Blind to Chemistry: Molecular Contaminant Films We Could Be Missing During Visual Inspections and the Potential Impact to System Performance

Throughout the assembly, integration and test process, molecular contamination levels of space mission hardware are monitored to meet system performance requirements. Qualitatively, reflective surfaces and witness mirrors are continuously inspected for the visible presence of molecular contaminant films. Quantitatively, periodic reflectance measurements of witness mirrors indicate changes of mirror reflectivity over time due to the accumulation of molecular contaminant films. However, both methods only consider the presence of a contaminant film and not the molecular composition. Additionally, there is a risk that hardware may appear to be “visibly clean” even with a molecular contaminant film present on critical surfaces. To address these issues, experiments were performed to quantify the maximum molecular contaminant film that could be missed in visual inspections on witness mirrors with five different contaminants present. The corresponding changes in mirror reflectivity were modeled using the program STACK to determine the impact to space mission hardware performance. The results of this study not only show the criticality in considering the chemical make-up of molecular contaminant films on system performance, but also the need to recognize and understand the limitations of traditional visual inspection techniques on detecting molecular contaminant films.

Seasly, Elaine↗

Analysis of Observed Contamination Through SAGE III's First Year on Orbit

SAGE III is a payload on the International Space Station that conducts measurements of ozone and other atmospheric constituents through the use of a moderate resolution spectrometer with an operating wavelength range of 290 nm to 1550 nm. Because of the optically sensitive nature of the payload, a suite of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) were included to monitor the operating environment. During the rst year of operation, the SAGE III TQCMs were instrumental in detecting several periods of higher contamination and localizing their sources. A clear window made from quartz crystal covers the instrument assembly's aperture. Under nominal operating conditions, this window is only open during science gathering activities. However, if the rates of contamination accumulation are detected to be above the background rate, the window will be kept closed during science gathering to protect the optically sensitive instrument mirror. An analysis of the signal transmissions through the window for the wavelengths of 290 nm to 1550 nm has been conducted to determine any possible degradation of the window and potential in uence on science data collected to date, and established a baseline for future analysis.

Thompson, Michael P.↗

Preventing Premature Death in the M&S Lifecycle: Lessons Learned from Resurrection and Modernization of a Space System Contamination Model

Models and simulations (M&S) are often developed to meet specific needs and unique requirements for a particular situation. Once the M&S is implemented for a specific case and questions are answered, the M&S may go dormant until a similar need arises again at a later time, perhaps months to years later. Possible modification of the M&S may be required, and issues may arise if the M&S is not well documented, captured, or available. This can severely limit the useful life of the M&S and hinder future development or enhancements. This situation occurred with an M&S tool that had been developed to determine the impact to space system performance due to the presence of molecular contaminant films accumulating on key spacecraft surfaces. The challenges and issues encountered when resurrecting, executing, and modernizing the tool will be presented as a case study. To stay ahead of tomorrow’s challenges, resources to create M&S tools must be utilized efficiently. Lessons learned from this case study will aid M&S developers and users in planning for proper maintenance, transfer, and capture of key M&S tools and knowledge to avoid increased cost, increased development time, and wasted resources for projects relying on M&S.

Seasly, Elaine↗

Exploring Surface Analysis Techniques for the Detection of Molecular Contaminants on Spacecraft

Molecular contamination is a known area of concern for spacecraft. To mitigate this risk, projects involving space flight hardware set requirements in a contamination control plan that establishes an allocation budget for the exposure of non-volatile residues (NVR) onto critical surfaces. The purpose of this work will focus on non-contact surface analysis and in situ monitoring to mitigate molecular contamination on space flight hardware. By using Scanning Electron Microscopy and Energy Dispersive Spectroscopy (SEM-EDS) with Raman Spectroscopy, an unlikely contaminant was identified on space flight hardware. Using traditional and surface analysis methods provided the broader view of the contamination sources allowing for best fit solutions to prevent any future exposure.

Rutherford, Gugu N.↗

Evaluation of Contamination Inspection and Analysis Methods through Modeling System Performance

Contamination is usually identified as a risk on the risk register for sensitive space systems hardware. Despite detailed, time-consuming, and costly contamination control efforts during assembly, integration, and test of space systems, contaminants are still found during visual inspections of hardware. Improved methods are needed to gather information during systems integration to catch potential contamination issues earlier and manage contamination risks better. This research explores evaluation of contamination inspection and analysis methods to determine optical system sensitivity to minimum detectable molecular contamination levels based on IEST-STD-CC1246E non-volatile residue (NVR) cleanliness levels. Potential future degradation of the system is modeled given chosen modules representative of optical elements in an optical system, minimum detectable molecular contamination levels for a chosen inspection and analysis method, and determining the effect of contamination on the system. By modeling system performance based on when molecular contamination is detected during systems integration and at what cleanliness level, the decision maker can perform trades amongst different inspection and analysis methods and determine if a planned method is adequate to meet system requirements and manage contamination risk.

Seasly, Elaine↗

Modular Open System Architecture for Reducing Contamination Risk in the Space and Missile Defense Supply Chain

To combat contamination of physical assets and provide reliable data to decision makers in the space and missile defense community, a modular open system architecture for creation of contamination models and standards is proposed. Predictive tools for quantifying the effects of contamination can be calibrated from NASA data of long-term orbiting assets. This data can then be extrapolated to missile defense predictive models. By utilizing a modular open system architecture, sensitive data can be de-coupled and protected while benefitting from open source data of calibrated models. This system architecture will include modules that will allow the designer to trade the effects of baseline performance against the lifecycle degradation due to contamination while modeling the lifecycle costs of alternative designs. In this way, each member of the supply chain becomes an informed and active participant in managing contamination risk early in the system lifecycle.