic process. The analysis was checked using the Deeter polynomial method of power spectrum estimation that was developed for the case of nonuniform sampling, but has lower spectral resolution. The timing noise is consistent with a torque noise spectrum rising with analysis frequency as f implying blue torque noise, a result not predicted by current models of pulsar timing noise. If the periodic or nearly periodic component is due to a binary companion, we find a mass function f(M) = (6.8 +/- 2.4) x 10(exp -16) solar mass and a companion mass, M(sub c) is greater than or equal to 3.2 solar mass assuming a Crab pulsar mass of 1.4 solar mass.

Scott, D. M.

Timing Noise in SGR 1806-20

We have phase-connected a sequence of Rossi X-Ray Timing Explorer Proportional Counter Array observations of SGR 1806-20 covering 178 days. We find that a simple secular spin-down model does not adequately fit the data. The period derivative varies gradually during the observations between 8.1 x 10(exp -11) and 11.7 x 10(exp -11) s/s (at its highest, approximately 40% larger than the long-term trend), while the average burst rate as seen with the Burst and Transient Source Experiment drops throughout the time interval. The phase residuals give no compelling evidence for periodicity, but more closely resemble timing noise as seen in radio pulsars. The magnitude of the timing noise, however, is large relative to the noise level typically found in radio pulsars (Delta(sub 8) = 4.8; frequency derivative average power approximately 7 x 10(exp -20) sq cycles/cubic s). Combining these results with the noise levels measured for some anomalous X-ray pulsars, we find that all magnetar candidates have Delta(sub 8) values larger than those expected from a simple extrapolation of the correlation found in radio pulsars. We find that the timing noise in SGR 1806-20 is greater than or equal to the levels found in some accreting systems (e.g., Vela X-1, 4U 1538-52, and 4U 1626-67), but the spin-down of SGR 1806-20 has thus far maintained coherence over 6 yr. Alternatively, an orbital model with a period P(sub orb) = 733 days provides a statistically acceptable fit to the data. If the phase residuals are created by Doppler shifts from a gravitationally bound companion, then the allowed parameter space for the mass function (small) and orbital separation (large) rule out the possibility of accretion from the companion sufficient to power the persistent emission from the SGR.

Woods, P. M.

A Search for Short-Period Accreting Pulsars with BATSE

Accreting X-ray pulsar systems can be detected and monitored by the BATSE Pulsar Monitor at full sensitivity only above the Nyquist period of 2.048 s, since it uses the DISCLA data type. Systems with shorter periods than 2 s can be observed, but with a reduced sensitivity, since only the aliased power is measured. While persistent sources in the period range below that have been found by earlier spacecraft, transient systems may still be undiscovered, due to limited time coverage of the galactic plane with all-sky instruments. BATSE data with a time resolution of 31 ms (PSR single-sweep mode) has been collected for four energy channels spanning 20-50 keV , at scheduled times for particular detectors and detector combinations which view the galactic plane. The data spans Nov 1993 to present, with a typical exposure of 15000 s per day to approximately 1/8 of the plane. An accelerated FFT-based search is in progress on these data. Data are segmented into approximately 300 second intervals, barycentered for 3 possible source directions spaced by 30 degrees about the detector normal, with the time series accelerated for each of 15 steps, each spaced by 5 x 10(exp -5). To avoid loss of coherence due to system orbital velocities, FFTs are averaged over each 1/4 day interval separately. Results of this search are presented, including examples of detection of Her X-1, Cen X-3, and other pulsars.

Wilson, R. B.

GRO J2058+42 Observations with BATSE and RXTE

GRO J2058+422 is a 196 second pulsar discovered with BATSE during a giant outburst in 1995. It underwent a series of 9 weaker outbursts from 1995 to 1997 which alternated in intensity, with a 110 day cycle in the 20-50 keV band. These outbursts did not show the same, intensity variations in the 2-10 keV observations with the RXTE ASM. Additional outbursts after this series were observed with BATSE, using a more sensitive search method which accounts for excess aperiodic noise from Cygnus X-1, and with the RXTE PCA and ASM. A set of two outbursts, one "periastron" and one "apastron" outburst (assuming a 110 day orbital period) were observed with the RXTE PCA. Pulse shape differences were found between the two outbursts. Histories of pulse frequency, pulsed flux. and total flux are presented. Pulse profiles and spectra from PCA observations are also presented.

