Search NASA⌕ Search

Engineering topics

Scott, Steve

Publications and source records attributed to Scott, Steve.

Application of motional Stark effect in situ background correction to a superconducting tokamak

A polychrometer-type motional Stark effect (MSE) diagnostic technique, originally developed for the Alcator C-Mod tokamak, has been extended and applied to the Korea Superconducting Advanced Tokamak Research (KSTAR) device, the long-pulse superconducting tokamak, for the first time. It demonstrates a successful in situ subtraction of the polarized reflections off the vacuum vessel wall, sometimes up to half the total signal in some sightlines. To avoid the secondary neutral beam emission that may contaminate conventional beam-into-gas calibrations, a new approach, where the beam-into-gas measurements are made at various torus pressures with fixed vacuum fields, has been devised, which is possible with the stable superconducting coil systems of KSTAR. The validity of this new calibration scheme has been checked via plasma jog experiments. The experimental evidence of the polarized background light and the necessity of its correction in the MSE measurements made in KSTAR are presented as well.

47 OTHER INSTRUMENTATION↗

Disruption Prediction and Avoidance in High Beta Long Pulse KSTAR Plasmas

DoE Grant DE-SC0016409 (Disruption Prediction and Avoidance in High Beta Long Pulse KSTAR Plasmas) supported a collaboration among Columbia University, the Princeton Plasma Physics Laboratory (PPPL), and the Plasma Science and Fusion Center (PSFC) at MIT to conduct research on the KSTAR tokamak at the National Fusion Research Institute (NFRI) in Korea to improve predictive capability for disruptions in tokamaks. This initiative included upgrades to kinetic diagnostics at KSTAR whose measurements form the basis for the disruption prediction models. The major thrust of the PPPL and PSFC work was implementing a capability at KSTAR to allow partially-polarized background light seen by the KSTAR Motional Stark Effect (MSE) diagnostic to be compensated by ‘wavelength interpolation’ rather than the traditional ‘beam modulation’ technique. This objective was completed on time and on budget, and the MSE Background Polychromator is currently functioning at KSTAR. Primary responsibility for maintaining and operating the MSE-BP was transferred to Nova Photonics, Inc. in 2019.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Specification IEC TS 62989:2018 - Primary Optics for Concentrator Photovoltaic Systems

The first edition of the Technical Specification (TS) on Primary Optics for Concentrator Photovoltaic (CPV) Systems, IEC TS 62989:2018, has been published by the International Electrotechnical Commission (IEC), on March 8th, 2018. TS 62989 covers aspects related to the primary optics including: product identification, optical characteristics, mechanical characteristics, materials, (design) geometry, and visual appearance. This paper focuses on the key aspects of the norm, including optical performance, in order to promote the awareness and use of the standard. We describe the three methods intended to measure the key optical characteristics of the primary elements, i.e. focal spot size and optical efficiency, by using the encircled energy. The three methods are using different light sources, optical components and receiver sensors, but yielded very similar results in a round robin test. This justifies the continued use of all three methods. The use of a website (opticstests.pbworks.com) for documentation of discussions and references was novel to the standard development. The website proved to be useful for the introduction of new members of the group. The website helped to keep track of changes to the document as well as the required actions of the project team.

14 SOLAR ENERGY↗

Intrashot motional Stark effect calibration technique for lower hybrid current drive experiments

The spurious drift in pitch angle of order several degrees measured by the motional Stark effect (MSE) diagnostic in the Alcator C-Mod tokamak over the course of an experimental run day has precluded direct utilization of independent absolute calibrations. Recently, the underlying cause of the drift has been identified as thermal stress-induced birefringence in a set of in-vessel lenses. The shot-to-shot drift can be avoided by using MSE to measure only the change in pitch angle between a reference phase and a phase of physical interest within a single plasma discharge. This intrashot calibration technique has been applied to the lower hybrid current drive (LHCD) experiments and the measured current profiles qualitatively demonstrate several predictions of LHCD theory such as an inverse dependence of current drive efficiency on the parallel refractive index and the presence of off-axis current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intra-shot MSE Calibration Technique For LHCD Experiments

