Search NASA⌕ Search

Engineering topics

Seifert, Allen

Publications and source records attributed to Seifert, Allen.

51 records · Page 3

Measurement of 37Ar to support technology for On-site Inspection under the Comprehensive Nuclear-Test-Ban Treaty

On-Site Inspection (OSI) is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclide isotopes created by an underground nuclear explosion are a valuable signature of a Treaty violation. Argon-37 is produced from neutron interaction with calcium in soil, 40Ca(n,α)37Ar. For OSI, the 35-day half-life of 37Ar provides both high specific activity and sufficient time for completion of an inspection before decay limits sensitivity. This paper presents a low-background internal-source gas proportional counter with an 37Ar measurement sensitivity level equivalent to 45.1 mBq/SCM in whole air.

CTBT On-site Inspection↗

Low-Intrusion Techniques and Sensitive Information Management for Warhead Counting and Verification: FY2011 Annual Report

Future arms control treaties may push nuclear weapons limits to unprecedented low levels and may entail precise counting of warheads as well as distinguishing between strategic and tactical nuclear weapons. Such advances will require assessment of form and function to confidently verify the presence or absence of nuclear warheads and/or their components. Imaging with penetrating radiation can provide such an assessment and could thus play a unique role in inspection scenarios. Yet many imaging capabilities have been viewed as too intrusive from the perspective of revealing weapon design details, and the potential for the release of sensitive information poses challenges in verification settings. A widely held perception is that verification through radiography requires images of sufficient quality that an expert (e.g., a trained inspector or an image-matching algorithm) can verify the presence or absence of components of a device. The concept of information barriers (IBs) has been established to prevent access to relevant weapon-design information by inspectors (or algorithms), and has, to date, limited the usefulness of radiographic inspection. The challenge of this project is to demonstrate that radiographic information can be used behind an IB to improve the capabilities of treaty-verification weapons-inspection systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Non-Invertible Transforms for Image-Based Verification

Imaging may play a unique role in verifying the presence and distribution of warhead components in warhead counting and dismantlement settings where image information content can distinguish among shapes, forms, and material composition of items. However, a major issue with imaging is the high level of intrusiveness, and in particular, the possible need to store sensitive comparison images in the inspection system that would violate information barrier (IB) principles. Reducing images via transformations or feature extraction can produce image features (e.g. attributes) for verification, but with enough prior information about structure the reduced information itself may be sufficient to deduce sensitive details of the original image. Further reducing resolution of the transformed image information is an option, but too much reduction destroys the quality of the attribute. We study the possibility of a one-way transform that allows storage of non-sensitive reference information and analysis to enable comparison of transformed images within IB constraints. In particular, we consider the degree to which images can be reconstructed from image intensity histograms depending on the number of pixel intensity bins and the degree of frequency data quantization, as well as assumed knowledge of configuration of objects in the images. We also explore the concept of a 'perceptual hash' as a class of transforms that may enable verification with provable non-invertibility, leading to an effective one-way transform that preserves the nature of the image feature data without revealing sufficient information to reconstruct the original image.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase Contrast X-ray Imaging Signatures for Homeland Security Applications

Gratings-based phase contrast imaging is a promising new radiographic technique providing three distinct contrast mechanisms, absorption, phase, and scatter, using a conventional x-ray tube source. We investigate the signatures available in these three contrast mechanisms with particular attention towards potential homeland security applications. We find that the scatter mode in particular is sensitive to textured materials, enabling lowered detection limits than absorption for materials such as powders. We investigate the length scales to which our imaging system is sensitive.

