Search NASA⌕ Search

Engineering topics

Segal, J.

Publications and source records attributed to Segal, J..

At least 19 records

3D Integrated Sensing Solutions

We will present the proposed research project to develop 3D-integrated sensors using advanced manufacturing capability for novel sensors, heterogeneously integrated with energy efficient readout circuits. The lack of precision timing in particle tracking detectors and the absence of low power, high throughput communications solutions to read them out limits progress in multiple fields of fundamental science. The aim of the project is to develop technology to enable large-scale particle detectors with 3D-integrated ASIC designs to simultaneously achieve 10 μm position resolution and 10 ps precision timing, with low-power consumption and high throughput rates. This research program leverages the unique combination of facilities and cross-disciplinary expertise of scientists and engineers at SLAC, FNAL, and LLNL and industrial partners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

200 mm sensor development using bonded wafers

Sensors fabricated from high resistivity, float zone, silicon material have been the basis of vertex detectors and trackers for the last 30 years. The areas of these devices have increased from a few square cm to > 200m 2 for the existing CMS tracker. High Luminosity Large Hadron Collider (HL-LHC), CMS and ATLAS tracker upgrades will each require more than 200 m 2 of silicon and the CMS High Granularity Calorimeter (HGCAL) will require more than 600 m 2 . The cost and complexity of assembly of these devices is related to the area of each module, which in turn is set by the size of the silicon sensors. In addition to large area, the devices must be radiation hard, which requires the use of sensors thinned to 200 microns or less. The combination of wafer thinning and large wafer diameter is a significant technical challenge, and is the subject of this work. In this paper we describe work on development of thin sensors on 200 mm wafers using wafer bonding technology. Results of development runs with float zone, Silicon-on-Insulator and Silicon-Silicon bonded wafer technologies are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution hypernuclear spectroscopy at Jefferson Lab, Hall A

The experiment E94-107 in Hall A at Jefferson Lab started a systematic study of high resolution hypernuclear spectroscopy in the 0 p -shell region of nuclei such as the hypernuclei produced in electroproduction on 9 Be, 12 C and 16 O targets. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring-imaging Cherenkov detector were added to the Hall A standard equipment. The high-quality beam, the good spectrometers and the new experimental devices allowed us to obtain very good results. Here, measurable strength with sub-MeV energy resolution was recorded for the core-excited states of $^{12}_{Λ}$B. A high-quality$^{16}_{Λ}N hypernuclear spectrum was likewise obtained. A first measurement of the Λ binding energy for Lambda 16N, calibrated against the elementary reaction on hydrogen, was obtained with high precision, 13.76 ± 0.16 MeV. Similarly, the first$^{9}_{Λ}Li hypernuclear spectrum shows general agreement with theory (distorted-wave impulse approximation with the SLA and BS3 electroproduction models and shell-model wave functions). Some disagreement exists with respect to the relative strength of the states making up the first multiplet. A Λ separation energy of 8.36 MeV was obtained, in agreement with previous results. It has been observed that the electroproduction of hypernuclei can provide information complementary to that obtained with hadronic probes and the γ-ray spectroscopy technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charge collection in irradiated HV-CMOS detectors

Active silicon detectors built on p-type substrate are a promising technological solution for large area silicon trackers such as those at the High Luminosity LHC, but the radiation hardness of this novel approach has to be evaluated. Active n-in-p strip detector prototypes CHESS2 for ATLAS with different substrate resistivities in the range of 20-1000 Omega cm were irradiated with neutrons and protons up to a fluence of 2 x 10(15) n(eq) cm(-2) and 3.6 x 10(15) n(eq) cm(-2). Charge collection in passive test structures on the chip was evaluated using Edge-TCT and minimum ionising electrons from Sr-90. Results were used to assess radiation hardness of the detector in the given fluence range and to determine parameters of initial acceptor removal in different substrates.

