Selzer, Robert H.

Publications and source records attributed to Selzer, Robert H..

Split-screen display system and standardized methods for ultrasound image acquisition and multi-frame data processing

A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.

Selzer, Robert H.↗

System and method for improving ultrasound image acquisition and replication for repeatable measurements of vascular structures

High resolution B-mode ultrasound images of the common carotid artery are obtained with an ultrasound transducer using a standardized methodology. Subjects are supine with the head counter-rotated 45 degrees using a head pillow. The jugular vein and carotid artery are located and positioned in a vertical stacked orientation. The transducer is rotated 90 degrees around the centerline of the transverse image of the stacked structure to obtain a longitudinal image while maintaining the vessels in a stacked position. A computerized methodology assists operators to accurately replicate images obtained over several spaced-apart examinations. The methodology utilizes a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time live ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, measurement of vascular dimensions such as carotid arterial IMT and diameter, the coefficient of variation is substantially reduced to values approximating from about 1.0% to about 1.25%. All images contain anatomical landmarks for reproducing probe angulation, including visualization of the carotid bulb, stacking of the jugular vein above the carotid artery, and initial instrumentation settings, used at a baseline measurement are maintained during all follow-up examinations.

Selzer, Robert H.↗

Computer-generated 3D ultrasound images of the carotid artery

A method is under development to measure carotid artery lesions from a computer-generated three-dimensional ultrasound image. For each image, the position of the transducer in six coordinates (x, y, z, azimuth, elevation, and roll) is recorded and used to position each B-mode picture element in its proper spatial position in a three-dimensional memory array. After all B-mode images have been assembled in the memory, the three-dimensional image is filtered and resampled to produce a new series of parallel-plane two-dimensional images from which arterial boundaries are determined using edge tracking methods.

Selzer, Robert H.↗

Effects of cardiac phase on diameter measurements from coronary cineangiograms

The measurement variability of end-diastolic frames is compared with frames taken from the other portions of the cardiac cycle. Two computer measurements, average diameter and minimum, are obtained for every frame of two complete cardiac cycles in angiograms of 20 subjects. Six schemes for sampling frames in various portions of the cardiac cycle are defined and the standard deviation is calculated for pairs of measurements from each scheme. The results suggest that the best strategy for frame selection is to use sequential frames in end-diastole. However, it is noted that if random samples are taken anywhere in the cardiac cycle instead of sequentially in end-diastole, the variability of two vessel edge measures changes from 4.9 percent to 6.3 percent, which is considered to be a small penalty.

Selzer, Robert H.↗

Visualization of Coronary Arteries from Intravenous Angiograms

Under most circumstances, the coronary arteries are not satisfactorily visualized in intravenous angiograms. The objective of this study is to develop computer image enhancement methods that will improve the quality of the latent coronary images to a degree sufficient to detect an obstructive lesion. Such a technique, if successful, could be used as a first step alternative to conventional coronary angiography for individuals with ambiguous noninvasive cardiac tests. The determination of no lesion from the intravenous procedure would relieve the need for the conventional angiogram, while verification of an obstructive lesion could be followed by a conventional angiogram. The nature of the imaging problem and a description of the methods and initial processing results are described in this paper.

Selzer, Robert H.↗