99 GENERAL AND MISCELLANEOUS↗

IMAGE-BASED VERIFICATION: SOME ADVANTAGES, CHALLENGES, AND ALGORITHM-DRIVEN REQUIREMENTS

ABSTRACT Imaging technologies may be a particularly useful technique that supports monitoring and verification of deployed and stockpiled nuclear weapons and dismantlement components. However, protecting the sensitive design information requires processing the image behind an information barrier and reporting only non-sensitive attributes related to the image. Reducing images to attributes may destroy some sensitive information, but the challenge remains. For example, reducing the measurement to an attribute such as defined shape and X-ray transmission of an edge might reveal sensitive information relating to shape, size, and material composition. If enough additional information is available to analyze with the attribute, it may still be possible to extract sensitive design information. In spite of these difficulties, the implementation of new treaty requirements may demand image technology as an option. Two fundamental questions are raised: What (minimal) information is needed from imaging to enable verification, and what imaging technologies are appropriate? PNNL is currently developing a suite of image analysis algorithms to define and extract attributes from images for dismantlement and warhead verification and counting scenarios. In this talk, we discuss imaging requirements from the perspective of algorithms operating behind information barriers, and review imaging technologies and their potential advantages for verification. Companion talks will concentrate on the technical aspects of the algorithms.

IMAGE-BASED VERIFICATION: SOME ADVANTAGES, CHALLEN↗

Image-Based Verification Algorithms for Arms Control

PNNL is developing and evaluating radiographic image analysis techniques (active and passive) for verifying sensitive objects in a material control or warhead counting regime in which sensitive information may be acquired and processed behind an information barrier. Since sensitive image information cannot be present outside the information barrier, these techniques are necessary to extract features from the full images and reduce them to relevant parameters (attributes) of the inspected items. This evaluation can be done behind the information barrier, allowing for reporting and storage of non-sensitive attributes only. Several advances have been made to radiographic object verification algorithms, in the areas of spectral imaging for passive detectors and estimation of material density in active radiographic images. Both of these advances are pertinent in an arms control context. While passive radiographic images produced by previous work may be evaluated for the presence of emissive objects, approaches which leverage the spectroscopic potential of the detectors allow a much greater discrimination of SNM from background and other sources. Spectral passive imaging approaches to warhead discrimination and counting include specific materials and geometric arrangement localization, as well as “spectral difference” metrics which group regions with similar spectra together. These approaches may improve resolution for discrimination between materials in addition to locating SNM within surrounding shielding and/or structural elements. Previous work by our group has developed the capability to discern material density and composition in radiographic images by examining the edge transition characteristics of objects. The material construction of an object can be investigated in this way. In a weapons counting or discrimination context, unknown occultation of objects of interest, as well as additional elements of warhead construction, construction materials of varying geometry and makeup and various angles of radiograph are expected to impact algorithm performance. Advances in material discrimination algorithms are presented as a mechanism to help make these approaches robust to these sorts of variations.

Robinson, Sean M.↗

Imaging for dismantlement verification: information management and analysis algorithms

The level of detail discernible in imaging techniques has generally excluded them from consideration as verification tools in inspection regimes. An image will almost certainly contain highly sensitive information, and storing a comparison image will almost certainly violate a cardinal principle of information barriers: that no sensitive information be stored in the system. To overcome this problem, some features of the image might be reduced to a few parameters suitable for definition as an attribute. However, this process must be performed with care. Computing the perimeter, area, and intensity of an object, for example, might reveal sensitive information relating to shape, size, and material composition. This paper presents three analysis algorithms that reduce full image information to non-sensitive feature information. Ultimately, the algorithms are intended to provide only a yes/no response verifying the presence of features in the image. We evaluate the algorithms on both their technical performance in image analysis, and their application with and without an explicitly constructed information barrier. The underlying images can be highly detailed, since they are dynamically generated behind the information barrier. We consider the use of active (conventional) radiography alone and in tandem with passive (auto) radiography.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

