Search NASA⌕ Search

Engineering topics

Sekutowicz, Jacek

Publications and source records attributed to Sekutowicz, Jacek.

Optimization of cathodic arc deposition and pulsed plasma melting techniques for growing smooth superconducting Pb photoemissive films for SRF injectors

Superconducting photoinjectors have a potential to be the optimal solution for moderate and high current cw operating free electron lasers. For this application, a superconducting lead (Pb) cathode has been proposed to simplify the cathode integration into a 1.3 GHz, TESLA-type, 1.6-cell long purely superconducting gun cavity. In the proposed design, a lead film several micrometres thick is deposited onto a niobium plug attached to the cavity back wall. Traditional lead deposition techniques usually produce very non-uniform emission surfaces and often result in a poor adhesion of the layer. A pulsed plasma melting procedure reducing the non-uniformity of the lead photocathodes is presented. In order to determine the parameters optimal for this procedure, heat transfer from plasma to the film was first modelled to evaluate melting front penetration range and liquid state duration. The obtained results were verified by surface inspection of witness samples. The optimal procedure was used to prepare a photocathode plug, which was then tested in an electron gun. In conclusion, the quantum efficiency and the value of cavity quality factor have been found to satisfy the requirements for an injector of the European-XFEL facility.

42 ENGINEERING↗

Review of R&D at DESY on ingot niobium for accelerators

An R&D program at DESY exploring the potential of the production of 1.3 GHz TESLA shape cavities from large grain or ingot niobium material has been carried out as a feasibility study for using ingot niobium material for the European X-ray Free-Electron Laser project. The most important issues like feasibility of the fabrication of niobium discs from ingots, material properties, cavity fabrication, treatment, and finally the cryogenic radiofrequency (RF) performance of the cavity in the accelerator modules are presented and discussed. At least 25% higher intrinsic quality factor comparing to conventional fine-grain niobium and high accelerating gradient of up to 45 MV/m have been demonstrated during the cryogenic RF tests both in the vertical cryostats and in a completely assembled accelerating cryo-module.

43 PARTICLE ACCELERATORS↗

Towards a 100mA Superconducting RF Photoinjector for BERLinPro

For BERLinPro, a 100 mA CW-driven SRF energy recovery linac demonstrator facility, HZB needs to develop a photo-injector superconducting cavity which delivers a at least 1mm*mr emittance beam at high average current. To address these challenges of producing a high peak brightness beam at high repetition rate, at first HZB tested a fully superconducting injector with a lead cathode*,followed now by the design of a SC cavity allowing operation up to 4 mA using CW-modified TTF-III couplers and inserting a normal conducting high quantum efficiency cathode using the HZDR-style insert scheme. This talk will present the latest results and an overview of the measurements with the lead cathode cavity and will describe the design and optimization process, the first production results of the current design and an outlook to the further development steps towards the full power version.

Neumann, Axel↗

Update on Coaxial Coupling Scheme for ILC-type Niobium Cavities

We have in the past reported about our efforts to develop a flangeable coaxial coupler for both HOM and fundamental coupling for 9-cell ILC-type cavities. The design of the coupler was done in a way, that the rf magnetic fields at the flange connection were minimized and only a field of <5 mT would be present for a magnetic field of 160 mT ( Eacc ~ 35 MV/m) in the cavity. Even though we achieved reasonably high Q-values at low field, the cavity/coupler combination was limited to only ~ 7 MV/m in the cavity, where a thermally initiated degradation occurred. We believed that this limitation was caused by poor cooling of the shorting plate in the coaxial coupler; therefore, we have improved the cooling conditions by drilling radial cooling channels into the shorting plate. This paper reports about our experiences with the modified conditions.