active silicon detectors↗

Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers

Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and FEL applications where high energy resolution (in the order of eV) is important. Increasing WDS energy resolution requires increasing spatial resolution of the detectors in the dispersion direction. The common approaches are not ideal: using strip detectors loses the 2D position sensitivity (important for, e.g., background estimation) and the high counting rate; using pixel detectors with a small pitch results in complex charge sharing behaviour and typically have a small size. Developing pixel detectors with high aspect ratio and a small pitch in the wavelength dispersive direction would be ideal, however, it would require a substantial ASIC development. We present a new approach, with a novel sensor design using rectangular pixels with a high aspect ratio (between strips and pixels, further called “strixels”), and strixel redistribution to match the square pixel arrays of typical ASICs. This results in a sensor area of 17.4 mm × 77 mm, with a fine pitch of 25 µm in the horizontal direction resulting in 3072 columns and 176 rows. The sensors use ePix100 readout ASICs, leveraging their low noise (43 e - , or 180 eV rms). We present results obtained with a Hammerhead ePix100 camera, showing that the small pitch (25 µm) in the dispersion direction maximizes performance for both high and low photon occupancies, resulting in optimal WDS energy resolution. The low noise level at high photon occupancy allows precise photon counting, while at low occupancy, both the energy and the subpixel position can be reconstructed for every photon, allowing an ultrahigh resolution (in the order of 1 µm) in the dispersion direction and rejection of scattered beam and harmonics. Using strixel sensors with redistribution and flip-chip bonding to standard ePix readout ASICs results in ultrahigh position resolution (~1 µm) and low noise in WDS applications, leveraging the advantages of hybrid pixel detectors (high production yield, good availability, relatively inexpensive) while minimizing development complexity through sharing the ASIC, hardware, software and DAQ development with other versions of ePix cameras.

47 OTHER INSTRUMENTATION↗

Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e - equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.

47 OTHER INSTRUMENTATION↗

JLab Measurements of the He 3 Form Factors at Large Momentum Transfers

The charge and magnetic form factors, F C and F M , respectively, of 3 He are extracted in the kinematic range 25 fm –2 ≤ Q 2 ≤ 61 fm –2 from elastic electron scattering by detecting 3 He recoil nuclei and scattered electrons in coincidence with the two High Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The measurements find evidence for the existence of a second diffraction minimum for the magnetic form factor at Q 2 = 49.3 fm –2 and for the charge form factor at Q 2 = 62.0 fm –2 . Both minima are predicted to exist in the Q 2 range accessible by this Jefferson Lab experiment. Here, the data are in qualitative agreement with theoretical calculations based on realistic interactions and accurate methods to solve the three-body nuclear problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analytical Solutions of Transient Drift-Diffusion in P-N Junction Pixel Sensors

Radiation detection in applications ranging from high energy physics to medical imaging rely on solid state detectors, often hybrid pixel detectors with (1) reverse biased p-n junction pixel sensors and (2) readout ASICs, attached by flip chip-bonding. Transient signals characteristics are important in, e.g., matching ASIC and sensor design, modeling and optimizing detector parameters and describing timing and charge sharing properties. Currently analytical forms of transient signals are available for only a few limited cases (e.g., drift or diffusion) or for the steady state (which is not relevant for high energy radiation detection). Tools are available for (relatively slow) numerical evaluation of the transient charge transport. We present here the first analytical solutions of partial differential equations de scribing drift-diffusion-recombination charge transport in planar p-n junction sensors in a variety of conditions: (1) undepleted, (2) fully depleted, (3) taking into account the gradual velocity saturation, and (4) overdepleted. We deduce the Green’s functions which can be applied to any detection problem through simple convolution with the initial conditions. We compare the analytical solutions with Monte Carlo simulations and industry standard simulations (Synopsys Sentaurus), demonstrating good agreement. Using the analytical equations enables fast modeling of the influence of various detector parameters on tracking, imaging and timing performance, describing performance and enabling optimizations for different applications. Finally, we illustrate this model with applications in 3D+T (x,y,z,time) photon tracking and 4D+T (x,y,θ,φ,time) relativistic charged particle tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardness studies of AMS HV-CMOS 350 nm prototype chip HVStripV1

CMOS active pixel sensors are being investigated for their potential use in the ATLAS inner tracker upgrade at the HL-LHC. The new inner tracker will have to handle a significant increase in luminosity while maintaining a sufficient signal-to-noise ratio and pulse shaping times. This paper focuses on the prototype chip "HVStripV1" (manufactured in the AMS HV-CMOS 350nm process) characterization before and after irradiation up to fluence levels expected for the strip region in the HL-LHC environment. The results indicate an increase of depletion region after irradiation for the same bias voltage by a factor of ≈2.4 and ≈2.8 for two active pixels on the test chip. As a result, there was also a notable increase in noise levels from 85 e – to 386 e – and from 75 e – to 277 e – for the corresponding pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Future of ePix detectors for high repetition rate FELs

Free-electron lasers (FELs) made the imaging of atoms and molecules in motion possible, opening new science opportunities with high brilliance, ultra-short x-ray laser pulses at up to 120 Hz. Some new or upgraded FEL facilities will operate at greatly increased pulse rates (kHz to MHz), presenting additional requirements on detection. We will present the ePix platform for x-ray detectors and the current status of the ePix detectors: ePix100 for low noise applications, ePix10k for high dynamic range applications, and ePixS for spectroscopic applications. Then we will introduce the plans to match the ePix detectors with the requirements of currently planned high repetition rate FELs (mainly readout speed and energy range).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