Comparison of Target Registration Errors for Multiple Image-Guided Techniques in Accelerated Partial Breast Irradiation

Purpose: External beam accelerated partial breast irradiation requires accurate localization of the target volume for each treatment fraction. Using the concept of target registration error (TRE), the performance of several methods of target localization was compared. Methods and Materials: Twelve patients who underwent external beam accelerated partial breast irradiation were included in this study. TRE was quantified for four methods of image guidance: standard laser-based setup, kilovoltage imaging of the chest wall, kilovoltage imaging of surgically implanted clips, and three-dimensional surface imaging of the breast. The use of a reference surface created from a free-breathing computed tomography scan and a reference surface directly captured with three-dimensional video imaging were compared. The effects of respiratory motion were also considered, and gating was used for 8 of 12 patients. Results: The median value of the TRE for the laser, chest wall, and clip alignment was 7.1 mm (n = 94), 5.4 mm (n = 81), and 2.4 mm (n = 93), respectively. The median TRE for gated surface imaging based on the first fraction reference surface was 3.2 mm (n = 49), and the TRE for gated surface imaging using the computed tomography-based reference surface was 4.9 mm (n = 56). The TRE for nongated surface imaging using the first fraction reference surface was 6.2 mm (n = 25). Conclusions: The TRE of surface imaging using a reference surface directly captured with three-dimensional video and the TRE for clip-based setup were within 1 mm. Gated capture is important for surface imaging to reduce the effects of respiratory motion in accelerated partial breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric impact of motion in free-breathing and gated lung radiotherapy: A 4D Monte Carlo study of intrafraction and interfraction effects

The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric effects were studied considering the breathing pattern of three patients monitored during the course of their treatment and an in-house developed 4D Monte Carlo framework. Imaging data were taken in free-breathing and in cine mode for both 3D and 4D acquisition. Treatment planning for IMRT delivery was done based on the free-breathing data with the CORVUS (North American Scientific, Chatsworth, CA) planning system. The dose distributions as a function of phase in the breathing cycle were combined using deformable image registration. The study focused on (a) assessing the accuracy of the CORVUS pencil beam algorithm with Monte Carlo dose calculation in the lung, (b) evaluating the dosimetric effect of motion on the individual breathing phases of the respiratory cycle, and (c) assessing intrafraction and interfraction motion effects during free-breathing or gated radiotherapy. The comparison between (a) the planning system and the Monte Carlo system shows that the pencil beam algorithm underestimates the dose in low-density regions, such as lung tissue, and overestimates the dose in high-density regions, such as bone, by 5% or more of the prescribed dose (corresponding to approximately 3-5 Gy for the cases considered). For the patients studied this could have a significant impact on the dose volume histograms for the target structures depending on the margin added to the clinical target volume (CTV) to produce either the planning target (PTV) or internal target volume (ITV). The dose differences between (b) phases in the breathing cycle and the free-breathing case were shown to be negligible for all phases except for the inhale phase, where an underdosage of the tumor by as much as 9.3 Gy relative to the free-breathing was observed. The large difference was due to breathing-induced motion/deformation affecting the soft/lung tissue density and motion of the bone structures (such as the rib cage) in and out of the beam. Intrafraction and interfraction dosimetric differences between (c) free-breathing and gated delivery were found to be small. However, more significant dosimetric differences, of the order of 3%-5%, were observed between the dose calculations based on static CT (3DCT) and the ones based on time-resolved CT (4DCT). These differences are a consequence of the larger contribution of the inhale phase in the 3DCT data than in the 4DCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