Search NASA⌕ Search

Engineering topics

Shao, M.

Publications and source records attributed to Shao, M..

At least 19 records

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The STAR event plane detector

The Event Plane Detector (EPD) is an upgrade detector to the STAR experiment at RHIC, designed to measure the pattern of forward-going charged particles emitted in a high-energy collision between heavy nuclei. It consists of two highly-segmented disks of 1.2-cm-thick scintillator embedded with wavelength-shifting fiber, coupled to silicon photomultipliers and custom electronics. Finally, we describe the general design of the device, its construction, and performance on the bench and in the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-CNR Inverse Synethetic LADAR Imaging Demonstration with Atmospheric Turbulence

An Inverse Synthetic Aperture LADAR (ISAL) system is capable of providing high resolution surface mapping of near Earth objects which is an ability that has gained significant interest for both exploration and hazard assessment. The use of an ISAL system over these long distances often presents the need to operate the optical system in photon-starved conditions. This leads to a necessity to understand the implications of photon and detector noise in the system. Here a Carrier-to-Noise Ratio is derived which is similar to other optical imaging CNR definitions. The CNR value is compared to the quality of experimentally captured images recovered using the Phase Gradient Autofocus technique both with and without the presence of atmospheric turbulence. A minimum return signal CNR for the PGA to work is observed.

ISAL↗

Estimate Low and High Order Wavefront Using P1640 Calibrator Measurements

P1640 high contrast imaging system on the Palomar 200 inch Telescope consists of an apodized-pupil Lyot coronagraph, the PALM-3000 adaptive optics (P3K-AO), and P1640 Calibrator (CAL). Science images are recorded by an integral field spectrograph covering J-H bands for detecting and characterizing stellar companions. With aberrations from atmosphere corrected by the P3K-AO, instrument performance is limited mainly by the quasi-static speckles due to noncommon path wavefront aberrations for the light to propagate to the P3K-AO wavefront sensor and to the coronagraph mask. The non-common path wavefront aberrations are sensed by CAL, which measures the post-coronagraph E-field using interferometry, and can be effectively corrected by offsetting the P3K-AO deformable mirror target position accordingly. Previously, we have demonstrated using CAL measurements to correct high order wavefront aberrations, which is directly connected to the static speckles in the image plane. Low order wavefront, on the other hand, usually of larger amplitudes, causes light to leak through the coronagraph making the whole image plane brighter. Knowledge error in low order wavefront aberrations can also affect the estimation of the high order wavefront. Even though, CAL is designed to sense efficiently high order wavefront aberrations, the low order wavefront front can be inferred with less sensitivity. Here, we describe our method for estimating both low and high order wavefront aberrations using CAL measurements by propagating the post-coronagraph E-field to a pupil before the coronagraph. We present the results from applying this method to both simulated and experiment data.

aberrations↗