Venting through multiple-layer insulation on Space Station Freedom. I - Flow rate testing and analysis

A test was conducted to determine the venting characteristics of multiple-layer insulation (MLI). It involved forcing air through four samples of MLI components and measuring the pressure differences and flow rates. Results from this test have been used to create a mathematical model of the flow through the MLI components. This model is used in a companion paper to predict the results of a second test and the venting behavior of MLI on the Space Station.

Sharp, Jeffrey B.↗

Venting through multiple-layer insulation on Space Station Freedom. II - Ascent rate pressure chamber testing

A test was conducted to determine the venting characteristics of the multiple-layer insulation (MLI) to be installed on the Space Station Freedom (SSF). A full MLI blanket with inter-blanket joints was installed onto a model of a section of the SSF pressure wall, support structure, and debris shield. Data were taken from this test and were used to predict the venting of the actual Space Station pressure-wall/MLI/debris-shield assemply during launch and possible re-entry. It was found that the pressure differences across the debris shields and MLI blankets were well within the specified limits in all cases.