Search NASA⌕ Search

Engineering topics

Seka, W.

Publications and source records attributed to Seka, W..

Inferences of hot electron preheat and its spatial distribution in OMEGA direct drive implosions

Hot electrons generated from laser plasma instabilities degrade performance of direct drive implosions by preheating the deuterium and tritium (DT) fuel resulting in early decompression and lower areal densities at stagnation. A technique to quantify the hot electron preheat of the dense DT fuel and connect it to the degradation in areal density is described in detail. Hot electrons are measured primarily from the hard x-rays they emit as they slow down in the target. The DT preheat is inferred from a comparison of the hard x-ray signals between a DT-layered implosion and its mass equivalent ablator only implosion. The preheat energy spatial distribution within the imploding shell is inferred from experiments using high Z payloads of varying thicknesses. It is found that the electrons deposit their energy uniformly throughout the shell material. For typical direct-drive OMEGA implosions driven with an overlapped intensity of ∼9·1014 W/cm2, approximately ∼0.02%–0.03% of the laser energy is converted into preheat of the stagnated fuel which corresponds to areal density degradations of 10%–20%. The degradations in areal density explain some of the observed discrepancies between the simulated and measured areal densities.

Christopherson, A. R. (ORCID:000000033578635X)↗

Hot-electron preheat and mitigation in polar-direct-drive experiments at the National Ignition Facility

Target preheat by superthermal electrons from laser–plasma instabilities is a major obstacle to achieving thermonuclear ignition via direct-drive inertial confinement fusion at the National Ignition Facility (NIF). Polar-direct-drive surrogate plastic implosion experiments were performed on the NIF to quantify preheat levels at ignition-relevant scale and develop mitigation strategies. Here, the experiments were used to infer the hot-electron temperature, energy fraction, divergence, and to directly measure the spatial hot-electron energy deposition profile inside the imploding shell. Silicon layers buried in the ablator are shown to mitigate the growth of laser–plasma instabilities and reduce preheat, providing a promising path forward for ignition designs at an on-target intensity of about 10 15 W/cm 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct Measurements of DT Fuel Preheat from Hot Electrons in Direct-Drive Inertial Confinement Fusion

Hot electrons generated by laser-plasma instabilities degrade the performance of laser-fusion implosions by preheating the DT fuel and reducing core compression. The hot-electron energy deposition in the DT fuel has been directly measured for the first time by comparing the hard x-ray signals between DT-layered and mass-equivalent ablator-only implosions. The electron energy deposition profile in the fuel is inferred through dedicated experiments using Cu-doped payloads of varying thickness. The measured preheat energy accurately explains the areal-density degradation observed in many OMEGA implosions. This technique can be used to assess the viability of the direct-drive approach to laser fusion with respect to the scaling of hot-electron preheat with laser energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Measurements of DT Fuel Preheat from Hot Electrons in Direct-Drive Inertial Confinement Fusion

Hot electrons generated by laser-plasma instabilities degrade the performance of laser-fusion implosions by preheating the DT fuel and reducing core compression. The hot-electron energy deposition in the DT fuel has been directly measured for the first time by comparing the hard x-ray signals between DT-layered and mass-equivalent ablator-only implosions. The electron energy deposition profile in the fuel is inferred through dedicated experiments using Cu-doped payloads of varying thickness. The measured preheat energy accurately explains the areal-density degradation observed in many OMEGA implosions. Furthermore, this technique can be used to assess the viability of the direct-drive approach to laser fusion with respect to the scaling of hot-electron preheat with laser energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National direct-drive program on OMEGA and the National Ignition Facility

A major advantage of the laser direct-drive (DD) approach to ignition is the increased fraction of laser drive energy coupled to the hot spot and relaxed hot-spot requirements for the peak pressure and convergence ratios relative to the indirect-drive approach at equivalent laser energy. With the goal of a successful ignition demonstration using DD, the recently established national strategy has several elements and involves multiple national and international institutions. These elements include the experimental demonstration on OMEGA cryogenic implosions of hot-spot conditions relevant for ignition at MJ-scale energies available at the National Ignition Facility (NIF) and developing an understanding of laser-plasma interactions and laser coupling using DD experiments on the NIF. DD designs require reaching central stagnation pressures in excess of 100 Gbar. The current experiments on OMEGA have achieved inferred peak pressures of 56 Gbar (Regan et al 2016 Phys. Rev. Lett. 117 025001). Extensive analysis of the cryogenic target experiments and two- and three-dimensional simulations suggest that power balance, target offset, and target quality are the main limiting factors in target performance. In addition, cross-beam energy transfer (CBET) has been identified as the main mechanism reducing laser coupling. Reaching the goal of demonstrating hydrodynamic equivalence on OMEGA includes improving laser power balance, target position, and target quality at shot time. CBET must also be significantly reduced and several strategies have been identified to address this issue. (2016-01-01)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hot-electron generation at direct-drive ignition-relevant plasma conditions at the National Ignition Facility

