Design and optimization of THz coupling in zirconia MAS rotors for dynamic nuclear polarization NMR
Not Available
Engineering topics
Publications and source records attributed to Shapiro, Michael A..
Not Available
A 250 GHz quasi-optical ring resonator consisting of an input coupler and three mirrors has been designed and tested. A low-loss silicon wafer in the ring provides output coupling of the stored power when irradiated by a pulse from a 532 nm laser. The ring created 5.8 ns, 268 mW output power pulses when excited by a 17 mW, 250 GHz continuously operating input source, achieving a power gain of 16. In a fully tuned ring, higher gain is achievable. If the ring was used with a pulsed input source having a pulse length of several times the fill time, the ring could be used as an efficient pulse compressor with similar high gain. The resonator has a wide range of applications, including, at low power, spectroscopy and, at high power, testing of accelerator structures and materials.
The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30 deg/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.
A 17 GHz single cell, standing wave, copper accelerator structure with an axisymmetric elliptical central cell sidewall was tested for internal and downstream dark current as a function of gradient up to 93 MV/m. The elliptical sidewall was predicted to suppress the internal dark current and the lower order multipactor modes as compared with a previously tested structure having a straight sidewall. During the conditioning phase of the elliptical sidewall structure, strong internal dark current generated by an N = 1 multipactor mode was observed at gradients in the 10 to 20 MV/m range. After conditioning with 2.2x10^5 pulses to 93 MV/m, the N = 1 mode was completely suppressed and no multipactor resonances were observed. The internal dark current was reduced to a comparatively low level, much smaller than in the previously studied, straight sidewall structure, in good agreement with simulations. The energy spectrum of the electrons colliding with the sidewall was measured using an isolated side dark current monitor and a bias voltage. As the conditioning progressed, the electron energy spectrum showed an increase in the concentration of lower energy electrons, also in good agreement with simulations. Studies of internal dark current may help to understand the rf conditioning and ultimate performance of high gradient accelerator structures.
Metamaterials (MTMs) are structured materials with subwavelength features that can be engineered to have some unique properties not found in nature, such as negative refractive index, reversed Doppler effect, and reversed Cherenkov radiation. Based on these novel MTMs, several important research groups have made great attempts to develop novel MTM-inspired vacuum electron devices (VEDs) and accelerators. Just as solid-state power devices are innovated by incessant emerging of new semiconductor materials, VEDs can also be inspired by MTMs to have very remarkable advantages, such as smaller size, higher power, higher efficiency, and/or larger gain relative to conventional VEDs, such as traveling-wave tubes, backward-wave oscillators, and klystrons. Similarly, relative to conventional accelerators, MTM-inspired accelerators have obvious advantages, such as smaller size and higher accelerating gradient. Furthermore, MTM-inspired devices have promising applications in areas such as radar, communication, electronic warfare, microwave heating, and imaging.
The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.
In this paper, we present an experimental study of coherent high-power wakefield generation in a metamaterial (MTM) structure at 11.7 GHz by 65 MeV electron bunch trains at the Argonne Wakefield Accelerator (AWA), following a previous experiment, the Stage-I experiment, at the AWA. Both the Stage-II experiment, reported in this paper, and the Stage-I experiment were conducted using MTM structures, which are all-metal periodic structures with the period being much smaller than the wavelength. Differences between the two experiments include (1) structure length (Stage-I 8 cm and Stage-II 20 cm); (2) number of bunches used to excite the structure (Stage-I with two bunches, up to 85 nC of total charge; Stage-II with eight bunches, up to 224 nC of total charge); and (3) highest peak power measured (Stage-I 80 MW in a 2 ns pulse and Stage-II 380 MW in a 10 ns pulse). High-power radio frequency pulses were generated by reversed Cherenkov radiation of the electron beam due to the negative group velocity in the MTM structures. Because the radiation is coherent, a train of bunches with a proper spacing can build up to achieve a high peak power. The observed output power levels are very promising for future applications in direct collinear wakefield acceleration or in transfer to a second accelerator for two-beam acceleration.
The elliptical polarization produced by a pair of sinusoidally profiled miter-bend grating polarizers has been measured experimentally and found to be in excellent agreement with theory. The polarizers were designed to be used at 170 GHz in the miter bends of a 63.5 mm corrugated metallic waveguide for creating the arbitrary elliptically polarized microwave beam needed for electron cyclotron resonance heating of plasma. Using a vector network analyzer to generate a linearly polarized HE11 incident mode, each polarizer was individually tested to measure the rotation α and ellipticity β of the elliptically polarized reflected microwave beam as a function of the grating rotation angle. The grating polarizers were then tested together to measure the elliptical polarization as a function of the angles of the combination of the two polarizers arranged sequentially on the transmission line. The map of the ellipticity versus grating angles agreed very well with numerical simulations using high-frequency structure simulator. Numerical simulations show that up to eight combinations of rotation angles of the two grating polarizers can provide the same ellipticity but with the varying ohmic loss, thus allowing the choice of settings to minimize the ohmic loss, a necessary consideration to minimize heating effects in megawatt power level systems.
Not Available