Search NASA⌕ Search

Engineering topics

Shahidehpour, Mohammad

Publications and source records attributed to Shahidehpour, Mohammad.

At least 19 records

Guest Editorial: Special Section on Sustainable Energy for Enhancing Grid Resiliency

Extreme weather threatens lives, disables communities, and devastates energy generation, transmission, and distribution systems. These extreme events are likely to become more frequent or more intense due to climate change. Energy networks have shown significant vulnerability during record hurricanes, deadly heat waves, destructive wildfires, and winter storms in the past few years. Because of the energy transition process, modern power grids will feature a high penetration level of the use of renewable resources. The adoption of renewable energy and the rise of omnidirectional power delivery mean that our energy network is more decentralized than ever. In this new environment, grid operation becomes more complex, and achieving resiliency is more difficult than in the past. Many utilities are seeking the latest technologies to improve energy security and responsiveness to severe events. On the one hand, sustainable energy resources can provide emergency power and assist grid restoration in disastrous events. On the other hand, their volatility, susceptibility, interdependency, and other unique features must be carefully considered when being used for grid resilience enhancement. This special section brings together 22 papers that range from innovative research advances tackling fundamental challenges of achieving more resilient grids to real-world demonstrations of leveraging sustainable energy resources to enhance grid resiliency. These papers can be categorized into three groups.

climate change↗

Optimal Transactive Energy Trading of Electric Vehicle Charging Stations With On-Site PV Generation in Constrained Power Distribution Networks

This paper presents a two-level transactive energy market framework, that enables energy trading among electric vehicle charging stations (EVCSs). At the lower level, the discharging capability of EVs and on-site PV generation are leveraged by individual EVCS for participating in the transactive trading with their peers. Once the lower-level trading is completed, EVCSs trade energy at the upper level through the power grid network managed by the distribution system operator (DSO). The upper-level market is cleared while satisfying the power distribution network constraints. A cooperative game-based model is proposed to model the energy trading among EVCSs. To this end, the asymmetric Nash bargaining method is applied to allocate the grand coalition's payoff to each EVCS at the upper-level market, while a weighted proportional allocation method is used to allocate individual EVCS's payoff to its respective EVs at the lower-level market. In this work, the upper-level market formulation is further decomposed into two subproblems representing an energy scheduling and trading subproblem which maximizes EVCS payoffs, and a bargaining subproblem which allocates EVCS payoffs. The effectiveness of the proposed framework for incentivizing transactive trades among EVs and EVCSs is validated in case studies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Machine Learning-based Reliability Evaluation Model for Integrated Power-Gas Systems

This article proposes a hybrid machine learning method for the reliability evaluation of integrated power-gas systems (IPGS) under the uncertain component failure probability distributions. The Random Forest (RF) method is designed to select important features to solve the insufficient quantity of data and the curse of dimensionality problems. The Extreme Gradient Boosting (XGBoost) regression algorithm is developed to quantify the relationship between the uncertain parameters and reliability metrics. Moreover, a ten-fold cross-validation method is employed to further improve the accuracy of the regression model. Simulation results on three test systems show that the proposed method can achieve high accuracy for the reliability evaluation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Period Active Distribution Network Planning Using Multi-Stage Stochastic Programming and Nested Decomposition by SDDIP

This paper presents a multi-period active distribution network planning (ADNP) with distributed generation (DG). The objective of the proposed ADNP is to minimize the total planning cost, subject to both investment and operation constraints. The paper proposes a multi-stage stochastic optimization model to address DG uncertainties over several periods, in which the decisions are made sequentially by only using the present-stage information. A nested decomposition method is proposed which applies the stochastic dual dynamic integer programming (SDDIP) method to address computational intractabilities of the proposed ADNP approach. The presented numerical results and discussions on a 33-bus distribution system and a large-scale 906-bus system verify the effectiveness of the proposed ADNP method and its solution method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Convex Optimization of Integrated Power-Gas Energy Flow Model With Applications to Probabilistic Energy Flow

Energy flow calculation is a fundamental problem of the integrated power and gas system (IPGS) operation and planning. However, the nonlinear gas flow model introduces major challenges to the energy flow calculation. In this paper, we propose a tractably convex optimization model to solve the energy flow problem in IPGSs. It is demonstrated that the proposed optimization model has the same optimal solution as the original nonlinear steady energy flow model. Also, piecewise linearization is adopted to tightly linearize the nonlinear objective function of the model, which transforms the formulated convex optimization into a linear program one. Thus, the computation complexity of the proposed energy flow model is significantly reduced as compared with the existing methods. In addition, the proposed model can be extended to probabilistic energy flow estimation. Extensive case studies are conducted to validate the effectiveness of the proposed energy flow model using three IPGSs.