Laser–plasma interaction instabilities can be detrimental for direct-drive inertial confinement fusion by generating high-energy electrons that preheat the target. Moreover, an experimental platform has been developed and fielded on the National Ignition Facility to investigate hot-electron production from laser–plasma instabilities at direct-drive ignition-relevant conditions. The radiation-hydrodynamic code DRACO has been used to design planar-target experiments that generate plasma and interaction conditions comparable to direct-drive ignition designs: I L ~10 15 W/cm 2 , T e > 3 keV, and density-gradient scale lengths of L n ~ 600 μ m in the quarter-critical density region. The hot-electron properties were inferred by comparing the experimentally observed hard x-ray spectra to Monte Carlo simulations of hard x-ray emission from hot electrons depositing energy in the target. Hot-electron temperatures of ~40 keV to 60 keV and the fraction of laser energy converted to hot electrons of ~0.5% to 5% were inferred in plastic targets for laser intensities at the quarter-critical density surface of (~4 to 14) × 10 14 W/cm 2 . The use of silicon ablators was found to mitigate the hot-electron preheat by increasing the threshold laser intensity for hot-electron generation from ~3.5 × 10 14 W/cm 2 in plastic to ~6 × 10 14 W/cm 2 in silicon. The overall hot-electron production is further reduced in silicon ablators when the intensity threshold is exceeded.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anomalous Absorption by the Two-Plasmon Decay Instability

Radiation-hydrodynamic simulations of directly driven fusion experiments at the Omega Laser Facility predict absorption accurately when targets are driven at low overlapped laser intensity. Discrepancies appear at increased intensity, however, with higher-than-expected laser absorption on target. Strong correlations with signatures of the two-plasmon decay (TPD) instability—including half-harmonic and hard-x-ray emission—indicate that TPD is responsible for this anomalous absorption. Scattered light data suggest that up to ≈ 30 % of the laser power reaching quarter-critical density can be absorbed locally when the TPD threshold is exceeded. A scaling of absorption versus TPD threshold parameter was empirically determined and validated using the laser–plasma simulation environment code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stimulated Raman scattering mechanisms and scaling behavior in planar direct-drive experiments at the National Ignition Facility

Stimulated Raman scattering (SRS) has been investigated comprehensively in planar-geometry experiments at the National Ignition Facility at conditions relevant to the corona of inertial con finement fusion (ICF) ignition-scale direct-drive targets. These experiments at measured electron temperatures of 4 to 5 keV, simulated density scale lengths Ln of 400 to 700 um, and laser intensities at the quarter-critical density of up to 1.5 x 10 15 W/cm 2 have determined SRS thresholds and the scaling behavior of SRS for various beam geometries. Several SRS mechanisms, including saturated absolute SRS near the quarter-critical density and additional SRS, including near-backscatter or sidescatter at lower densities, have been identi fied. Correlation of time-dependent SRS at densities ~0.15 to 0.21 of the critical density with hot-electron signatures, as well as the magnitudes of these signatures across different experiments, is observed. Additional modeling work is needed to de nitively identify the density region in which hot electrons are generated, and will guide SRS and hot-electron preheat mitigation strategies for direct-drive-ignition designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inferred UV fluence focal-spot profiles from soft x-ray pinhole-camera measurements on OMEGA

A method was developed with laser-irradiated Au planar foils to characterize the focal spot of UV laser beams on target at full energy from soft x-ray emission. A pinhole camera with a back-thinned charge-coupled–device detector and filtration with thin Be and Al foil filters provides images of the x-ray emission at photon energies <2 keV. This method requires a careful measurement of the relation between the applied UV fluence and the x-ray signal, which can be described by a power-law dependence. The measured exponent γ ~ 2 provides a dynamic range of ~25 for the inferred UV fluence. UV fluence profiles of selected beams were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from an UV equivalent-target-plane diagnostic. The inferred spot size and super-Gaussian order from the x-ray technique agree within several percent with the values measured with the direct UV measurements.

47 OTHER INSTRUMENTATION↗