The spurious drift in pitch angle of order several degrees measured by the Motional Stark Effect (MSE) diagnostic in the Alcator C-Mod tokamak1 over the course of an experimental run day has precluded direct utilization of independent absolute calibrations. Recently, the underlying cause of the drift has been identified as thermal stress-induced birefringence in a set of in-vessel lenses. The shot-to-shot drift can be avoided by using MSE to measure only the change in pitch angle between a reference phase and a phase of physical interest within a single plasma discharge. This intra-shot calibration technique has been applied to the Lower Hybrid Current Drive (LHCD) experiments and the measured current profiles qualitatively demonstrate several predictions of LHCD theory such as an inverse dependence of current drive efficiency on the parallel refractive index and the presence of off-axis current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a New Optical System for Alcator C-Mod Motional Stark Effect Diagnostic

The motional Stark effect (MSE) diagnostic on Alcator C-Mod uses an in-vessel optical system (five lenses and three mirrors) to relay polarized light to an external polarimeter because port access limitations on Alcator C-Mod preclude a direct view of the diagnostic beam. The system experiences unacceptable, spurious drifts of order several degrees in measured pitch angle over the course of a run day. Recent experiments illuminated the MSE diagnostic with polarized light of fixed orientation as heat was applied to various optical elements. A large change in measured angle was observed as two particular lenses were heated, indicating that thermal-stress-induced birefringence is a likely cause of the spurious variability. Several new optical designs have been evaluated to eliminate the affected in-vessel lenses and to replace the focusing they provide with curved mirrors; however, ray tracing calculations imply that this method is not feasible. A new approach is under consideration that utilizes in situ calibrations with in-vessel reference polarized light sources. 2008 American Institute of Physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a new optical system for Alcator C-Mod motional Stark effect diagnostic

The motional Stark effect (MSE) diagnostic on Alcator C-Mod uses an in-vessel optical system (five lenses and three mirrors) to relay polarized light to an external polarimeter because port access limitations on Alcator C-Mod preclude a direct view of the diagnostic beam. The system experiences unacceptable, spurious drifts of order several degrees in measured pitch angle over the course of a run day. Recent experiments illuminated the MSE diagnostic with polarized light of fixed orientation as heat was applied to various optical elements. A large change in measured angle was observed as two particular lenses were heated, indicating that thermal-stress-induced birefringence is a likely cause of the spurious variability. Several new optical designs have been evaluated to eliminate the affected in-vessel lenses and to replace the focusing they provide with curved mirrors; however, ray tracing calculations imply that this method is not feasible. A new approach is under consideration that utilizes in situ calibrations with in-vessel reference polarized light sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-Orbit ACDS Performance of the Landsat 7 Spacecraft

Landsat 7 is part of NASA's Earth Science Enterprise (ESE). The ESE is committed to developing an understanding of the total Earth system, the effects of natural and human-induced changes on the global environment, and how natural processes affect humans and how humans affect them. The Landsat 7 satellite consists of the spacecraft bus which was provided under a NASA contract with Lockheed Martin Missiles and Space in Philadelphia, PA, and the Enhanced Thematic Mapper-Plus (ETM+) instrument, procured under a NASA contract with Raytheon Santa Barbara Remote Sensing, in Santa Barbara, CA. The Landsat 7 Attitude Control and Determination System (ACDS) provides many essential functions for the operation of the spacecraft bus and for ETM+. The ACDS maintains the required attitude and orbit at the degree of accuracy necessary for power generation, command and telemetry, thermal balance, image acquisition, Gimbaled X-Band Antenna (GXA) pointing and data for image post-processing. Descriptions of the Landsat 7 mission and the ACDS modes and requirements are presented. A brief summary of significant events of the on-orbit initialization and validation period are provided. Finally, the Landsat 7 product generation system is described and the impact that the ACDS performance has on the ground based image processing system is explored.

Sabelhaus, Phillip↗

Fresnel Lens

Fresnel lenses span the full range of sizes from lens a few micrometers in diameter to lens several meters in diameter. These lenses are utilized in various fields including optical communication, theatrical lighting, office equipment, video entertainment systems, solar concentrators, and scientific research instruments. These lenses function either as diffractive or refractive optical elements depending on the geometrical feature size of the lens. The basic functions of these lenses is described followed by an overview of fabrication methods. A summary of applications is then provided illustrating the rich variety of applications for which fresnel lenses may be designed to fulfill.

Watson, Michael D.↗