Search NASA⌕ Search

Engineering topics

Seidl, P. A.

Publications and source records attributed to Seidl, P. A..

Carbon nanotube substrates enhance SARS-CoV-2 spike protein ion yields in matrix-assisted laser desorption–ionization mass spectrometry

Nanostructured surfaces enhance ion yields in matrix-assisted laser desorption–ionization mass spectrometry (MALDI-MS). The spike protein complex, S1, is one fingerprint signature of Sars-CoV-2 with a mass of 75 kDa. Here, we show that MALDI-MS yields of Sars-CoV-2 spike protein ions in the 100 kDa range are enhanced 50-fold when the matrix–analyte solution is placed on substrates that are coated with a dense forest of multi-walled carbon nanotubes, compared to yields from uncoated substrates. Nanostructured substrates can support the development of mass spectrometry techniques for sensitive pathogen detection and environmental monitoring.

60 APPLIED LIFE SCIENCES↗

Investigation of light ion fusion reactions with plasma discharges

The scaling of reaction yields in light ion fusion to low reaction energies is important for our understanding of stellar fuel chains and the development of future energy technologies. Experiments become progressively more challenging at lower reaction energies due to the exponential drop of fusion cross sections below the Coulomb barrier. We report on experiments where deuterium-deuterium (D-D) fusion reactions are studied in a pulsed plasma in the glow discharge regime using a benchtop apparatus. We model plasma conditions using particle-in-cell codes. Advantages of this approach are relatively high peak ion currents and current densities (0.1 to several A/cm 2 ) that can be applied to metal wire cathodes for several days. We detect neutrons from D-D reactions with scintillator-based detectors. For palladium targets, we find neutron yields as a function of cathode voltage that are over 100 times higher than yields expected for bare nuclei fusion at ion energies below 2 keV (center of mass frame). A possible explanation is a correction to the ion energy due to an electron screening potential of 1000 ± 250 eV, which increases the probability for tunneling through the repulsive Coulomb barrier. Finally, our compact, robust setup enables parametric studies of this effect at relatively low reaction energies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute calibration of GafChromic film for very high flux laser driven ion beams

We report on the calibration of GafChromic HD-v2 radiochromic film in the extremely high dose regime up to 100 kGy together with very high dose rates up to 7 × 10 11 Gy/s. The absolute calibration was done with nanosecond ion bunches at the Neutralized Drift Compression Experiment II particle accelerator at Lawrence Berkeley National Laboratory (LBNL) and covers a broad dose dynamic range over three orders of magnitude. We then applied the resulting calibration curve to calibrate a laser driven ion experiment performed on the BELLA petawatt laser facility at LBNL. Here, we reconstructed the spatial and energy resolved distributions of the laser-accelerated proton beams. The resulting proton distribution is in fair agreement with the spectrum that was measured with a Thomson spectrometer in combination with a microchannel plate detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of a Thomson parabola for fluence dependent energy-loss measurements at the Neutralized Drift Compression eXperiment

The interaction of ion beams with matter includes the investigation of the basic principles of ion stopping in heated materials. An unsolved question is the effect of different, especially higher, ion beam fluences on ion stopping in solid targets. This is relevant in applications such as in fusion sciences. To address this question, a Thomson parabola was built for the Neutralized Drift Compression eXperiment (NDCX-II) for ion energy-loss measurements at different ion beam fluences. The linear induction accelerator NDCX-II delivers 2 ns short, intense ion pulses, up to several tens of nC/pulse, or 1010-1011 ions, with a peak kinetic energy of ~1.1 MeV and a minimal spot size of 2 mm FWHM. For this particular accelerator, the energy determination with conventional beam diagnostics, for example, time of flight measurements, is imprecise due to the non-trivial longitudinal phase space of the beam. In contrast, a Thomson parabola is well suited to reliably determine the beam energy distribution. The Thomson parabola differentiates charged particles by energy and charge-to-mass ratio, through deflection of charged particles by electric and magnetic fields. During first proof-of-principle experiments, we achieved to reproduce the average initial helium beam energy as predicted by computer simulations with a deviation of only 1.4%25. Successful energy-loss measurements with 1 μm thick silicon nitride foils show the suitability of the accelerator for such experiments. The initial ion energy was determined during a primary measurement without a target, while a second measurement, incorporating the target, was used to determine the transmitted energy. The energy-loss was then determined as the difference between the two energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Source-to-accelerator quadrupole matching section for a compact linear accelerator

Recently, we presented a new approach for a compact radio-frequency (RF) accelerator structure and demonstrated the functionality of the individual components: acceleration units and focusing elements. In this paper, we combine these units to form a working accelerator structure: a matching section between the ion source extraction grids and the RF-acceleration unit and electrostatic focusing quadrupoles between successive acceleration units. The matching section consists of six electrostatic quadrupoles (ESQs) fabricated using 3D-printing techniques. The matching section enables us to capture more beam current and to match the beam envelope to conditions for stable transport in an acceleration lattice. We present data from an integrated accelerator consisting of the source, matching section, and an ESQ doublet sandwiched between two RF-acceleration units.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Staging of RF-accelerating Units in a MEMS-based Ion Accelerator

Multiple Electrostatic Quadrupole Array Linear Accelerators (MEQALACs) provide an opportunity to realize compact radio- frequency (RF) accelerator structures that can deliver very high beam currents. MEQALACs have been previously realized with acceleration gap distances and beam aperture sizes of the order of centimeters. Through advances in Micro-Electro-Mechanical Systems (MEMS) fabrication, MEQALACs can now be scaled down to the sub-millimeter regime and batch processed on wafer substrates. In this paper we show first results from using three RF stages in a compact MEMS-based ion accelerator. The results presented show proof-of-concept with accelerator structures formed from printed circuit boards using a 3 × 3 beamlet arrangement and noble gas ions at 10 keV. We present a simple model to describe the measured results. We also discuss some of the scaling behaviour of a compact MEQALAC. The MEMS-based approach enables a low-cost, highly versatile accelerator covering a wide range of currents (10 μA to 100 mA) and beam energies (100 keV to several MeV). Applications include ion-beam analysis, mass spectrometry, materials processing, and at very high beam powers, plasma heating.