INITIAL RESULTS: AN ULTRA-LOW-BACKGROUND GERMANIUM CRYSTAL ARRAY

ABSTRACT Treaty verification techniques, environmental surveillance, and physics experiments continue to require increased sensitivity for detecting and quantifying radionuclides of interest. This can be accomplished with new detector designs that establish high detection efficiency and reduced instrument backgrounds. Current research is producing an intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and sensitive gamma-gamma coincidence detection. The system design is optimized to accommodate filter paper samples, e.g., samples collected by the Radionuclide Aerosol Sampler/Analyzer (RASA). The system will provide high sensitivity for weak collections on atmospheric filter samples (e.g., < 105 fissions), as well as offering the potential to gather additional information from higher-activity filters using gamma cascade coincidence detection. The first of two HPGe crystal arrays in ultra-low-background vacuum cryostats has been assembled, with the second in progress. Traditional methods for constructing ultra-low-background detectors were followed, including use of materials known to be low in radioactive contaminants, use of ultra-pure reagents, and use of a clean room assembly. The cryostat is constructed mainly from copper electroformed into near-final geometry at Pacific Northwest National Laboratory. Details of the detector assembly, vacuum and thermal performance testing, and initial measurement results are presented.

Keillor, Martin E.↗

IMAGE ANALYSIS ALGORITHMS FOR DUAL MODE IMAGING SYSTEMS

The level of detail discernable in imaging techniques has generally excluded them from consideration as verification tools in inspection regimes where information barriers are mandatory. However, if a balance can be struck between sufficient information barriers and feature extraction to verify or identify objects of interest, imaging may significantly advance verification efforts. This paper describes the development of combined active (conventional) radiography and passive (auto) radiography techniques for imaging sensitive items assuming that comparison images cannot be furnished. Three image analysis algorithms are presented, each of which reduces full image information to non-sensitive feature information and ultimately is intended to provide only a yes/no response verifying features present in the image. These algorithms are evaluated on both their technical performance in image analysis and their application with or without an explicitly constructed information barrier. The first algorithm reduces images to non-invertible pixel intensity histograms, retaining only summary information about the image that can be used in template comparisons. This one-way transform is sufficient to discriminate between different image structures (in terms of area and density) without revealing unnecessary specificity. The second algorithm estimates the attenuation cross-section of objects of known shape based on transition characteristics around the edge of the object’s image. The third algorithm compares the radiography image with the passive image to discriminate dense, radioactive material from point sources or inactive dense material. By comparing two images and reporting only a single statistic from the combination thereof, this algorithm can operate entirely behind an information barrier stage. Together with knowledge of the radiography system, the use of these algorithms in combination can be used to improve verification capability to inspection regimes and improve and substantially increase the likelihood of detecting material diversion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and Construction of an Ultra-Low-Background 14 Crystal Germanium Array for High Efficiency and Coincidence Measurements

ABSTRACT Physics experiments, environmental surveillance, and treaty verification techniques continue to require increased sensitivity for detecting and quantifying radionuclides of interest. This can be done by detecting a greater fraction of gamma emissions from a sample (higher detection efficiency) and reducing instrument backgrounds. A current effort for increased sensitivity in high resolution gamma spectroscopy will produce an intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and useful coincidence efficiencies. The system design is optimized to accommodate filter paper samples, e.g. samples collected by the Radionuclide Aerosol Sampler/Analyzer (RASA). The system will provide high sensitivity for weak collections on atmospheric filter samples, as well as offering the potential to gather additional information from more active filters using gamma cascade coincidence detection. The current effort is constructing an ultra-low-background HPGe crystal array consisting of two vacuum cryostats, each housing a hexagonal array of 7 crystals on the order of 70% relative efficiency per crystal. Traditional methods for constructing ultra-low-background detectors are used, including use of materials known to be low in radioactive contaminants, use of ultra pure reagents, clean room assembly, etc. The cryostat will be constructed mainly from copper electroformed into near-final geometry at PNNL. Details of the detector design, simulation of efficiency and coincidence performance, HPGe crystal testing, and progress on cryostat construction are presented.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design and construction of a low-background, internal-source proportional counter

