Search NASA⌕ Search

Engineering topics

Searle, Matthew

Publications and source records attributed to Searle, Matthew.

At least 37 records · Page 2

Performance of Additively Manufactured Internally Cooled Airfoils for Small Industrial Gas Turbines

The goal of this effort is to screen several internally cooled airfoil designs that could be fabricated when additive manufacturing becomes a viable alternative for industrial gas turbine applications. The objectives of the current paper are as follows: 1) Describe two advanced additively manufactured cooling schemes, 2) Describe the analytical tools and results that guided the design. 3) Identify key additive manufacturing issues and steps taken to mitigate these issues. 4) Compare experimentally measured cooling technology curves to 1-D cooling models, and 5) Compare the cooling performance of three different internally cooled airfoils using experimentally measured cooling technology curves.

Straub, Douglas↗

Measurement of Convective Heat Transfer Coefficients with Supercritical CO2 in Novel Additively Manufactured Helically Patterned Pin Fin Tubes Using the Wilson Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO2 flowing in pin-fin patterned pipes in the Heat Exchange and Experimental Testing (HEET) facility at the US DoE’s National Energy Technology Laboratory (NETL) in Morgantown, WV. The measurement procedures in the HEET rig were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over typical Reynolds number range in sCO2, the measured Nu and friction factors were within 7% of classical correlations for smooth tube flow.The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section. Pin length to diameter aspect ratios were 1.33 and 2, while the pin diameter to tube diameter ratio was 0.188 and 0.125. Tests were performed for ReD varying from 6.9×104 to 2.2×105 and at conditions equivalent to the low pressure outlet (8.69 MPa, 361 K) of the low temperature recuperator (LTR) in an indirect sCO2 power cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients.For the better performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.188), the local heat transfer coefficient increased by 112% relative to the Dittus-Boelter correlation at the LTR low pressure outlet. This corresponded to a 282% increase in the product of the heat transfer coefficient and the surface area. Large pressure drops across the test articles were observed.

Searle, Matthew↗

The Effect of Working Fluid Composition on Heat Transfer in a Direct Supercritical CO2 Power Cycle Recuperator

For pure CO2, the experimental measurements of the heat transfer coefficient in this paper agreed to within 5% of the classical Dittus-Boelter correlation. When nitrogen was added to the CO2 at concentrations from 0–28% nitrogen, these experiments found that the measured Nusselt numbers decreased by 20% below the Dittus-Boelter correlation evaluated with thermophysical properties for the N2/CO2 gas mixture. In general, the McAdams correlation evaluated with mixture properties predicted the friction factor within ±10%.

Searle, Matthew↗

Characterizing Heat Transfer in sCO 2 Cycle Coolers Utilizing the Wilson Plot Technique

Effective design of coolers can decrease the capital expense of supercritical carbon dioxide (sCO 2 ) power plants. Improved datasets reporting heat transfer from the CO 2 in the cycle cooler allow design engineers to calculate the required length of heat exchanger streams more accurately, thus reducing cooler material and heat exchanger cost. This study considered a shell-and-tube heat exchanger with non-condensing CO 2 on the tube side and water flow on the shell side. The average Nusselt number on the tube side was measured employing the Wilson plot technique for a flow at a Reynolds number, Re, equal to 1×10 5 and for a heat flux to mass flux ratio, Q"/G, ranging from 50 to 350 J/kg. The results indicate that the Nusselt number, Nu, increases as the CO 2 pressure decreases towards the critical point. The results also indicate that Nu increases to maximum at Q"/G = 215 J/kg and then decreases with further increases in Q"/G. The difference in Nu measured between the horizontal and vertical heat exchanger with downward flowing CO 2 is less than the experimental error.

20 FOSSIL-FUELED POWER PLANTS↗

Surface Roughness Effects on Heat Transfer in Additively Manufactured sCO 2 Cycle Heat Exchangers

An experimental study was performed to consider the impact of surface roughness on heat transfer and pressure drop to supercritical carbon dioxide (sCO 2 ) in additively manufactured channels. All tests were performed in the Heat Exchange and Experimental Testing (HEET) rig at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia. Four test articles were considered. The first was a hydrodynamically smooth, drawn tube. The other three were additively manufactured channels with square and rectangular cross sections, which were characterized by sand-grain roughness to hydraulic diameter ratios spanning 0.0029 to 0.0073. Friction factors were determined by measuring the tube mass flow rate and pressure drop. The tube side heat transfer coefficient was measured using the Wilson plot technique. It was found that the friction factor results were 8% greater than the Colebrook correlation. Greater deviation was observed between the heat transfer results and the correlations. The Gnielinski correlation overpredicted the experimental points by nominally 30% and the Norris correlation overpredicting the experimental points by nominally 25%. A thermal performance factor was formed from the friction factor augmentation and Nusselt number augmentation results. These results indicated a 10% improvement in heat duty for a heat exchanger constructed utilizing a tube with ϵ/D_h =0.0073 relative to a heat exchanger utilizing a smooth, conventional tube.