Kneisel, Peter↗

Coaxial coupling scheme for fundamental and higher order modes in superconducting cavities

Higher Order Modes generated by a particle beam passing through a superconducting accelerating cavity have to be damped to avoid beam instabilities. A coaxial coupler located in the beam pipes of the cavities provides for better propagation of HOMs and strong damping in appropriate HOM dampers. The whole damping device can be designed as a detachable system. If appropriately dimensioned, the RF currents can be minimized at the flange position. Additionally, the coaxial system also provides efficient coupling of fundamental mode RF power into the superconducting cavity. Compared to presently available solutions for HOM damping, this scheme provides for several advantages: stronger HOM damping, attachable solution, and exchangeability of the HOM damping device on a cavity, less complexity of the superconducting cavity, possible cost advantages. This contribution discusses modeling, which lead to an optimized layout of a cavity-coupler system and describes results from the room temperature and first cryogenic temperature measurements .

Sekutowicz, Jacek↗

Progress on the Development of a Superconducting Connection for Niobium Cavities

The availability of a superconducting connection between adjacent niobium radio-frequency (RF) cavities with the capability to carry up to 30 mT of the magnetic flux would be particularly of great benefit to layouts of long accelerators like the International Linear Collider (ILC). It would shorten the distances between structures and therefore the total length of an accelerator with the associated cost reductions. In addition, the superconducting connection would be ideal for a superstructure – two multi-cell cavities connected through a half wavelength long beam pipe providing the coupling. Two single-cell niobium cavities have been designed with Nb-1Zr flanges welded to one of the irises to allow a connection between them with a niobium gasket. A transition to the normal-conducting state of the connection due to the applied RF field causes a reduction of the cavities’ quality factor. The cavity design will be presented in this contribution along with possible choices of materials for the joint.

43 PARTICLE ACCELERATORS↗

Coaxial coupling scheme for fundamental and higher order modes in superconducting cavities

Higher Order Modes generated by a particle beam passing through a superconducting accelerating cavity have to be damped to avoid beam instabilities. A coaxial coupler located in the beam pipes of the cavities provides for better propagation of HOMs and strong damping in appropriate HOM dampers. The whole damping device can be designed as a detachable system. If appropriately dimensioned, the RF currents can be minimized at the flange position. Additionally, the coaxial system also provides efficient coupling of fundamental mode RF power into the superconducting cavity. Compared to presently available solutions for HOM damping, this scheme provides for several advantages: stronger HOM damping, attachable solution, and exchangeability of the HOM damping device on a cavity, less complexity of the superconducting cavity, possible cost advantages. This contribution discusses modeling, which lead to an optimized layout of a cavity-coupler system and describes results from the room temperat

43 PARTICLE ACCELERATORS↗

Observation and Mitigation of Multipass BBU in CEBAF

Abstract The Continuous Electron Beam Accelerator Facility (CEBAF) recirculating accelerator at Jefferson Lab consists of two linacs carrying beam for up to five passes of acceleration. The design of this accelerator anticipated the onset of multipass beam break-up (BBU) at a beam current of approximately 20 mA, far above the operational peak current of 200 uA. For more than a decade of operation, no sign of BBU was ever observed. However, a specially designed acceleration cavity in a cryomodule installed in the summer of 2007 has been observed to cause BBU instability with as low as 40 uA of injected beam current. This presented an opportunity to study BBU in a five-pass accelerator. In this paper we will discuss multipass BBU, present observational data, and discuss the ways we have developed to maintain the instability threshold current to values above those required for operation.

43 PARTICLE ACCELERATORS↗

Superstructure for high current applications in superconducting linear accelerators

A superstructure for accelerating charged particles at relativistic speeds. The superstructure consists of two weakly coupled multi-cell subunits equipped with HOM couplers. A beam pipe connects the subunits and an HOM damper is included at the entrance and the exit of each of the subunits. A coupling device feeds rf power into the subunits. The subunits are constructed of niobium and maintained at cryogenic temperatures. The length of the beam pipe between the subunits is selected to provide synchronism between particles and rf fields in both subunits.

43 PARTICLE ACCELERATORS↗