Search NASA⌕ Search

Engineering topics

Self, D. A.

Publications and source records attributed to Self, D. A..

Pulmonary blood flow redistribution by increased gravitational force

This study was undertaken to assess the influence of gravity on the distribution of pulmonary blood flow (PBF) using increased inertial force as a perturbation. PBF was studied in unanesthetized swine exposed to -Gx (dorsal-to-ventral direction, prone position), where G is the magnitude of the force of gravity at the surface of the Earth, on the Armstrong Laboratory Centrifuge at Brooks Air Force Base. PBF was measured using 15-micron fluorescent microspheres, a method with markedly enhanced spatial resolution. Each animal was exposed randomly to -1, -2, and -3 Gx. Pulmonary vascular pressures, cardiac output, heart rate, arterial blood gases, and PBF distribution were measured at each G level. Heterogeneity of PBF distribution as measured by the coefficient of variation of PBF distribution increased from 0.38 +/- 0.05 to 0.55 +/- 0.11 to 0.72 +/- 0.16 at -1, -2, and -3 Gx, respectively. At -1 Gx, PBF was greatest in the ventral and cranial and lowest in the dorsal and caudal regions of the lung. With increased -Gx, this gradient was augmented in both directions. Extrapolation of these values to 0 G predicts a slight dorsal (nondependent) region dominance of PBF and a coefficient of variation of 0.22 in microgravity. Analysis of variance revealed that a fixed component (vascular structure) accounted for 81% and nonstructure components (including gravity) accounted for the remaining 19% of the PBF variance across the entire experiment (all 3 gravitational levels). The results are inconsistent with the predictions of the zone model.

NASA Discipline Cardiopulmonary↗

Effect of upright tilt on ventricular/vascular coupling in chronically instrumented primates

Studies of the hydraulic loading conditions on the heart in humans, especially pulsatile load, have primarily been limited to the supine state. Therefore, we have chosen a nonhuman primate model, the baboon, to assess left ventricular/vascular coupling in both supine and upright positions. Primate subjects were studied by catheterization under sedation and then after surgical implantation of transducers. This allowed the evaluation of postural stress in the chronically instrumented conscious baboon and then after light dissociative doses of ketamine. Basic hemodynamic variables were evaluated for baboons in supine and upright positions. Fourier analysis was applied to aortic pressure and flow to obtain input and characteristic impedance and the ratio of pulsatile (Wp) to total (Wt) left ventricular power (Wp/Wt). The aortic reflected, or backward, pressure was also calculated. Peripheral resistance increased (P = 0.01) and reflected pressure decreased (17.74 +/- 1.50 vs. 15.21 +/- 2 mmHg; P < 0.01) in upright subjects. Characteristic impedance and Wp/Wt were unchanged. Postoperatively, peripheral resistance increased (2,651 +/- 311 vs. 3,667 +/- 276; P < 0.05) and mean power and Wt decreased (P < 0.01) without changes in reflected pressure. All variables were unchanged after light dissociative doses of ketamine. Thus there is no significant change in efficiency of left ventricular/vascular coupling formulated in terms of Wp/Wt or input impedance with postural stress.

NASA Program Space Physiology and Countermeasures↗