Wilson, Colleen A.

Discovery and Orbital Determination of the Transient X-Ray Pulsar GRO J1750-27

We report on the discovery and hard X-ray (20 - 70 keV) observations of the 4.45 s period transient X-ray pulsar GRO J1750-27 with the BATSE all-sky monitor on board CGRO. A relatively faint out- burst (less than 30 mcrab peak) lasting at least 60 days was observed during which the spin-up rate peaked at 38 pHz/s and was correlated with the pulsed intensity. An orbit with a period of 29.8 days was found. The large spin-up rate, spin period, and orbital period together suggest that accretion is occurring from a disk and that the outburst is a "giant" outburst typical of a Be/X-ray transient system. No optical counterpart has yet been reported.

Scott, D. M.

Observation of a Long-Term Spin-up Trend in 4U 1538-52

The high-mass X-ray pulsar 4U 153 8-52 has been continually monitored by the Burst and Transient Source Experiment (BATSE) on Compton Gamma-Ray Observatory. These observations permit the construction of long-term pulse frequency and intensity histories. The frequency history reveals that a reversal of the long-term trend in the accretion torque, from spinning down to spinning up, has occurred, probably in 1988. This is the first time a long-term change is known to have occurred for this source, The magnitude of the average absolute value of (dot-nu / nu) is approximately 10(exp -11)/s over an interval of approximately 5 year is similar during spin-down and spin-up. Shorter term pulse frequency variations of either sign are also observed. The power density spectrum of fluctuations in angular acceleration is consistent with white noise on timescales from 16 to 1600 days. It can be well fit with a power law with a power-law index of 0.10 plus or minus 0.21 and white noise strength of (7.6 +/- 1.6) x 10(exp -21) (Hz/s(exp 2)/Hz). These observations are also used to set 95% confidence level lower and upper limits on the rate of orbital period change, -3.9< dot-P orb /P orb <2. 1, in units of 10(exp -6) yr(exp -1).

Rubin, B. C.

Long-term variability in bright hard X-ray sources: 5+ years of BATSE data

The operation of the Compton Gamma Ray Observatory (CGRO)/burst and transient source experiment (BATSE) continues to provide data for inclusion into a data base for the analysis of long term variability in bright, hard X-ray sources. The all-sky capability of BATSE provides up to 30 flux measurements/day for each source. The long baseline and the various rising and setting occultation flux measurements allow searches for periodic and quasi-periodic signals with periods of between several hours to hundreds of days to be conducted. The preliminary results from an analysis of the hard X-ray variability in 24 of the brightest BATSE sources are presented. Power density spectra are computed for each source and profiles are presented of the hard X-ray orbital modulations in some X-ray binaries, together with amplitude modulations and variations in outburst durations and intensities in recurrent X-ray transients.

Robinson, C. R.

Torque Reversal and Spin-Down of the Accretion-Powered Pulsar 4U 1626-67

Over 5 yr of hard X-ray (20-60 keV) monitoring of the 7.66 s accretion-powered pulsar 4U 1626-67 with the Compton Gamma Ray Observatory/BATSE large-area detectors has revealed that the neutron star is now steadily spinning down, in marked contrast to the steady spin-up and spin-down torques differ by only 15% with the neutron star spin changing on a timescale |v/v| approximately equals 5000 yr in both states. The current spin-down rate is itself decreasing on a timescale |v/v| approximately equals 26 yr. The long-term timing history shows small-amplitude variations on a 4000 day timescale, which are probably due to variations in the mass transfer rate. The pulsed 20-60 keV emission from 4U 1626-67 is well-fitted by a power-law spectrum with photon index gamma = 4.9 and a typical pulsed intensity of 1.5 x 10(exp -10) ergs cm (exp -2)s(exp -1). The low count rates with BATSE prohibited us from constraining the reported 42 minute binary orbit, but we can rule out long-period orbits in the range 2 days < or = P(orb) < or = 900 days. We compare the long-term torque behavior of 4U 1626-67 to other disk-fed accreting pulsars and discuss the implications of our results for the various theories of magnetic accretion torques. The abrupt change in the sign of the torque is difficult to reconcile with the extremely smooth spin-down now observed. The strength of the torque noise in 4U 1626-67, approximately 10(exp -22) Hz(exp 2)s(exp -2) Hz(exp -1), is the smallest ever measured for an accreting X-ray pulsar, and it is comparable to the timing noise seen in young radio pulsars. We close by pointing out that the core temperature and external torque (the two parameters potentially relevant to internal sources of timing noise) of an accreting neutron star are also comparable to those of young radio pulsars.

