Search NASA⌕ Search

Engineering topics

Seaman, C. H.

Publications and source records attributed to Seaman, C. H..

Multiple Smaller Missions as a Direct Pathway to Mars Sample Return

Recent discoveries by the Mars Exploration Rovers, Mars Express, Mars Odyssey, and Mars Reconnaissance Orbiter spacecraft include multiple, tantalizing astrobiological targets representing both past and present environments on Mars. The most desirable path to Mars Sample Return (MSR) would be to collect and return samples from that site which provides the clearest examples of the variety of rock types considered a high priority for sample return (pristine igneous, sedimentary, and hydrothermal). Here we propose an MSR architecture in which the next steps (potentially launched in 2018) would entail a series of smaller missions, including caching, to multiple landing sites to verify the presence of high priority sample return targets through in situ analyses. This alternative architecture to one flagship-class sample caching mission to a single site would preserve a direct path to MSR as stipulated by the Planetary Decadal Survey, while permitting investigation of diverse deposit types and providing comparison of the site of returned samples to other aqueous environments on early Mars

Niles, P. B.↗

Altering Flashlamp Output for Realistic Solar Simulation

Commercial glass optical filter corrects spectrum of xenon flashtubes used to test photovoltaic solar cells. Filter withstands thousands of flashes without perceptible alteration of passband characteristics. With filter, calibration errors reduced to less than 1 percent.

Mueller, R. L.↗

Quasi drag free gradiometry

Gradiometers are instruments for measuring the gradient of the gravity vector. However, these devices are in varying degrees contaminated by gravity itself or by acceleration. To a large extent these problems are avoidable in orbit, and dramatic improvements in operating accuracy are envisioned. The considered improvements could lead to the possibility of detailed global gravity surveys of the earth, or other planets. An obstacle in the path toward the conduction of such surveys is related to the impossibility to demonstrate an instrument's potential orbital performance in the laboratory. A promising approach for orbital testing is possibly a procedure in which the Shuttle is operated as a drag free satellite. This procedure involves floating the gradiometer in the Shuttle bay. However, certain problems arise in connection with such a procedure. The present investigation is concerned with the possibility that the Shuttle's motion problems can be avoided through the use of a quasi-drag-free magnetic suspension.

Seaman, C. H.↗

Results of the 1981 NASA/JPL balloon flight solar cell calibration program

The calibration of the direct conversion of solar energy through use of solar cells at high altitudes by balloon flight is reported. Twenty seven modules were carried to an altitude of 35.4 kilometers. Silicon cells are stable for long periods of time and can be used as standards. It is demonstrated that the cell mounting cavity may be either black or white with equal validity in setting solar simulators. The calibrated cells can be used as reference standards in simulator testing of cells and arrays.

Seaman, C. H.↗

Calibration of solar cells by the reference cell method - The spectral mismatch problem

The calibration of solar cells by means of solar simulators and calibrated reference cells has always been faced with the problem of errors due to source spectral irradiance mismatch and cell spectral response mismatch. A general expression is derived in this paper to enable calculation of mismatch error. The information required to make this calculation is the relative spectra responses of the test and reference cells, and the relative spectral irradiance of the simulator (over the spectral range defined by cell response). The spectral irradiance of the solar standard is assumed given. Experimental results are presented.

Seaman, C. H.↗

Low-cost solar array project: Four absolute cavity radiometer (pyrheliometer) intercomparisons at New River, Arizona: Radiometer standards

Four detailed intercomparisons were made for a number of models of cavity-type self-calibrating radiometers (pyrheliometers). Each intercomparison consisted of simultaneous readings of pyrheliometers at 30-second intervals in runs of 10 minutes, with at least 15 runs per intercomparison. Twenty-seven instruments were in at least one intercomparison, and five were in all four. Summarized results and all raw data are provided from the intercomparisons.

Estey, R. S.↗

Results of the 1980 NASA/JPL balloon flight solar cell calibration program

Thirty-eight modules were carried to an altitude of about 36 kilometers. In addition to the cell calibration program, an experiment to evaluate the calibration error versus altitude was performed. The calibrated cells can be used as reference standards in simulator testing of cells and arrays.

