Search NASA⌕ Search

Engineering topics

Sedki, Mohammed

Publications and source records attributed to Sedki, Mohammed.

Electrochemically decorated gold nanoparticles on CVD graphene ChemFET sensor for the highly sensitive detection of As(III)

Here, in this paper, we report a novel reusable receptor-free chemically sensitive field-effect transistor (ChemFET) sensor for the sensitive detection of As(III) using electrochemical doping of Au nanoparticles (AuNPs)-chemical vapour deposition (CVD) graphene (Gr) sensing film (AuNPs-Gr). The sensor consists of a single-gap gold electrode and a single layer of CVD graphene as a conducting/sensing channel decorated with a thin layer of electrochemically deposited AuNPs to catalyze the electroreduction of As(III) ions onto the sensing channel. A new detection strategy was proposed by measuring the resistance change rate of the AuNPs-Gr sensing channel modified between the source electrode and drain electrode, wherein the resistance change was caused by the electrochemical doping of As(0). The results indicated that the electrochemical doping of As(0) onto the sensing channel led to an increase in resistance through the doping interaction among As(0), AuNPs and graphene, enabling the proposed sensor to have an extraordinary detection performance with a high sensitivity. Moreover, the proposed sensor can be recycled by removing the As(0) deposited on the sensing film with the aid of a simple electrochemical oxidization process. Additionally, the mechanism of the sensing strategy based on the electrochemical n-doping of As(0) into the AuNPs-Gr sensing film was investigated using a top liquid gate electrode. The As(III) concentration detected by the AuNPs-Gr ChemFET sensor was as low as 0.001 μg/L, demonstrating that such sensors with a compatible sensing strategy can be used to detect As(III) with high sensitivity, easy fabrication, fast response and can be recycled.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemiresistor sensor based on ion-imprinted polymer (IIP)-functionalized rGO for Cd(II) ions in water

This study reports the design and development of a novel chemiresistor (CR) sensor using ion imprinted polymer (IIP)-functionalized reduced graphene oxide (rGO) [IIP/rGO-CR] for cadmium ions (Cd(II)) determination in water. The sensor consisted of a CR transducer made of rGO channel bridging source and drain electrodes prepared by self-assembly and thermal reduction of graphene oxide (GO) on Au interdigitated electrodes chip fabricated on Si/SiO 2 substrate. The IIP was then grafted on rGO using surface-initiated reversible addition-fragmentation chain transfer (RAFT) polymerization with polyethylenimine (PEI) and methylacrylic acid (MAA) as dual functional monomers and Cd(II) ions as template through UV light-initiated copolymerization. The IIP functionalized on rGO acted as an effective recognition element that modulated the resistance of rGO-CR upon binding of Cd(II), enabling Cd(II) detection at ppb level in aqueous solutions. The prepared IIP/rGO-CR sensor worked effectively in the linear range of 2~200ppb and achieved a limit of detection (LOD) of 0.83 ppb, which is lower than the World Health Organization guidelines of 3ppb for drinking water quality. The developed sensor of IIP/rGO-CR showed a high selectivity against a variety of trace and heavy metal ions found in water and good stability for up to 60 days when stored at room temperature for Cd(II) determination in water. Further, the sensor was successfully applied to analyzing Cd(II) spiked in tap, lake and river waters with a 94.5%–113.5% recovery, demonstrating a high degree of accuracy even in complex water samples. Finally, our results illustrated that the CR sensor of IIP functionalized rGO provides a potential platform for sensitive, robust and low-cost environmental analysis of Cd(II) in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linker-Free Magnetite-Decorated Gold Nanoparticles (Fe3O4-Au): Synthesis, Characterization, and Application for Electrochemical Detection of Arsenic (III)

