Explosives Threat Assessment Working Group Terminology

This document contains a summary list of definitions for distribution to sites working with and working within the Department of Homeland Security’s Explosives Threat Assessment working group. The purpose of this list is to provide a unified framework for discussion between the various collaborating teams.

42 ENGINEERING↗

DSTL HMEX Reference QC Bounds Generation Using 2023 TP89 and Water Scans [Slides]

This presentation covers the results of new QC bounds generated using data from 10 TP89 reference specimen scans and 30 water scans acquired between January 12 and February 2, 2023. All scan data were acquired on the DSTL HMEX MCT system (in lead cabinet). All data presented were from DSTL’s reconstructions of recent HMEX scans.

42 ENGINEERING↗

HME MicroCT Data Acquisition, Processing and Data Request Overview

This document is a short summary of the steps required for MicroCT evaluation of a specimen. This includes data acquisition through image analysis, for the Explosives Threat Assessment (ETA) program. Expected outputs for each stage are outlined. Information and data shall be shipped to LLNL as described herein.

42 ENGINEERING↗

TP89 - SIRZ Decomposition Spectral Estimation (V.1.0)

The purpose of this test plan is to generate and evaluate calibrated system spectral response models for a dual-energy x-ray computed tomography (DECT) scanner. These spectral response models, which represent the energy distribution of photons observed by the detector with no test articles in the beam path, are necessary for spectral decomposition reconstruction techniques such as SIRZ, which are used for precise material characterization.

42 ENGINEERING↗

System-independent characterization of materials using dual-energy computed tomography

A system for characterizing the material of an object scanned via a dual-energy computed tomography scanner is provided. The system generates photoelectric and Compton sinograms based on a photoelectric-Compton decomposition of low-energy and high-energy sinograms generated from the scan and based on a scanner spectral response model. The system generates a Compton volume with Compton attenuation coefficients from the Compton sinogram and a photoelectric volume with photoelectric attenuation coefficients from the photoelectric sinogram. The system generates an estimated effective atomic number for a voxel and an estimated electron density for the voxel from the Compton attenuation coefficient and photoelectric coefficient for the voxel and scanner-specific parameters. The system then characterizes the material within the voxel based on the estimated effective atomic number and estimated electron density for the voxel. This information can be used to provide a mapping of known effective atomic numbers and known electron densities to known materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attenuation Drift in the Micro-Computed Tomography System at LLNL

The maximum allowable level of drift in the linear attenuation coefficients (μ) for a Lawrence Livermore National Laboratory (LLNL) micro-computed tomography (MCT) system was determined to be 0.1%. After ~100 scans were acquired during the period of November 2014 to March 2015, the drift in μ for a set of six reference materials reached or exceeded 0.1%. Two strategies have been identified to account for or correct the drift. First, normalizing the 160 kV and 100 kV μ data by the μ of water at the corresponding energy, in contrast to conducting normalization at the 160 kV energy only, significantly compensates for measurement drift. Even after the modified normalization, μ of polytetrafluoroethylene (PTFE) increases linearly with scan number at an average rate of 0.00147% per scan. This is consistent with PTFE radiation damage documented in the literature. The second strategy suggested is the replacement of the PTFE reference with fluorinated ethylene propylene (FEP), which has the same effective atomic number (Ze) and electron density (ρe) as PTFE, but is 10 times more radiation resistant. This is important as effective atomic number and electron density are key parameters in analysis. The presence of a material with properties such as PTFE, when taken together with the remaining references, allows for a broad range of the (Ze, ρe) feature space to be used in analysis. While FEP is documented as 10 times more radiation resistant, testing will be necessary to assess how often, if necessary, FEP will need to be replaced. As radiation damage to references has been observed, it will be necessary to monitor all reference materials for radiation damage to ensure consistent x-ray characteristics of the references.