Search NASA⌕ Search

Engineering topics

Sensakovic, William F

Publications and source records attributed to Sensakovic, William F.

Discrete-space versus continuous-space lesion boundary and area definitions

Measurement of the size of anatomic regions of interest in medical images is used to diagnose disease, track growth, and evaluate response to therapy. The discrete nature of medical images allows for both continuous and discrete definitions of region boundary. These definitions may, in turn, support several methods of area calculation that give substantially different quantitative values. This study investigated several boundary definitions (e.g., continuous polygon, internal discrete, and external discrete) and area calculation methods (pixel counting and Green's theorem). These methods were applied to three separate databases: A synthetic image database, the Lung Image Database Consortium database of lung nodules and a database of adrenal gland outlines. Average percent differences in area on the order of 20% were found among the different methods applied to the clinical databases. These results support the idea that inconsistent application of region boundary definition and area calculation may substantially impact measurement accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-dimensional extrapolation methods for texture analysis on CT scans

The application of texture analysis to medical images may require the calculation of texture descriptors on regions of interest (ROIs) that are not completely filled by the tissue under analysis. If a texture descriptor is calculated using such 'deficient' ROIs, the accuracy and computational speed may be adversely affected. This study applied 198 texture descriptors from five texture classes (first-order statistical, second-order statistical, Fourier, fractal, and Laws' filtered) to lung parenchyma ROIs automatically extracted from the thoracic CT scans of ten patients. Statistically significant differences in the values of 138 of these texture descriptors were demonstrated when calculated on deficient ROIs. Three extrapolation methods (mean fill, tiled fill, and CLEAN deconvolution) then were applied to correct the deficient ROIs. Texture descriptor values were calculated and compared for the original, deficient, and corrected ROIs (based on the three extrapolation methods). Each extrapolation method induced statistically significant improvements in texture descriptor accuracy for some subset of texture descriptors. CLEAN deconvolution improved the greatest number of descriptors, demonstrated the best overall accuracy, and created ROIs that were visually most similar to the original ROIs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