Abstract High-purity copper has emerged as a preferred construction material for ultra-low-background HPGe spectrometers and offers excellent bulk radiopurity along with good electrical, thermal, and vacuum properties. Recently, these materials and techniques have been applied to the construction of low-background internal-source gas proportional counters. This work describes the design, construction, and testing of an ultra-low-background internal-source gas proportional counter built primarily of high purity electroformed copper. Energy resolution of *10% FWHM at 59.5 keV has been achieved, a lowenergy threshold of *3 keV has been reached, and gas gain stability over a 4-week period has been demonstrated. Progress toward low-background operation is described.

Electroformed copper↗

ASSEMBLY AND INITIAL RESULTS: AN ULTRA-LOW-BACKGROUND GERMANIUM CRYSTAL ARRAY FOR HIGH EFFICIENCY AND COINCIDENCE MEASUREMENTS

ABSTRACT Treaty verification, environmental surveillance, and physics experiments continue to require increased sensitivity for detecting and quantifying radionuclides of interest using gamma-ray spectrometry. This can be accomplished by establishing high detection efficiency and reducing instrument backgrounds. A current effort for increased sensitivity in high resolution gamma spectroscopy will produce an intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and useful coincidence efficiencies. The system design is optimized to accommodate filter paper samples, e.g. samples collected by the Radionuclide Aerosol Sampler/Analyzer (RASA). The system will provide high sensitivity for weak collections on atmospheric filter samples, as well as offering the potential to gather additional information from more active filters using gamma cascade coincidence detection. The instrument will also be capable of making advances in low-dose neutron activation analysis. The first of two ultra-low-background vacuum cryostats has been assembled, with a second in progress. Traditional methods for constructing ultra-low-background detectors were followed, including use of materials known to be low in radioactive contaminants, use of ultra pure reagents, clean room assembly, etc. The cryostat is constructed mainly from copper electroformed into near-final geometry at Pacific Northwest National Laboratory. Details of the detector assembly, vacuum tests, and test measurement results are presented.

ULTRA-LOW-BACKGROUND, GERMANIUM CRYSTAL ARRAY, COI↗

Initial Component Testing for a Germanium Array Cryostat

This report describes progress on the construction of two ultra-low-background cryostats that are part of the NA-22 funded “Radionuclide Laboratories” (RN Labs) project. Each cryostat will house seven high-purity germanium crystals (HPGe). These cryostats are being built from a limited set of materials that are known to have very low levels of radioactive impurities. The RN Labs instrument is designed to take advantage of low background performance, high detection efficiency, and γ-γ coincidence signatures to provide unprecedented gamma spectroscopy sensitivity. The project is focused on improving gamma analysis capabilities for nuclear detonation detection (NDD) applications. The instrument also has the potential for basic nuclear physics research. Section 1 provides the background for the project. Section 2 discusses germanium crystal acceptance testing. Design problems were found after the first delivery of new detectors from the vendor, Canberra Semiconductors. The first four crystals were returned for repair, resulting in a delay in crystal procurement. Section 3 provides an update on copper electroforming. In general, electroforming parts for RN Labs has proceeded smoothly, but there have been recent problems in electroforming three large copper parts necessary for the project. Section 4 describes the first round of testing for the instrument: anti-cosmic scintillator testing, electronics testing, and initial vacuum testing. Section 5 concludes with an overall description of the state of the project and challenges that remain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternative treaty monitoring approaches using ultra-low background measurement technology

The International Monitoring System (IMS) of the Comprehensive Test Ban Treaty includes a network of stations and laboratories for collection and analysis of radioactive aerosols. Alternative approaches to IMS operations are considered as a method of enhancing treaty verification. Ultra-low background (ULB) detection promises the possibility of improvements to IMS minimum detectable activities (MDAs) well below the current approach, requiring MDAp30 mBq/m3 of air for 140Ba, or about 106 fissions per daily sample.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