43 PARTICLE ACCELERATORS↗

A compact linear accelerator based on a scalable microelectromechanical-system RF-structure

Here, a new approach for a compact radio-frequency (RF) accelerator structure is presented. The new accelerator architecture is based on the Multiple Electrostatic Quadrupole Array Linear Accelerator (MEQALAC) structure that was first developed in the 1980s. The MEQALAC utilized RF resonators producing the accelerating fields and providing for higher beam currents through parallel beamlets focused using arrays of electrostatic quadrupoles (ESQs). While the early work obtained ESQs with lateral dimensions on the order of a few centimeters, using a printed circuit board (PCB), we reduce the characteristic dimension to the millimeter regime, while massively scaling up the potential number of parallel beamlets. Using Microelectromechanical systems scalable fabrication approaches, we are working on further red ucing the characteristic dimension to the sub-millimeter regime. The technology is based on RF-acceleration components and ESQs implemented in the PCB or silicon wafers where each beamlet passes through beam apertures in the wafer. The complete accelerator is then assembled by stacking these wafers. This approach has the potential for fast and inexpensive batch fabrication of the components and flexibility in system design for application specific beam energies and currents. For prototyping the accelerator architecture, the components have been fabricated using the PCB. In this paper, we present proof of concept results of the principal components using the PCB: RF acceleration and ESQ focusing. Finally, ongoing developments on implementing components in silicon and scaling of the accelerator technology to high currents and beam energies are discussed.

43 PARTICLE ACCELERATORS↗

Irradiation of materials with short, intense ion pulses at NDCX-II

Here, we present an overview of the performance of the Neutralized Drift Compression Experiment-II (NDCX-II) accelerator at Berkeley Lab, and report on recent target experiments on beam-driven melting and transmission ion energy loss measurements with nanosecond and millimeter-scale ion beam pulses and thin tin foils. Bunches with around 10 11 ions, 1 mm radius, and 2–30 ns full width at half maximum duration have been created with corresponding fluences in the range of 0.1–0.7 J/cm 2 . To achieve these short pulse durations and mm-scale focal spot radii, the 1.1 MeV [megaelectronvolt (10 6 eV)] He + ion beam is neutralized in a drift compression section, which removes the space charge defocusing effect during final compression and focusing. The beam space charge and drift compression techniques resemble necessary beam conditions and manipulations in heavy ion inertial fusion accelerators. In conclusion, quantitative comparison of detailed particle-in-cell simulations with the experiment plays an important role in optimizing accelerator performance

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Short-pulse, compressed ion beams at the Neutralized Drift Compression Experiment

We have commenced experiments with intense short pulses of ion beams on the Neutralized Drift Compression Experiment (NDCX-II) at Lawrence Berkeley National Laboratory, with 1-mm beam spot size within 2.5 ns full-width at half maximum. The ion kinetic energy is 1.2 MeV. To enable the short pulse duration and mm-scale focal spot radius, the beam is neutralized in a 1.5-meter-long drift compression section following the last accelerator cell. A short-focal-length solenoid focuses the beam in the presence of the volumetric plasma that is near the target. In the accelerator, the line-charge density increases due to the velocity ramp imparted on the beam bunch. The scientific topics to be explored are warm dense matter, the dynamics of radiation damage in materials, and intense beam and beam-plasma physics including select topics of relevance to the development of heavy-ion drivers for inertial fusion energy. Below the transition to melting, the short beam pulses offer an opportunity to study the multi-scale dynamics of radiation-induced damage in materials with pump-probe experiments, and to stabilize novel metastable phases of materials when short-pulse heating is followed by rapid quenching. First experiments used a lithium ion source; a new plasma-based helium ion source shows much greater charge delivered to the target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and testing of a pulsed helium ion source for probing materials and warm dense matter studies

The neutralized drift compression experiment was designed and commissioned as a pulsed, linear induction accelerator to drive thin targets to warm dense matter (WDM) states with peak temperatures of ∼1 eV using intense, short pulses (∼1 ns) of 1.2 MeV lithium ions. At that kinetic energy, heating a thin target foil near the Bragg peak energy using He{sup +} ions leads to more uniform energy deposition of the target material than Li{sup +} ions. Experiments show that a higher current density of helium ions can be delivered from a plasma source compared to Li{sup +} ions from a hot plate type ion source. He{sup +} beam pulses as high as 200 mA at the peak and 4 μs long were measured from a multi-aperture 7-cm-diameter emission area. Within ±5% variation, the uniform beam area is approximately 6 cm across. The accelerated and compressed pulsed ion beams can be used for materials studies and isochoric heating of target materials for high energy density physics experiments and WDM studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