Resilient cooling strategies – A critical review and qualitative assessment

The global effects of climate change will increase the frequency and intensity of extreme events such as heatwaves and power outages, which have consequences for buildings and their cooling systems. Buildings and their cooling systems should be designed and operated to be resilient under such events to protect occupants from potentially dangerous indoor thermal conditions. This study performed a critical review on the state-of-the-art of cooling strategies, with special attention to their performance under heatwaves and power outages. We proposed a definition of resilient cooling and described four criteria for resilience—absorptive capacity, adaptive capacity, restorative capacity, and recovery speed —and used them to qualitatively evaluate the resilience of each strategy. The literature review and qualitative analyses show that to attain resilient cooling, the four resilience criteria should be considered in the design phase of a building or during the planning of retrofits. The building and relevant cooling system characteristics should be considered simultaneously to withstand extreme events. A combination of strategies with different resilience capacities, such as a passive envelope strategy coupled with a low-energy space-cooling solution, may be needed to obtain resilient cooling. Finally, a further direction for a quantitative assessment approach has been pointed out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal performance and potential annual energy impact of retrofit thin-glass triple-pane glazing in US residential buildings

Heat transfer through the building envelope and associated air leakage comprise the largest HVAC loads in most climates, and windows, which are known as the weakest link in the thermal envelope, are responsible for about 5 Quads, or approximately 10%, of building energy use. Therefore, windows offer a significant opportunity for building energy savings. High performance windows, such as triple glazing, though comprised of less than 2% of all US window sales in 2016 and has remained stagnant because they typically require a full and expensive redesign of the typical window sash and frame. One potential low incremental cost solution to kick start the market is upgrading the glazing with a thin-glass triple-pane design that does not require modifications to existing frame and sash. Here in this work, we first define the characteristics and performance of current “typical” residential windows through an examination of the National Fenestration Rating Council (NFRC) Certified Products Directory (CPD). With knowledge of the typical window, we determine the potential thermal performance impact of replacing typical glazing with thin-glass triple-pane glazing. Finally, with an understanding of the potential improvements to traditional performance metrics, such as U-factor, we show the energy savings potential of the thin-triple glazing in place of typical low-e windows in residential buildings is 16% in heating dominated climates such as Minneapolis, MN, 12% in mixed climates such as Washington DC, and 7% in cooling dominated climates such as Houston, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Breaking the 20 Year Logjam to Better Insulating Windows

Windows account for about 4 Quads of US energy consumption or 12% of building energy use. After 20 years of public/private investment (from 1980 to 2000) in technology R&D, coupled with new rating and labeling organizations (NFRC) and with subsequent voluntary ENERGY STAR programs and tighter codes and standards, windows using low-E/argon gas fill (~R3) gained a dominant market share and now account for >86% of all annual sales. However, this remarkable transformation of prior markets has stagnated, with triple glazing (~R5-R7) comprising less than 2% of all window sales in 2016. U.S. Department of Energy (DOE) estimates the national technical potential savings using R5-R7 windows at ~ 2Q annually, but manufacturers claim they would have to redesign their entire sash/frame inventory to accommodate the thicker and heavier insulating glass units (IGUs) in conventional triple glazed window designs. This paper outlines the initial findings from the first phase of a new collaborative effort, now underway with industry partners, to transform window markets to the R5-R7 insulating levels by introducing a novel packaging of existing technology elements, implemented as a “drop-in replacement” for current IGUs. The program involves working with supply chain partners to ensure component availability, with leading window manufacturers to integrate the key technology elements and initially deploy the new designs, and with market pull partners to speed adoptions rates. Market pull partners include building code officials, utility rebate/incentive programs and ENERGY STAR, along with early adopters such as builders targeting net zero and passive house designers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Performance Building Mockup in FLEXLAB

Genentech has ambitious energy and indoor environmental quality performance goals for Building 35 (B35) being constructed by Webcor at the South San Francisco campus. Genentech and Webcor contracted with the Lawrence Berkeley National Laboratory (LBNL) to test building systems including lighting, lighting controls, shade fabric, and automated shading controls in LBNL’s new FLEXLAB facility. The goal of the testing is to ensure that the systems installed in the new office building will function in a way that reduces energy consumption and provides a comfortable work environment for employees.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comparative energy analysis of three electrochromic glazing technologies in commercial and residential buildings

Here, we present a simulation study of three dynamic electrochromic window glazings, including a novel glazing capable of independently modulating its optical properties in both the visible and near-infrared spectrums. This capability allows this so-called “dual-band” technology to actively manage the solar heat and visible light transmitted into a building's interior, and creates the potential for heating, cooling, and lighting savings vis-à-vis competing window technologies. In this study EnergyPlus is used to simulate annual energy performance of the dual-band electrochromic (DBEC) glazing in three building types and 16 U.S. climate regions. The savings potential of DBEC windows are presented relative to a conventional electrochromic glazing; a visibly transparent, near-infrared switching electrochromic glazings; and several static alternatives, including ASHRAE 90-2010 standard compliant windows. Results indicate that the DBEC glazings are capable of outperforming alternatives in a diverse set of locations and building types, including both heating and cooling-dominated regions. Relative to code-compliant static windows, the DBEC is capable of achieving annual primary energy savings between 6 and 30 kW h/ft 2 of window area from reduced heating, cooling, and lighting demand. Relative to other advanced glazings, the savings are significantly lower, ranging from 0 to 1.2 kW h/ft 2 . Regional DBEC energy cost savings versus high performance static windows are presented to identify early potential market entries based on energy savings. Lastly, the impacts of widespread deployment of high-efficiency LED lighting on DBEC energy savings potentials are also presented.

14 SOLAR ENERGY↗

Technology Assessments of High Performance Envelope with Optimized Lighting, Solar Control, and Daylighting

The objective of this monitored field study was to identify near-term innovative façade technologies for solar control and daylighting with a goal of 20-40% energy use savings below Title 24 2013 in the 30-ft deep perimeter zone near vertical windows within cost and comfort constraints. The targeted market was new or existing commercial office buildings or buildings with similar patterns of use.