42 ENGINEERING↗

Multi-Time Scale Coordinated Control and Scheduling of Inverter-Based TCLs With Variable Wind Generation

To address microgrid tie flow errors caused by wind generation variability, here we propose and develop a multi-time scale coordinated control and scheduling strategy for inverter-based thermostatically controlled loads (TCLs). First, in hour-time scale, inverter-based TCLs with adjusting temperature set-point are modeled as virtual generators to compensate tie flow deviations in the day-ahead plan. Next, in minute-time scale, virtual batteries representing operating behaviors of inverter-based TCLs with frequency control are scheduled determined by the control of virtual generators in hour-time scale. The virtual batteries are scheduled to smooth out tie flow errors corresponding to day-ahead plan and hour-time scale schedules. The multi-time scale control methods are coordinated to employ the response potential of inverter-based TCLs and response curve-based methods are proposed to control inverter-based TCLs considering the customer privacy. The multi-time scale stochastic schedules which are based on response curves of inverter-based TCLs are coordinated to accommodate wind generation variability. Simulation results demonstrate that the microgrid tie flow errors are effectively mitigated by the proposed multi-time scale coordinated control and scheduling of inverter-based TCLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Resilience Enhancement in Typhoons Using a Three-Stage Day-Ahead Unit Commitment

In this work, we propose a three-stage resilient unit commitment model which considers uncertain typhoon paths and line outages to improve the power system resilience against typhoon events. The proposed solution coordinates resources in response to the worst-case scenario for each possible typhoon path. The optimal decision is based on the characterization of the power system schedule into three stages of preventive control, emergency control, and restoration. Preventive control is performed before the typhoon occurs by quickly adjusting the three-stage resilient unit commitment schedule; emergency control is conducted during the typhoon by shedding local loads to meet the power balance, while other control strategies are assumed to be unavailable due to possible interruptions in the communication system; restoration is realized after the typhoon, when resources are optimally dispatched to repair the outages of critical devices and recover the normal operation state of the power system quickly. Considering the typhoon path uncertainty, we have introduced a stochastic model for possible typhoon paths where all possible affected lines along each typhoon path are assumed to be on outage during the typhoon. Accordingly, we explore the strategy for co-optimizing the three stages in unit commitment. The proposed model is tested on the IEEE 118-bus system and the real-world provincial system to verify its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiperiod Distribution System Restoration With Routing Repair Crews, Mobile Electric Vehicles, and Soft-Open-Point Networked Microgrids

This paper proposes a distribution system restoration model which is in response to multiple outages caused by natural disasters. The proposed restoration model includes the coordination of routing repair crews (RRCs), mobile batterycarried vehicles (MBCVs), and networked microgrids (NMGs) formed by soft open points (SOPs). The travel and repair time constraints are modeled for each RRC; travel path and charging strategy are modeled for each MBCV; and the network reconfiguration is developed considering the optimal operation of SOP-based NMGs. Furthermore, the proposed model is presented as a mixedinteger linear program which is solved by an auxiliary induce function based algorithm to reduce the computational complexity. The modified IEEE 33-bus and 69-bus distribution systems are tested with multiple outages. The presented results demonstrate the effectiveness of the proposed model

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hybrid Stochastic-Interval Operation Strategy for Multi-Energy Microgrids

Increasing deployment of distributed energy resources intensifies interactions among electric, gas, heating, and cooling systems. Inherent uncertainties ranging from internal parameters to external inputs also impose significant challenges on system operation. A coordinated scheduling method is, therefore, desired for facilitating efficient operation of multi-energy microgrids under multiple uncertainties. In this paper, a deterministic coordinated scheduling model is developed first with detailed modeling of system dynamics and device parameters to fully characterize complex interactions among multi-energy carriers. Then, a hybrid stochastic-interval method is proposed to account for heterogeneous uncertainties in decisions of operational strategies. Specifically, performance and efficiency uncertainties of distributed energy resources, and injection uncertainty of renewable sources and multienergy demands are characterized by interval-based uncertain operation regions and probability distributions, respectively. A scenario-based two-stage algorithm is developed to solve the problem so that multiple uncertainties are preserved in the entire decision-making process. Moreover, adjustable operational strategies are determined to hedge uncertainty by considering operators’ risk preferences. The validity of the proposed method is verified by comprehensive case studies on a test system.

hybrid stochastic-interval approach↗

Cyber–physical perspective on smart grid design and operation

Emerging computation and communication technologies ubiquitously deployed in smart grids introduce unprecedented opportunities by enabling vigorous development of innovative business models and applications that aim for improving system efficiency, reliability, resiliency, and interoperability. Smart grids are typical cyber–physical systems (CPSs). The heterogeneous and complex nature of smart grids presents significant challenges introduced by the tight coupling of computation, communication, and physical systems. Here, the authors first provide an overview of smart grids from a CPS perspective. Then, the authors discuss the opportunities and challenges in smart grid design and operation. Next, a co‐design framework is introduced and used for designing wide‐area damping controller as one of many CPS applications that can be abstracted from various power system layers. The authors conclude that developing a theoretical modelling framework is critical for understanding and managing the complexity and interoperability of smart grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing and mitigating cybersecurity risks of traffic light systems in smart cities