36 MATERIALS SCIENCE↗

Baseline Airfoil Cooling Designs For 5-10MW Gas Turbines

This paper describes conventional cooling technologies that have been identified after a thorough review of public literature as a baseline for more detailed analysis and future testing. This effort is unique because the cooling features (i.e., leading edge, mid-chord, and trailing edge) are integrated together within an airfoil of realistic scale. The engineering models that have been developed to characterize the cooling performance for these baseline configurations will be described. It is believed that the cooling designs described in this paper are representative of gas turbines in the 5-10 MWe size range, but not identical to any commercial product. The present effort to establish a state-of-the-art cooling scheme is a first, and necessary, step in an on-going project to identify and test more advanced cooling concepts for CHP systems that are enabled by additive manufacturing.

Straub, Douglas↗

Baseline Airfoil Cooling Designs For 5-10MW Gas Turbines - Conference Paper

This paper describes conventional cooling technologies that have been identified after a thorough review of public literature as a baseline for more detailed analysis and future testing. This effort is unique because the cooling features (i.e., leading edge, mid-chord, and trailing edge) are integrated together within an airfoil of realistic scale. The engineering models that have been developed to characterize the cooling performance for these baseline configurations will be described. It is believed that the cooling designs described in this paper are representative of gas turbines in the 5-10 MWe size range, but not identical to any commercial product. The present effort to establish a state-of-the-art cooling scheme is a first, and necessary, step in an on-going project to identify and test more advanced cooling concepts for CHP systems that are enabled by additive manufacturing.

Straub, Douglas↗

Data set for Conventional Rib Turbulators for SCO2 Turbine Internal Cooling

This data set accompanies NETL Internal Report DOE/NETL-2021/2758. M. Searle, D. Straub, and J. Black, “Conventional Rib Turbulators For SCO2 Turbine Internal Cooling,” National Energy Technology Laboratory, Morgantown, June 28, 2021. The "Configuration" tab details the test configuration geometry and nominal set points. The "Exp point data" tab reports the thermal performance at the midpoint of the Wilson plot. The "Wilson plot data" tab are all Wilson resistance plots reported in the present work.

42 ENGINEERING↗

Conventional Rib Turbulators For SCO 2 Turbine Internal Cooling (Report)

This report documents experimental work in the NETL Heat Exchange and Experimental Testing (HEET) rig. The heat transfer performance of additively manufactured internal cooling features in supercritical CO 2 were characterized. It was demonstrated that the thermal performance factor of conventional angled rib turbulators remains independent of Reynolds number up to 3.1 x 10 5 indicating that these features may be employed to enhance heat transfer in sCO 2 turbine blades and vanes. This augmentation of heat transfer in the internal cooling passages decreases the required turbine coolant and improves the power cycle efficiency.

20 FOSSIL-FUELED POWER PLANTS↗

Heat Transfer Coefficients of Additively Manufactured Tubes with Internal Pin Fins for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in additively manufactured tubes with internal pin fins at the US DOE’s National Energy Technology Laboratory in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over Reynolds numbers (ReD) ranging from 5 × 10 4 to 2.5 × 10 5 , measured Nu was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow. The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section and were printed at a 30⁰ angle relative to the inner wall (to meet AM constraints). The pin arrangement was helical to promote enhanced heat transfer due to swirl flow. Pin length to diameter aspect ratio was 1.33, 2, and 8, while the pin diameter to tube diameter ratio was 0.188, 0.125, and 0.063. Tests were performed for ReD varying from 6.9 × 10 4 to 2.2 × 10 5 and at conditions equivalent to the low pressure (LP) outlet (8.69 MPa, 361 K) and the high pressure (HP) inlet (20.7 MPa, 350 K) of the low temperature recuperator (LTR) in an indirect sCO 2 cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients. For the best performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.19), the local heat transfer coefficient increased by 136% relative to the Dittus-Boelter correlation at the LTR low pressure outlet and 194% at the LTR high pressure inlet. These correspond to a 282% and a 271% increase in the product of the heat transfer coefficient and surface area (adjusted for fin efficiency) product, respectively. Large pressure drops across the test articles were observed. For Tube Design A, the average friction factor, across the range of ReD considered, was significantly larger than the McAdams correlation at both the LTR LP outlet and the LTR HP inlet. A thermal performance factor was utilized to express the ratio of material required to build a finned heat exchanger relative to a finless heat exchanger with the same heat duty and pumping power. Tube Design A was estimated to decrease the required heat exchanger material by 13%.

Searle, Matthew↗