Chakrabarty, Deepto L.

Discovery and Orbital Determination of the Transient X-Ray Pulsar GRO J1750-27

We report on the discovery and hard X-ray (20-70 keV) observations of the 4.45 second period transient X-ray pulsar GRO J1750-27 with the BATSE all-sky monitor on board CCRO. A relatively faint outburst (< 30 mCrab peak) lasting at least 60 days was observed during which the spin-up rate peaked at 38 pHz/sec and was correlated with the pulsed intensity. An orbit with a period of 29.8 days was found. The large spin-up rate, spin period and orbital period together suggest that accretion is occurring from a disk and that the outburst is a 'giant' outburst typical of a Be/X-ray transient system. No optical counterpart has been reported yet.

Scott, D. M.

The ultraviolet continuum and the fluorescent H2 lines in low-excitation Herbig-Haro objects

Long-exposure IUE observations are used here to determine the spatial distribution of the fluorescent H2 line emission in the low-excitation objects HH 43 and HH 47. In HH 43, the spatial distribution of the fluorescent H2 line emission has a width equal to or smaller than the width of the point-spread function of IUE, while both the short-wavelength UV continuum and the optical forbidden S II lines show distributions which are wider by more than a factor of two. In HH 47, the results are qualitatively analogous, but the differences between the fluorescent HH 23 emission distribution on the one hand, and the UV continuum and optical forbidden S II distribution on the other, are smaller. These distributions indicate that the appropriate conditions for the formation of fluorscent H2 lines are fulfilled only in rather narrow regions for these low-excitation objects. A continuous energy distribution in HH 43 and HH 47 is found which differs only slightly from that in the high-excitation objects HH 1 and HH 2.

Boehm, K. H.

Long-Term Observations of Her X-1 with BATSE

Pulsed emission from Her X-1 has been observed by BATSE during each Main High state throughout the CGRO (Compton Gamma-Ray Observatory) mission . This long observation set by a single instrument provides new information on long-term behavior of the Her X-1 system. The luminosity varies by more than a factor of 3 between different 35d cycles. Frequency and flux histories do not show a simple relationship between the source intensity and spin behavior, but do show that only spindown occurs when the source is in its lowest intensity state. Orbital analyses will be presented, including tests for consistency of the observed orbital epoch with the long-term ephemeris reported by (Deeter 1991). The intensity profile and onset times of cycles observed by both BATSE and the RXTE ASM (All Sky Monitor) will be compared. Behavior of the cycle start times versus source Main High peak intensity will be presented.

Wilson, R. B.

Oxygen impurity effects at metal/silicide interfaces - Formation of silicon oxide and suboxides in the Ni/Si system

The effect of implanted oxygen impurities on the Ni/Ni2Si interface is investigated using X-ray photoelectron spectroscopy, He-4(+) backscattering and O(d, alpha)-16 N-14 nuclear reactions. Oxygen dosages corresponding to concentrations of 1, 2, and 3 atomic percent were implanted into Ni films evaporated on Si substrates. The oxygen, nickel, and silicon core lines were monitored as a function of time during in situ growth of the Ni silicide to determine the chemical nature of the diffusion barrier which forms in the presence of oxygen impurities. Analysis of the Ni, Si, and O core levels demonstrates that the formation of SiO2 is responsible for the Ni diffusion barrier rather than Ni oxide or mixed oxides, such as Ni2SiO4. It is determined that 2.2 x 10 to the 16th O/qu cm is sufficient to prevent Ni diffusion under UHV annealing conditions.

Grunthaner, P. J.