Seaman, C. H.↗

The correction for spectral mismatch effects on the calibration of a solar cell when using a solar simulator

A general expression was derived to enable calculation of the calibration error. The information required includes the relative spectral response of the reference cell, the relative spectral response of the cell under test, and the relative spectral irradiance of the simulator (over the spectral range defined by cell response). The spectral irradiance of the solar AMX is assumed to be known.

Seaman, C. H.↗

Economical ultraviolet radiometer

Inexpensive, cosine-corrected radiometer measures ultraviolet radiation. In field use, instrument tests materials for effects of ultraviolet exposure and studies solar-cell degradation. It consists of cup-shaped diaphragm and diffusing dome for corrected response, two filters that select wavelength range, and silicon solar cell. Filters control response within passband of 300 to 400 nm.

Seaman, C. H.↗

Simulator spectral characterization using balloon calibrated solar cells with narrow band pass filters

The development and implementation of an instrument for spectral measurement of solar simulators for testing solar cell characteristics is reported. The device was constructed for detecting changes in solar simulator behavior and for comparing simulator spectral irradiance to solar AM0 output. It consists of a standard solar cell equipped with a band pass filter narrow enough so that, when flown on a balloon to sufficient altitude along with sufficient numbers of cells, each equipped with filters of different bandpass ratings, the entire spectral response of the standard cell can be determined. Measured short circuit currents from the balloon flights thus produce cell devices which, when exposed to solar simulator light, have a current which does or does not respond as observed under actual AM0 conditions. Improvements of the filtered cells in terms of finer bandpass filter tuning and measurement of temperature coefficients are indicated.

Goodelle, G. S.↗

Instrument remotely measures wind velocities

Doppler-shift spectrometer makes remote satellite measurements of atmospheric wind velocity and temperature at specified altitudes. As in correlation spectrometer, spectrum of gas in reference cell and spectrum of same gas in atmosphere are correlated both in emission and absorption.

Margolis, J. S.↗

Method and apparatus for Doppler frequency modulation of radiation

A method and apparatus are described for frequency modulating radiation, such as from a laser, for optoacoustic detectors, interferometers, heterodyne spectrometers, and similar devices. Two oppositely reciprocating cats-eye retroreflectors are used to Doppler modulate the radiation. By reciprocally moving both retroreflectors, the center of mass is maintained constant to permit smooth operation at many Hertz. By slightly offsetting the axis of one retroreflector relative to the other, multiple passes of a light beam may be achieved for greater Doppler shifts with the same reciprocating motion of the retroreflectors.

Margolis, J. S.↗

The spectral irradiance of some solar simulators and its effect on cell measurements

Moderate resolution spectral irradiance measurements in the range 300 nm to 1100 nm have been made of eight radiant sources which are currently being used as solar simulators. Spectral irradiance data are presented in graphical form. To demonstrate the interplay of source spectral distribution and cell spectral response, measurements of short circuit current of five cells of differing response characteristics have been made with these sources. These results are presented in tabular and graphical form.

Seaman, C. H.↗

Results of the 1978 NASA/JPL balloon flight solar cell calibration program

The 1978 scheduled solar cell calibration balloon flight was successfully completed. Thirty six modules were carried to an altitude of above 36 kilometers. Recovery of telemetry and flight packages was without incident. These calibrated standard cells are used as reference standards in simulator testing of cells and arrays with similar spectral response characteristics. The factors affecting the spectral transmission of the atmosphere at various altitudes are summarized.

Seaman, C. H.↗

Mechanisms of photon-induced changes in silicon solar cell parameters

Reversible changes in solar cell performance were induced by AM1 illumination and evaluated by measuring short-circuit current, weak light spectral response, and minority carrier diffusion length. In n(+)p cells the change manifests itself as a reduced short-circuit current, a loss of the red response, and a reduction in minority carrier diffusion length. In p(+)n cells there are two-photon induced effects: (1) enhancement of the blue spectral response, presumably occurring in the p(+) layer and (2) degradation in open-circuit voltage at low light levels due to increased leakage occurring only after the junction edge is exposed to bright light. Most of these photon effects are attributed to defects in the silicon.

Cheng, L. J.↗