Intelligent traffic lights are critical cyber‐physical systems that help smart cities to cut road congestion and vehicle emissions. However, they also open a new frontier of cybersecurity. Security researchers have demonstrated ways to compromise the traffic lights to cause potential traffic disruption and public safety degradation. This study aims to raise the public awareness of the cybersecurity issues in traffic light systems. The authors present a bi‐level game‐theoretic framework for assessing cybersecurity risks of traffic light systems, as the first step towards understanding and mitigating the security vulnerabilities. Additionally, they propose a minimax‐regret‐based methodology to guide the deployment of defensive measures in traffic light systems against cyberattacks.

Li, Zhiyi↗

Co-Optimization of Electricity Transmission and Generation Resources for Planning and Policy Analysis: Review of Concepts and Modeling Approaches

The recognition of transmission's interaction with other resources has motivated the development of co-optimization methods to optimize transmission investment while simultaneously considering tradeoffs with investments in electricity supply, demand, and storage resources. For a given set of constraints, co-optimized planning models provide solutions that have lower costs than solutions obtained from decoupled optimization (transmission-only, generation-only, or iterations between them). This paper describes co-optimization and provides an overview of approaches to co-optimizing transmission options, supply-side resources, demand-side resources, and natural gas pipelines. In particular, the paper provides an up-to-date assessment of the present and potential capabilities of existing co-optimization tools, and it discusses needs and challenges for developing advanced co-optimization models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applying DER-CAM for IIT Microgrid Explansion Planning

The Distributed Energy Resources Customer Adoption Model (DER-CAM) is an economic and environmental model of customer DER adoption. This model has been in development at the Lawrence Berkeley National Laboratory since 2000. The objective of the model is to find optimal DER investments while minimizing total energy costs or carbon dioxide (CO2) emissions, or achieving a weighted objective that simultaneously considers both criteria. The Illinois Institute of Technology (IIT) Microgrid project started in August 2008, and the majority of the project was completed in May 2013. IIT Microgrid, funded mostly by a grant from the U.S. Department of Energy as well as State and philanthropic contributions, empowers the campus consumers with the objective of establishing a smart microgrid that is highly reliable, economically viable, environmentally friendly, fuel-efficient, and resilient in extreme circumstances with a self-healing capability. In this project, we apply DER-CAM to study the expansion planning of the IIT Microgrid. First, the load data, environmental data, utility data, and technology data for the IIT Microgrid are gathered and organized to follow the DER-CAM input requirements. Then, DERCAM is applied to study the expansion planning of the IIT Microgrid for different cases, where different objectives in DER-CAM and different utility conditions are tested. Case 1 considers the objective of minimizing energy costs with fixed utility rates and 100% electric utility availability. Case 2 considers the objective of minimizing energy costs with real-time utility rates and 4 emergency weeks when the IIT Microgrid does not have access to the electric utility grid and has to operate in island mode. In Case 3, the utility rates are restored to fixed values and 100% electric utility availability is assumed, but a weighted multi-objective (Obj: a × costs + b × CO2 emissions, where a and b are weights for cost minimization and CO2 emissions minimization) is utilized to consider both energy costs and CO2 emissions. On the basis of the test results, the IIT Microgrid has the potential to benefit from investments in more DER technologies. The current annual energy costs and CO2 emissions for the IIT Microgrid are 6,495.1 k$ and 39,838.5 metric tons, respectively. This represents the baseline for this project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Perfect Power Prototype for Illinois Institute of Technology

Starting in October 2008, Illinois Institute of Technology (IIT), in collaboration with over 20 participating members, led an extensive effort to develop, demonstrate, promote, and commercialize a microgrid system and offer supporting technologies that will achieve Perfect Power at the main campus of IIT. A Perfect Power system, as defined by the Galvin Electricity Initiative (GEI), is a system that cannot fail to meet the electric needs of the individual end-user. The Principle Investigator of this Perfect Power project was Dr. Mohammad Shahidehpour, Director of the Robert W. Galvin Center for Electricity Innovation at IIT. There were six overall objectives of the Perfect Power project: (1) Demonstrate the higher reliability introduced by the microgrid system at IIT; (2) Demonstrate the economics of microgrid operations; (3) Allow for a decrease of fifty percent (50%) of grid electricity load; (4) Create a permanent twenty percent (20%) decrease in peak load from 2007 level; (5) Defer planned substation through load reduction; (6) Offer a distribution system design that can be replicated in urban communities.

24 POWER TRANSMISSION AND DISTRIBUTION↗