Linker-free magnetite nanoparticles (Fe3O4NPs)-decorated gold nanoparticles (AuNPs) were grown using a new protocol that can be used as a new platform for synthesis of other intact metal–metal oxide nanocomposites without the need for linkers. This minimizes the distance between the metal and metal oxide nanoparticles and ensures the optimum combined effects between the two material interfaces. X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy confirmed the successful synthesis of the Fe3O4-Au nanocomposite, without any change in the magnetite phase. Characterization, using transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy, revealed the composite to consist of AuNPs of 70 ± 10 nm diameter decorated with tiny 10 ± 3 nm diameter Fe3O4NPs in Au:Fe mass ratio of 5:1. The prepared Fe3O4-Au nanocomposite was embedded in ionic liquid (IL) and applied for the modification of glassy carbon electrode (GCE) for the electrochemical detection of As(III) in water. By combining the excellent catalytic properties of the AuNPs with the high adsorption capacity of the tiny Fe3O4NPs towards As(III), as well as the good conductivity of IL, the Fe3O4-Au-IL nanocomposite showed excellent performance in the square wave anodic stripping voltammetry detection of As(III). Under the optimized conditions, a linear range of 1 to 100 μg/L was achieved with a detection limit of 0.22 μg/L (S/N = 3), and no interference from 100-fold higher concentrations of a wide variety of cations and anions found in water. A very low residual standard deviation of 1.16% confirmed the high precision/reproducibility of As(III) analysis and the reliability of the Fe3O4-Au-IL sensing interface. Finally, this proposed sensing interface was successfully applied to analyzing synthetic river and wastewater samples with a 95–101% recovery, demonstrating excellent accuracy, even in complex synthetic river and wastewater samples containing high concentrations of humic acid without any sample pretreatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nano-FET-enabled biosensors: Materials perspective and recent advances in North America

Field-effect transistor (FET) is a very promising platform for biosensor applications due to its magnificent properties, including label-free detection, high sensitivity, fast response, real-time measurement capability, low running power, and the feasibility to miniaturize to a portable device. 1D (e.g. carbon nanotubes, Si nanowires, conductive polymer nanowires, 1D metal oxides, and others) and 2D (e.g. graphene materials, transition metal dichalcogenides, black phosphorus, and 2D metal oxides) materials, with their unique structural and electronic properties that are unavailable in bulk materials, have helped improve the sensitivity of FET biosensors and enabled detection down to single molecule. In this article, we give insights into the rapidly evolving field of 1D and 2D materials-based FET biosensors, with an emphasis on structure and electronic properties, synthesis, and biofunctionalization approaches of these nanomaterials. In addition, the progress in the 1D/2D-FET biosensors in North America, in the last decade, is summarized in tables. Moreover, challenges and future perspectives of 1D/2D-FET biosensors are covered.

1D materials↗

Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water

In this paper, bismuth subcarbonate (BiO)2CO3-reduced graphene oxide nanocomposite incorporated in Nafion matrix ((BiO)2CO3-rGO-Nafion) was synthesized and further applied, for the first time, in the sensitive detection of Pb(II) and Cd(II) by square-wave anodic stripping voltammetry (SWASV). The as-synthesized nanocomposites were characterized by energy-dispersive spectroscopy (EDS), Raman spectroscopy, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). (BiO)2CO3 composite plays a key role in the improvement of the detection sensitivity, which can form multicomponent alloy with cadmium and lead. Additionally, the unique structure of rGO can enlarge the surface area and provide abundant active sites. Moreover, Nafion incorporation in the nanocomposite can effectively increase the adhesion and mechanical strength of the film, and further improve the preconcetration ability due to the cation-exchange capacity of its abundant sulfonate groups. As expected, the (BiO)2CO3-rGO/Nafion nanocomposite-modified glassy carbon electrode ((BiO)2CO3-rGO-Nafion/GCE) achieved low detection limits of 0.24 μg/L for Pb(II) and 0.16 μg/L for Cd(II), in the linear range of 1.0–60 μg/L, and showed some excellent performance, such as high stability, good selectivity, and sensitivity. Finally, synthetic water samples were prepared and further used to verify the practicability of the (BiO)2CO3-rGO-Nafion/GCE with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Carbon 2D Materials-Based Field-Effect Transistor Biosensors: Recent Advances, Challenges, and Future Perspectives

In recent years, field-effect transistors (FETs) have been very promising for biosensor applications due to their high sensitivity, real-time applicability, scalability, and prospect of integrating measurement system on a chip. Non-carbon 2D materials, such as transition metal dichalcogenides (TMDCs), hexagonal boron nitride (h-BN), black phosphorus (BP), and metal oxides, are a group of new materials that have a huge potential in FET biosensor applications. In this work, we review the recent advances and remarkable studies of non-carbon 2D materials, in terms of their structures, preparations, properties and FET biosensor applications. We will also discuss the challenges facing non-carbon 2D materials-FET biosensors and their future perspectives.

2D-materials↗